scholarly journals 18F-fluoroethyltyrozine positron emission tomography combined with computed tomography and computed tomography perfusion in complex diagnostic of glial brain tumors

2020 ◽  
Vol 9 (4) ◽  
pp. 24-31 ◽  
Author(s):  
A. I. Pronin ◽  
M. B. Dolgushin ◽  
D. V. Sashin ◽  
N. A. Meshcheryakova ◽  
O. D. Ryzhova ◽  
...  

The study objective is to evaluate the diagnostic capabilities of complex method based on the use of 18 F-fluoroethyltyrozine positron emission tomography (PET) combined with computed tomography (CT) and CT perfusion in the differential diagnosis of glial brain tumors.Materials and methods. One hundred and two patients with glial brain tumors were included in the study. Depending on the degree of malignancy patients were divided into 2 groups: group 1–38 (37.26 %) patients with grade I–II tumors; group 2–64 (62.74 %) patients with grade III–IV tumors. Perfusion CT was performed in 20 (52.6 %) patients from the group with grade I–II tumors and 37 (57.8 %) patients from the group with grade III–IV gliomas. The sensitivity and specificity of such indicators as the maximum standardized uptake value (maxSUV) and the tumor to brain ratio (TBR), in combination with CT perfusion indicators (cerebral blood flow (CBF), cerebral blood volume (CBV), vascular permeability (FED) were studied.Results. The highest diagnostic accuracy was demonstrated by the following parameters: maxSUV 1 (sensitivity and specificity 81 and 82 %, threshold value 2.51, AUC 0.87); TBR 1 (sensitivity and specificity 90.6 and 81.6 %, threshold value 2.07, AUC 0.89). The comprehensive evaluation of CT perfusion and 18 F-fluoroethyltyrozine PET / CT parameters: sensitivity and specificity of TBR 1 + CBF – 97.1 and 94.4 %, respectively; TBR 1 + CBV – 96.6 and 94.4 %, respectively; TBR 1 + FED – 94.6 and 92.3 %, respectively.Conclusion. According to results of obtained analysis, an increase in diagnostic accuracy was revealed for all studied parameters with complex use of two methods – 18 F-fluoroethyltyrozine PET / CT and CT perfusion, in differential diagnosis of glial brain tumors.

2010 ◽  
Vol 28 (25) ◽  
pp. 3973-3978 ◽  
Author(s):  
Andrea B. Apolo ◽  
Jamie Riches ◽  
Heiko Schöder ◽  
Oguz Akin ◽  
Alisa Trout ◽  
...  

Purpose Fluorine-18 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) has been approved for imaging in many malignancies but not for bladder cancer. This study investigated the value of FDG-PET/CT imaging in the management of patients with advanced bladder cancer. Patients and Methods Between May 2006 and February 2008, 57 patients with bladder cancer at our center underwent FDG-PET/CT after CT (n = 52) or magnetic resonance imaging (MRI; n = 5). The accuracy of FDG-PET/CT was assessed using both organ-based and patient-based analyses. FDG-PET/CT findings were validated by either biopsy or serial CT/MRI. Clinician questionnaires performed before and after FDG-PET/CT assessed whether those scan results affected management. Results One hundred thirty-five individual lesions were evaluable in 47 patients for the organ-based analysis. Overall sensitivity and specificity were 87% (95% CI, 76% to 94%) and 88% (95% CI, 78% to 95%), respectively. In the patient-based analysis, malignant disease was correctly diagnosed in 25 of 31 patients, resulting in a sensitivity of 81% (95% CI, 63% to 93%). FDG-PET/CT was negative in 15 of 16 patients without malignant lesions for a specificity of 94% (95% CI, 71% to 100%). Pre- and post-PET surveys revealed that FDG-PET/CT detected more malignant disease than conventional CT/MRI in 40% of patients. Post-PET surveys showed that clinicians changed their planned management in 68% of patients based on the FDG-PET/CT results. Conclusion FDG-PET/CT has excellent sensitivity and specificity in the detection of metastatic bladder cancer and provides additional diagnostic information that enhances clinical management more than CT/MRI alone. FDG-PET/CT scans may provide better accuracy in clinical information for directing therapy.


