scholarly journals Diagnostic ability of barrett's index to detect dysthyroid optic neuropathy using multidetector computed tomography

Clinics ◽  
2008 ◽  
Vol 63 (3) ◽  
pp. 301-306 ◽  
Author(s):  
Mário L. R. Monteiro ◽  
Allan C. P. Gonçalves ◽  
Carla T. M. Silva ◽  
Janete P. Moura ◽  
Carolina S. Ribeiro ◽  
...  
2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Zhihong Deng ◽  
Lu Chen ◽  
Jia Tan ◽  
Sha Wang ◽  
Dan Liu ◽  
...  

Background. Dysthyroid optic neuropathy (DON) is one of the most serious vision-threatening complications of thyroid eye disease (TED); however, accurate and established diagnostic tools for DON are yet lacking. The present study was aimed at identifying new diagnostic factors for the accurate diagnosis of DON. Methods. This retrospective cross-sectional study included 25 TED patients (50 eyes) with enlarged extraocular muscles, no previous anti-inflammatory therapy, and the absence of other vision-affecting diseases between May 2017 and August 2019. Baseline data, such as gender, age, ophthalmological history, thyroid disease and management, TED history including clinical features, management, and long-term results, ophthalmological examinations, serology examinations, and single-photon emission computed tomography/computed tomography (SPECT/CT) results, were extracted. The diagnostic criteria were as follows: (1) best-corrected visual acuity (BCVA) loss coexisting with either of the following—increased latency or reduction of amplitude on visual evoked potential (VEP), impaired color vision, visual field defects, contrast sensitivity impairment, and optic disk swelling—and (2) Barret t ’ s   index ≥ 60 % in CT. Univariate and multivariate logistic regression analyses assessed the differences in age, gender, eyes, medical history, clinical activity, thyroid hormone and antibodies, uptake ratio (UR) of extraocular muscles in SPECT/CT, and volumetric orbital apex crowding index (VACI) using the generalized estimation equation. Consequently, the receiver operating characteristic curve (ROC) of the significant factors was constructed. Results. Univariate analysis revealed significant differences in the clinical activity, free triiodothyronine (FT3), free thyroxine (FT4), thyrotrophin receptor antibody (TRAb) levels, the UR of superior and medial rectus, and VACI between DON and TED (without DON) groups. Multivariate regression analysis revealed that TRAb and VACI were significantly different. ROC analysis showed that the univariate models of TRAb or VACI and the multivariate model were effective indicators of DON, while the multivariate model had the highest area under the ROC curve. Conclusion. A combination of TRAb and VACI is an effective indicator for DON.


Orbit ◽  
2019 ◽  
Vol 39 (2) ◽  
pp. 77-83
Author(s):  
Victoria S. Starks ◽  
Katherine L. Reinshagen ◽  
Nahyoung G. Lee ◽  
Suzanne K. Freitag

Clinics ◽  
2012 ◽  
Vol 67 (8) ◽  
pp. 891-896 ◽  
Author(s):  
AC Goncalves ◽  
LN Silva ◽  
EM Gebrim ◽  
S Matayoshi ◽  
ML Monteiro

2008 ◽  
Vol 58 (3) ◽  
pp. 277
Author(s):  
Ji Sang Park ◽  
Seong Jin Park ◽  
Hae Kyung Lee ◽  
Boem Ha Yi ◽  
Hyun Sook Hong ◽  
...  

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2010 ◽  
Vol 13 (3) ◽  
pp. E198-E199
Author(s):  
Yi-Chang Lin ◽  
Yi-Ting Tsai ◽  
Chih-Yuan Lin ◽  
Chung-Yi Lee ◽  
Gou-Jieng Hong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document