scholarly journals The Influence of heat treatment in orthodontic arches made of stainless steel wire

2000 ◽  
Vol 3 (3) ◽  
pp. 97-98 ◽  
Author(s):  
R.S. de Biasi ◽  
A.C.O. Ruela ◽  
C.N. Elias ◽  
O. Chevitarese
1973 ◽  
Vol 52 (6) ◽  
pp. 1171-1175 ◽  
Author(s):  
Michael R. Marcotte

With the use of springback and recovery as dependent variables, the effects of time and temperature of stress relief heat treatment of stainless steel wire were studied. Stainless steel springs exposed to a stress relief heat treatment of 750 F for 11 minutes appear to have significantly improved spring properties.


2021 ◽  
Vol 1942 (1) ◽  
pp. 012102
Author(s):  
M A Kaplan ◽  
A Yu Ivannikov ◽  
A D Gorbenko ◽  
A V Mikhailova ◽  
A A Kirsankin ◽  
...  

1991 ◽  
Vol 49 (10) ◽  
pp. 1074-1078
Author(s):  
Richard H. Haug ◽  
Jon P. Bradrick ◽  
Marilyn Su

2013 ◽  
Vol 746 ◽  
pp. 394-399
Author(s):  
Niwat Anuwongnukroh ◽  
Yosdhorn Chuankrerkkul ◽  
Surachai Dechkunakorn ◽  
Pornkiat Churnjitapirom ◽  
Theeralaksna Suddhasthira

The archwire is generally used in fixed appliances for orthodontic treatment to correct dental malocclusion. However, it is interesting to know whether general purpose stainless steel wire could replace commercial orthodontic archwire in orthodontic practice for economic reasons. The purpose of this study was to determine the bending properties of general purpose stainless steel wire compared with commercial orthodontic stainless steel wires after forming as an archwire for orthodontic use. The samples used in this study were 90 general purpose and 45 commercial (Highland) round stainless steel wires in 0.016, 0.018, and 0.020 sizes (30 general purpose and 15 commercial wires for each size). All 15 general purpose stainless steel wires with different sizes were formed into orthodontic archwire with a Universal Testing Machine. All samples were tested (three-point bending test) for mechanical properties. The results showed no significant difference between general purpose and commercial orthodontic wires in size 0.016 for 0.1 mm offset bending force, 0.2% yield strength, and springback. Although many mechanical properties of general purpose wires differed from commercial wires, their values conformed to other previous studies within the range of clinical acceptance. In conclusion, orthodontic formed general purpose round stainless steel wires had statistically different (p <0.05) mechanical properties from commercial orthodontic stainless steel wires (Highland) but the mechanical properties were acceptable to use in orthodontic treatment.


Sign in / Sign up

Export Citation Format

Share Document