P-62: Improvement in PDP Image Quality by Suppressing Dynamic False Contour While Maintaining High Brightness

2003 ◽  
Vol 34 (1) ◽  
pp. 455 ◽  
Author(s):  
Bei Lei Xu ◽  
Zheng Cai Xie ◽  
Jin Shou Tian ◽  
Han Ben Niu
Author(s):  
Akira Yonezawa ◽  
Seiichi Nakagawa ◽  
Mikio Suzuki

The LaB6 cathode gun, which is noted for its high brightness and long life, is highly expected to improve the image quality of CTEM,STEM and secondary electron images. But, in order that the LaB6 gun may stably attain its maximum performance, it is necessary to solve big prblems concerning the vacuum pressure around the tip and with tip holding and heating.Here, we shall introduce excellent data and CTEM and secondary electron images, obtained by a clean high vacuum EM, the JEM-100CX with aid of a LaB6 emitter assembly1)commercialized as an option for the JSM-35. The instrument also used a high resolution scanning device, ASID-4D to obtain the secondary electron images. The JEM-100CX can easily attain, even in the gun chamber, a 10-7 torr clean high vacuum which is high enough for a LaB6 tip, because it employs the “CASCADE” differential pumping system2). We shall discuss the gun assembly.


1998 ◽  
Vol 29 (1) ◽  
pp. 287 ◽  
Author(s):  
T. Shigeta ◽  
N. Saegusa ◽  
H. Honda ◽  
T. Nagakubo ◽  
T. Akiyama

Author(s):  
F. A. Heckman ◽  
E. Redman ◽  
J.E. Connolly

In our initial publication on this subject1) we reported results demonstrating that contrast is the most important factor in producing the high image quality required for reliable image analysis. We also listed the factors which enhance contrast in order of the experimentally determined magnitude of their effect. The two most powerful factors affecting image contrast attainable with sheet film are beam intensity and KV. At that time we had only qualitative evidence for the ranking of enhancing factors. Later we carried out the densitometric measurements which led to the results outlined below.Meaningful evaluations of the cause-effect relationships among the considerable number of variables in preparing EM negatives depend on doing things in a systematic way, varying only one parameter at a time. Unless otherwise noted, we adhered to the following procedure evolved during our comprehensive study:Philips EM-300; 30μ objective aperature; magnification 7000- 12000X, exposure time 1 second, anti-contamination device operating.


Author(s):  
K. Shibatomi ◽  
T. Yamanoto ◽  
H. Koike

In the observation of a thick specimen by means of a transmission electron microscope, the intensity of electrons passing through the objective lens aperture is greatly reduced. So that the image is almost invisible. In addition to this fact, it have been reported that a chromatic aberration causes the deterioration of the image contrast rather than that of the resolution. The scanning electron microscope is, however, capable of electrically amplifying the signal of the decreasing intensity, and also free from a chromatic aberration so that the deterioration of the image contrast due to the aberration can be prevented. The electrical improvement of the image quality can be carried out by using the fascionating features of the SEM, that is, the amplification of a weak in-put signal forming the image and the descriminating action of the heigh level signal of the background. This paper reports some of the experimental results about the thickness dependence of the observability and quality of the image in the case of the transmission SEM.


Author(s):  
W.R. Bottoms ◽  
G.B. Haydon

There is great interest in improving the brightness of electron sources and therefore the ability of electron optical instrumentation to probe the properties of materials. Extensive work by Dr. Crew and others has provided extremely high brightness sources for certain kinds of analytical problems but which pose serious difficulties in other problems. These sources cannot survive in conventional system vacuums. If one wishes to gather information from the other signal channels activated by electron beam bombardment it is necessary to provide sufficient current to allow an acceptable signal-to-noise ratio. It is possible through careful design to provide a high brightness field emission source which has the capability of providing high currents as well as high current densities to a specimen. In this paper we describe an electrode to provide long-lived stable current in field emission sources.The source geometry was based upon the results of extensive computer modeling. The design attempted to maximize the total current available at a specimen.


Author(s):  
N.J. Tighe ◽  
H.M. Flower ◽  
P.R. Swann

A differentially pumped environmental cell has been developed for use in the AEI EM7 million volt microscope. In the initial version the column of gas traversed by the beam was 5.5mm. This permited inclusion of a tilting hot stage in the cell for investigating high temperature gas-specimen reactions. In order to examine specimens in the wet state it was found that a pressure of approximately 400 torr of water saturated helium was needed around the specimen to prevent dehydration. Inelastic scattering by the water resulted in a sharp loss of image quality. Therefore a modified cell with an ‘airgap’ of only 1.5mm has been constructed. The shorter electron path through the gas permits examination of specimens at the necessary pressure of moist helium; the specimen can still be tilted about the side entry rod axis by ±7°C to obtain stereopairs.


Author(s):  
A. Strojnik ◽  
J.W. Scholl ◽  
V. Bevc

The electron accelerator, as inserted between the electron source (injector) and the imaging column of the HVEM, is usually a strong lens and should be optimized in order to ensure high brightness over a wide range of accelerating voltages and illuminating conditions. This is especially true in the case of the STEM where the brightness directly determines the highest resolution attainable. In the past, the optical behavior of accelerators was usually determined for a particular configuration. During the development of the accelerator for the Arizona 1 MEV STEM, systematic investigation was made of the major optical properties for a variety of electrode configurations, number of stages N, accelerating voltages, 1 and 10 MEV, and a range of injection voltages ϕ0 = 1, 3, 10, 30, 100, 300 kV).


Author(s):  
N. Tamura ◽  
T. Goto ◽  
Y. Harada

On account of its high brightness, the field emission electron source has the advantage that it provides the conventional electron microscope with highly coherent illuminating system and that it directly improves the, resolving power of the scanning electron microscope. The present authors have reported some results obtained with a 100 kV field emission electron microscope.It has been proven, furthermore, that the tungsten emitter as a temperature field emission source can be utilized with a sufficient stability under a modest vacuum of 10-8 ~ 10-9 Torr. The present paper is concerned with an extension of our study on the characteristics of the temperature field emitters.


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


Sign in / Sign up

Export Citation Format

Share Document