scholarly journals Analysis of the thermal load of cooling systems refrigeration vehicles

Author(s):  
U.D. Rumantcev ◽  
F.O. Veselkin
Keyword(s):  
Author(s):  
Yongmei Xu ◽  
Jingru Zhang ◽  
Yuhui Deng ◽  
Lan Du ◽  
Rong Jiao

Given the explosive growth of data, scalability and fault tolerance have become a fundamental challenge for data center network structures. Temperature in data centers significantly affects the failure ratio of high-speed network devices. Various types of air distribution schemes influence the temperature of network equipment differently, and the cooling cost in data centers dominates the overall energy cost. On the basis of the energy efficiency of cooling systems, this study analyzes and compares the thermal load distribution in the enclosure of standard and non-standard data centers by considering the effects of the external environment. Analysis results demonstrate that the external environment significantly affects the thermal load of non-standard data centers. By leveraging on the air temperature outside data centers and on the inlet/outlet of IT equipment, the air temperature and return air temperature of air conditioning are calculated when performing hot and cold aisle containment. The calculations indicate that sealing an appropriate aisle (hot or cold aisle) can significantly reduce the energy consumption of cooling systems in terms of the external air temperature outside data centers. Furthermore, if the air temperature outside data centers is higher than the temperature at the inlet of IT equipment, sealing the cold aisle outperforms sealing the hot aisle. By contrast, the aisle to be sealed depends on the energy efficiency ratio of the air conditioning.


2021 ◽  
Vol 2119 (1) ◽  
pp. 012129
Author(s):  
O A Kabov ◽  
Ya V Zubavichus ◽  
K E Cooper ◽  
M V Pukhovoy ◽  
V V Vinokurov ◽  
...  

Abstract Construction of the 4+ generation Siberian circular photon source (SKIF synchrotron) has started in Novosibirsk. It will initially be equipped with six research workstations. For two stations, synchrotron radiation is generated by superconducting wigglers, whose radiation power approaches 49 kW, and the power density on the axis is 92 kW/mrad2. Most of the optical devices of the stations operate in a vacuum. The high energy density of the synchrotron beamline and the requirements for the values of thermal deformations lead to difficult conditions for the thermal management of optical elements. The article provides an overview of the applied and promising cooling systems; an example of a 3D calculation of a thermal diamond filter of workstation 1-5 is given, the limit for the thermal load of the filter, at which the temperature of the diamond plate will not exceed 600 °C, is estimated.


2013 ◽  
Vol 44 (1) ◽  
pp. 39-54
Author(s):  
A. Wehlmann ◽  
W. Hater ◽  
F. Wolf ◽  
R. Lunkenheimer ◽  
C. Foret ◽  
...  

2007 ◽  
Vol 23 (5) ◽  
pp. 546-555 ◽  
Author(s):  
R. Burgos ◽  
L.J. Odens ◽  
R.J. Collier ◽  
L.H. Baumgard ◽  
M.J. VanBaale

2009 ◽  
Vol 40 (4) ◽  
pp. 293-304 ◽  
Author(s):  
I. Cherednichenko ◽  
E. Khodak ◽  
A. I. Kirillov ◽  
N. Zabelin

PIERS Online ◽  
2008 ◽  
Vol 4 (2) ◽  
pp. 176-180
Author(s):  
Shu-Fang Liu ◽  
Shao-Dong Liu

Sign in / Sign up

Export Citation Format

Share Document