scholarly journals Computer simulation of temperature field of blast furnaces air tuyere

2017 ◽  
Vol 9 (1) ◽  
pp. 117-125 ◽  
Author(s):  
Alexander G. Radjuk ◽  
Alexander E. Titlianov ◽  
Mikhail M. Skripalenko
Open Physics ◽  
2018 ◽  
Vol 16 (1) ◽  
pp. 326-331
Author(s):  
Jerzy Zgraja

Abstract Predictive computer simulation of the temperature field control system of an induction heated object encounters difficulties associated with the nonlinearityof systemon the one hand, and the time of calculation on the other hand, during numerical analysis of the magnetothermal field of the object, especially in 3D. The paper presents a methodology for the fast simulation of temperature field for a completed induction heating system of calender rolls. The method of 3D calculations of rotating calender rolls with a moving web of wet paper can be connected easily with a simulation of the temperature field controller, for simulation of complex control systems.


2004 ◽  
Vol 30 (7) ◽  
pp. 1847-1850 ◽  
Author(s):  
Liang Li ◽  
Liangying Zhang ◽  
Xi Yao ◽  
Bo Li

2013 ◽  
Vol 43 (5) ◽  
pp. 231-235 ◽  
Author(s):  
N. L. Kirillova ◽  
A. G. Radyuk ◽  
A. E. Titlyanov ◽  
S. M. Gorbatyuk
Keyword(s):  

Metallurgist ◽  
2018 ◽  
Vol 62 (3-4) ◽  
pp. 310-313 ◽  
Author(s):  
A. G. Radyuk ◽  
A. E. Titlyanov ◽  
M. M. Skripalenko ◽  
S. S. Stoishich

Author(s):  
N. Tamura ◽  
T. Goto ◽  
Y. Harada

On account of its high brightness, the field emission electron source has the advantage that it provides the conventional electron microscope with highly coherent illuminating system and that it directly improves the, resolving power of the scanning electron microscope. The present authors have reported some results obtained with a 100 kV field emission electron microscope.It has been proven, furthermore, that the tungsten emitter as a temperature field emission source can be utilized with a sufficient stability under a modest vacuum of 10-8 ~ 10-9 Torr. The present paper is concerned with an extension of our study on the characteristics of the temperature field emitters.


Author(s):  
M.V. Parthasarathy ◽  
C. Daugherty

The versatility of Low Temperature Field Emission SEM (LTFESEM) for viewing frozen-hydrated biological specimens, and the high resolutions that can be obtained with such instruments have been well documented. Studies done with LTFESEM have been usually limited to the viewing of small organisms, organs, cells, and organelles, or viewing such specimens after fracturing them.We use a Hitachi 4500 FESEM equipped with a recently developed BAL-TEC SCE 020 cryopreparation/transfer device for our LTFESEM studies. The SCE 020 is similar in design to the older SCU 020 except that instead of having a dedicated stage, the SCE 020 has a detachable cold stage that mounts on to the FESEM stage when needed. Since the SCE 020 has a precisely controlled lock manipulator for transferring the specimen table from the cryopreparation chamber to the cold stage in the FESEM, and also has a motor driven microtome for precise control of specimen fracture, we have explored the feasibility of using the LTFESEM for multiple-fracture studies of the same sample.


Author(s):  
Kiyomichi Nakai ◽  
Yusuke Isobe ◽  
Chiken Kinoshita ◽  
Kazutoshi Shinohara

Induced spinodal decomposition under electron irradiation in a Ni-Au alloy has been investigated with respect to its basic mechanism and confirmed to be caused by the relaxation of coherent strain associated with modulated structure. Modulation of white-dots on structure images of modulated structure due to high-resolution electron microscopy is reduced with irradiation. In this paper the atom arrangement of the modulated structure is confirmed with computer simulation on the structure images, and the relaxation of the coherent strain is concluded to be due to the reduction of phase-modulation.Structure images of three-dimensional modulated structure along <100> were taken with the JEM-4000EX high-resolution electron microscope at the HVEM Laboratory, Kyushu University. The transmitted beam and four 200 reflections with their satellites from the modulated structure in an fee Ni-30.0at%Au alloy under illumination of 400keV electrons were used for the structure images under a condition of the spherical aberration constant of the objective lens, Cs = 1mm, the divergence of the beam, α = 3 × 10-4 rad, underfocus, Δf ≃ -50nm and specimen thickness, t ≃ 15nm. The CIHRTEM code was used for the simulation of the structure image.


Sign in / Sign up

Export Citation Format

Share Document