2011 ◽  
Vol 14 (5) ◽  
pp. 283 ◽  
Author(s):  
Andre Plass ◽  
Maximilian Y. Emmert ◽  
Oliver Gaemperli ◽  
Hatem Alkadhi ◽  
Philipp Kaufmann ◽  
...  

<p><b>Background:</b> We evaluated how comprehensive assessment of coronary artery lesions and their hemodynamic relevance by means of hybrid positron emission tomography (PET) and computed tomography (CT) imaging would affect decision-making in coronary artery bypass surgery (CABG), compared with using invasive coronary angiography (ICA) alone.</p><p><b>Methods:</b> After undergoing ICA, 27 patients (21 men and 6 women; mean SD age, 66 � 10 years) planned for cardiac surgery were scheduled for myocardial perfusion stress/rest evaluation with [13N]ammonia PET and CT coronary angiography. Only ICA was available to the surgeon. Postoperatively, the performed CABG was compared with the hypothetical strategy based on hybrid PET/CT findings (regional coronary flow reserve [CFR], myocardial perfusion defects). Procedures included CABG (n = 18) alone, CABG combined with valve replacement (n = 6), and CABG combined with isolated valve replacement (n = 3). A total of 56 bypass grafts (28 venous and 28 arterial) and 66 distal anastomoses were placed.</p><p><b>Results:</b> CT evaluation showed 93% concordance (66/71) with ICA regarding significant stenoses, with sensitivity, specificity, positive predictive value, and negative predictive value of 93.1%, 98.7%, 94.4%, and 98.4%, respectively. In the PET scan, 16 patients had 1 ischemic region, and 12 patients had 1 scar region, including 5 patients who presented with mixed conditions (scar and ischemia). One patient had a completely normal myocardium. Compared with the performed surgery, PET/CT fusion evaluation showed that of the performed anastomoses, 48% had documented ischemia (with a CFR <2 in 86%), 38% were nonischemic (although a CFR value <2 was found in 78%), and 14% had scar tissue (fixed perfusion defect).</p><p><b>Conclusions:</b> Although <50% of bypasses were placed to areas with myocardial ischemia, the CFR was low in the majority of nonischemic regions, a finding that may have important prognostic relevance. PET/CT fusion imaging could potentially influence planning for CABG and provide incremental prognostic information.</p>


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 304
Author(s):  
Giuseppina Biscontini ◽  
Cinzia Romagnolo ◽  
Chiara Cottignoli ◽  
Andrea Palucci ◽  
Fabio Massimo Fringuelli ◽  
...  

Background: to explore the diagnostic accuracy of 18F-Fluciclovine positron-emission tomography (PET) in prostate cancer (PCa), considering both primary staging prior to radical therapy, biochemical recurrence, and advanced setting. Methods: A systematic web search through Embase and Medline was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Studies performed from 2011 to 2020 were evaluated. The terms used were “PET” or “positron emission tomography” or “positron emission tomography/computed tomography” or “PET/CT” or “positron emission tomography-computed tomography” or “PET-CT” and “Fluciclovine” or “FACBC” and “prostatic neoplasms” or “prostate cancer” or “prostate carcinoma”. Only studies reporting about true positive (TP), true negative (TN), false positive (FP) and false negative (FN) findings of 18F-fluciclovine PET were considered eligible. Results: Fifteen out of 283 studies, and 697 patients, were included in the final analysis. The pooled sensitivity for 18F-Fluciclovine PET/CT for diagnosis of primary PCa was 0.83 (95% CI: 0.80–0.86), the specificity of 0.77 (95% CI: 0.74–0.80). The pooled sensitivity for preoperative LN staging was 0.57 (95% CI: 0.39–0.73) and specificity of 0.99 (95% CI: 0.94–1.00). The pooled sensitivity for the overall detection of recurrence in relapsed patients was 0.68 (95% CI: 0.63–0.73), and specificity of 0.68 (95% CI: 0.60–0.75). Conclusion: This meta-analysis showed promising results in term of sensitivity and specificity for 18F-Fluciclovine PET/CT to stage the primary lesion and in the assessment of nodal metastases, and for the detection of PCa locations in the recurrent setting. However, the limited number of studies and the broad heterogeneity in the selected cohorts and in different investigation protocols are limitation affecting the strength of these results.


