scholarly journals Solid-phase microextraction of benzophenones coupled with gas chromatography analysis

2016 ◽  
Vol 4 (2) ◽  
pp. 55-62
Author(s):  
Valentyna Levchyk ◽  
M. Zui

In this study, solid-phase microextraction method combines with gas chromatography-flame ionization detector. The proposed method is used for the preconcentration of some benzophenones. Influence of different factors on the efficiency of extraction is described in detail. The analytical procedure was optimized for fiber coating selection, extraction time, temperature, sample pH, ionic strength. For all benzophenones, the highest enrichment factors were achieved using carboxen/polydimethylsiloxane/divinylbenzene fibre immersed directly into the water samples, containing 100 mg/mL of sodium chloride, at room temperature. The optimum pH range is 5.0 – 7.0. The relative standard deviations (RSDs) were from 1.3 to 10.0 % (n = 3). The method was applied to the determination of benzophenone, benzophenone-3, 2-hydroxybenzophenone in the lake water and urine.

2008 ◽  
Vol 19 (6) ◽  
pp. 1201-1206 ◽  
Author(s):  
Diego C. Netto ◽  
Rafael M. Reis ◽  
Camila B. Mendes ◽  
Paulo C. F. L. Gomes ◽  
Isarita Martins ◽  
...  

2011 ◽  
Vol 91 (13) ◽  
pp. 2484-2494 ◽  
Author(s):  
Juan José Rodríguez-Bencomo ◽  
Carolina Muñoz-González ◽  
Inmaculada Andújar-Ortiz ◽  
Pedro Jose Martín-Álvarez ◽  
Maria Victoria Moreno-Arribas ◽  
...  

Author(s):  
Huiju Wang

Ionic     liquid (IL), 1-dodecyl-3-methylimidazolium-3-hydroxy-2-naphthoate (C12mimHNC) was synthesized and coated on the surface of NiTi as solid phase microextractiom fiber coating for determination the octadecylamine in brine. Prior to modification with IL, the NiTi was hydrothermally treated for in-situ growth of titanium and nickel oxide composite nanosheets (TiO2/NiOCNSs). The TiO2/NiOCNSs fibers coating was oriented  around the NiTi  substrate and  presented  double-faced  open  access  sites,  which provided a desired support framework for the further modification with IL. The extraction performance of C12mimHNC-TiO2/NiOCNSs fiber coating was evaluated for       detection of octadecylamine (ODA) coupled to HPLC with UV detection. As a result, the C12mimHNC-TiO2/NiOCNSs fiber coating illustrated excellent adsorption and extraction capability for ODA. The main factors affected extraction efficiency were optimized. Under the optimized  conditions,  good  linearity was  obtained  in  the  range of  1-150  µg/L with correlation  coefficients  (r2)  above  0.985.  Limits of detection (LODs) for  the  developed method was 0.280 µg/L. The proposed method was first applied to extract the ODA in brine samples. Relative recoveries varied from 78.3% to 96.5% at spiking level of 15µg/L and 30 µg/L with the relative standard deviations (RSDs) less than 8.7%.


Sign in / Sign up

Export Citation Format

Share Document