scholarly journals Is nuclear medicine really safe?

2002 ◽  
Vol 45 (spe) ◽  
pp. 115-118
Author(s):  
Nicole Colas-Linhart

In nuclear medicine, radiation absorbed dose estimates calculated by standard models at the whole body or organ are very low. At cellular level, however, the heterogeneity of radionuclide distributions of radiation dose patterns may be significant. We present here absorbed doses at cellular level and evaluate their possible impact on the usually assumed risk/benefit relationships in nuclear medicine studies. The absorbed dose values calculated are surprisingly high, and are difficult to interpret. In the present study, we show calculated doses at the cellular level and discuss possible biological consequences, for two radiopharmaceuticals labelled with technetium-99m: human serum albumin microspheres used for pulmonary scintigrapies and HMPAO used to labelled leukocytes.

1974 ◽  
Vol 13 (02) ◽  
pp. 193-206
Author(s):  
L. Conte ◽  
L. Mombelli ◽  
A. Vanoli

SummaryWe have put forward a method to be used in the field of nuclear medicine, for calculating internally absorbed doses in patients. The simplicity and flexibility of this method allow one to make a rapid estimation of risk both to the individual and to the population. In order to calculate the absorbed doses we based our procedure on the concept of the mean absorbed fraction, taking into account anatomical and functional variability which is highly important in the calculation of internal doses in children. With this aim in mind we prepared tables which take into consideration anatomical differences and which permit the calculation of the mean absorbed doses in the whole body, in the organs accumulating radioactivity, in the gonads and in the marrow; all this for those radionuclides most widely used in nuclear medicine. By comparing our results with dose obtained from the use of M.I.R.D.'s method it can be seen that when the errors inherent in these types of calculation are taken into account, the results of both methods are in close agreement.


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document