AN EXPERIMENTAL INVESTIGATION OF THE AIR-SIDE PERFORMANCE OF FIN-AND-TUBE HEAT EXCHANGERS HAVING SLIT FINS

2015 ◽  
Vol 22 (1) ◽  
pp. 67-88 ◽  
Author(s):  
Nae-Hyun Kim ◽  
Honggi Cho
1997 ◽  
Vol 119 (2) ◽  
pp. 348-356 ◽  
Author(s):  
J. L. Hoke ◽  
A. M. Clausing ◽  
T. D. Swofford

An experimental investigation of the air-side convective heat transfer from wire-on-tube heat exchangers is described. The study is motivated by the desire to predict the performance, in a forced flow, of the steel wire-on-tube condensers used in most refrigerators. Previous investigations of wire-on-tube heat exchangers in a forced flow have not been reported in the literature. The many geometrical parameters (wire diameter, tube diameter, wire pitch, tube pitch, etc.), the complex conductive paths in the heat exchanger, and the importance of buoyant forces in a portion of the velocity regime of interest make the study a formidable one. A key to the successful correlation of the experimental results is a definition of the convective heat transfer coefficient, hw, that accounts for the temperature gradients in the wires as well as the vast difference in the two key characteristic lengths—the tube and wire diameters. Although this definition results in the need to solve a transcendental equation in order to obtain hw from the experimental data, the use of the resulting empirical correlation is straightforward. The complex influence of the mixed convection regime on the heat transfer from wire-on-tube heat exchangers is shown, as well as the effects of air velocity and the angle of attack. The study covers a velocity range of 0 to 2 m/s (the Reynolds number based on wire diameter extends to 200) and angles of attack varying from 0 deg (horizontal coils) to ±90 deg. Heat transfer data from seven different wire-on-tube heat exchangers are correlated so that 95 percent of the data below a Richardson number of 0.004, based on the wire diameter, lie within ±16.7 percent of the proposed correlation.


2018 ◽  
Vol 245 ◽  
pp. 07002 ◽  
Author(s):  
Vladimir Davletbaev ◽  
Natalia Rydalina ◽  
Elena Antonova

We study heat exchangers at the experimental setup aiming at the energy-saving. The feature of this heat exchange process is of the fact that the working medium is a porous metal. The pores are filled with freon and operation of the refrigeration unit condenser is studied. The scheme of the experimental setup and experiment methodology are given. The results of the experiment and its processing are also presented.


Sign in / Sign up

Export Citation Format

Share Document