Author(s):  
Farnoosh Larti ◽  
Mohammad Amin Khadembashiri ◽  
Mehrshad Abbasi ◽  
Alborz Sherafati

Abstract Background Diagnosis of aortic graft infection is challenging, and delayed diagnosis is associated with poor prognosis. Positron emission tomography/computed tomography (PET/CT) has improved diagnostic accuracy. Case summary A patient with a history of congenital heart disease was admitted due to fever. He had a history of four cardiac surgeries, including the Bentall procedure for endocarditis. Blood cultures were negative. A semi-mobile mass was detected in the distal portion of the aortic tube graft in echocardiography. PET/CT scan was used to confirm tube graft infection and to support proceeding to cardiac surgery. Discussion Using multimodality imaging, including PET/CT scan in combination with echocardiography, can improve diagnostic accuracy for the detection of aortic tube graft infection, infection of prosthetic valves, or intra-cardiac devices, especially in high-risk surgical cases.


2021 ◽  
Vol 5 (1) ◽  
pp. 1151-1160
Author(s):  
A.S. Lukashevich ◽  

Purpose. The purpose of the article is to evaluate the diagnostic significance of positron emission tomography / computed tomography with 18F -fluorodeoxyglucose (18F -FDG PET/CT) for the diagnosis of prosthetic endocarditis. Methods of research. The study included 82 patients with suspected prosthetic endocarditis in accordance with the criteria proposed by Duke University [1-5]. The patients received hospital treatment at the State Institution RSPC "Cardiology" from January 2016 to March 2021. The study was of a prospective, non-randomized, single-center cohort design. The duration of the monitor period was 12 months from the moment of patients’ inclusion in the study. Whole-body positron emission tomography / computed tomography (PET/CT) examinations were performed in 82 patients. 27 patients were selected for surgical treatment. Conservative treatment group included 16 patients. 27 patients were selected into the observation group, they were suspected to have prosthetic heart valve infection in the primary referral and underwent PET/CT scanning, according to which the diagnosis of prosthetic endocarditis was excluded. The event under the study did not develop in this group during the year of observation. Results and conclusion. The history of infective endocarditis was not statistically significant and did not increase the risk of developing prosthetic endocarditis in the sample presented. The Duke criteria are less reliable in establishing the diagnosis of prosthetic endocarditis. The median number of days from the date of the first prosthesis implantation to the onset of prosthetic endocarditis was about 4 years. This study revealed that the development of the infectious process in the area of the prosthesis was noted in a more distant postoperative period compared to literature data. Histological confirmation of infection was noted in 100% (27 patients) of cases in reoperated patients. The presence of a more formidable complication such as valve ring abscess located mainly in the projection of the aortic valve ring was quite common in both groups. Presepsin and Interleukin-6 have a statistically significant (U = 394,50 p = 0,01 and U = 94,50 p = 0.004) value in the prognosis of prosthetic endocarditis. Considering the data obtained from ROC analysis, it can be said that the cut-off point at which it is possible to diagnose prosthetic endocarditis based on PETCT is 2.85. The presented methods for the interpretation of whole-body FDG-PET/CT images of patients with suspected infectious complications after cardiac surgery, as well as with the presence of prosthetic endocarditis, show high sensitivity and specificity.


Sign in / Sign up

Export Citation Format

Share Document