scholarly journals Experimental investigation on evaporation of R407C in a single horizontal smooth tube

Author(s):  
M. D. Hambarde ◽  
Ramakant Shrivastava ◽  
S.R. Thorat ◽  
O.P. Dale

Due to higher ozone layer depletion potential of HCFC refrigerant, R22 which has been mostly used in house hold refrigeration will be phased out by 2020 as per Montreal Protocol and UNFCCC Regulations. R407C, a zeotropic refrigerant from HFC category is a promising refrigerants in place of R22. Performance evaluation of R407 is required to enhance its application in house hold refrigeration. Hence an experimental investigation is carried out to understand the heat transfer characteristics during flow boiling of R407C in a smooth horizontal tube of 13.386 mm inner diameter and 2m length. The experiment is performed under the operating conditions; (i) mass flux range 100 to 300 kg s-1m-2; (ii) heat flux within range 2 to 7 kWm-2; (iii) temperature range at inlet to test section -100C to +100C; (iv) average vapor quality within test section from 0.05 to 0.95.The effect of heat flux, mass flux, vapor quality, temperature glide on heat transfer coefficient, during evaporation of R407C are examined.

Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5972
Author(s):  
Yu Xu ◽  
Zihao Yan ◽  
Ling Li

To protect the environment, a new low-GWP refrigerant R1234ze(E) was created to substitute R134a. However, its flow boiling performances have not received sufficient attention so far, which hinders its popularization to some extent. In view of this, an experimental investigation was carried out in a 1.88 mm horizontal circular minichannel. The saturation pressures were maintained at 0.6 and 0.7 MPa, accompanied by mass flux within 540–870 kg/m2 s and heat flux within 25–65 kW/m2. For nucleate boiling, a larger heat flux brings about a larger heat transfer coefficient (HTC), while for convective boiling, the mass flux and vapor quality appear to take the lead role. The threshold vapor quality of different heat transfer mechanisms is around 0.4. Additionally, larger saturation pressure results in large HTC. As for the frictional pressure drop (FPD), it is positively influenced by mass flux and vapor quality, while negatively affected by saturation pressure, and the influence of heat flux is negligible. Furthermore, with the measured data, several existing correlations are compared. The results indicate that the correlations of Saitoh et al. (2007) and Müller-Steinhagen and Heck (1986) perform best on flow boiling HTC and FPD with mean absolute deviations of 5.4% and 10.9%.


Author(s):  
K. S. Park ◽  
W. H. Choo ◽  
K. H. Bang

The flow boiling heat transfer coefficient of R-22 in small hydraulic diameter tubes has been experimentally studied. Both brass and aluminum round tubes of 1.66 mm inside diameter are used for the test section. The ranges of the major experimental parameters are 300∼600 kg/m2s of refrigerant mass flux, 10∼20 kW/m2 of the wall heat flux, 0.0∼0.9 of the inlet vapor quality. The experimental result showed that the flow boiling heat transfer coefficient in this small tubes are in the range of 2∼4 kW/m2K and it varies only by heat flux, independent of mass flux and vapor quality. It is also observed that the heat transfer coefficients in the aluminum tube are up to 50% higher than in the brass tube.


Author(s):  
K. H. Bang ◽  
W. H. Choo

The past work on flow boiling heat transfer in minichannels ranging one to three millimeters of hydraulic diameter has indicated that the local heat transfer coefficients are largely independent of mass flux and vapor quality, but mainly a function of wall heat flux. The present work is a revisit of flow boiling in minichannels by conducting experiment using 1.67 mm inner diameter tubes of three different materials; aluminum, brass, and copper, to investigate an effect of the tube inner surface conditions with the focus on an effect on nucleate boiling. Tests were conducted for R-22, a fixed mass flux of 600 kg/m2s, 5∼30 kW/m2 of wall heat flux, 0.0∼0.9 of local vapor quality. The present experimental data confirmed that the flow boiling heat transfer coefficient in a minichannel varies only by heat flux, independent of mass flux and vapor quality. The effect of tube material was found small for the tubes used in the present work. The present data were well predicted by the correlation proposed by Tran et al. (1996).


2000 ◽  
Author(s):  
Yuan Zhao ◽  
Majid Molki ◽  
Michael M. Ohadi

Abstract An experimental investigation was performed to study the flow boiling heat transfer of CO2 in microchannels. Tests were conducted in a horizontal triangular microchannel with the hydraulic diameter of 0.86 mm. Heat to the test section was provided by direct electrical heating. Experiments were conducted with CO2 at saturation temperatures of 273 to 293 K, mass fluxes of 100 to 820 kg/m2s, heat fluxes of 3 to 23 kW/m2, and qualities of 20% to 85%. It was demonstrated that heat flux had an enhancing effect on the heat transfer coefficient, while mass flux had a negligible effect. Nucleate boiling mechanism is found to be the dominant factor for CO2 flow boiling in microchannels. Heat transfer coefficient degraded quickly at high vapor quality region (0.6–0.7), which is possibly due to flow mal-distribution. Pressure drop increases slightly with vapor quality and/or heat flux. Mass flux has a strong increasing effect on pressure drop.


Author(s):  
Saptarshi Basu ◽  
Sidy Ndao ◽  
Gregory J. Michna ◽  
Yoav Peles ◽  
Michael K. Jensen

An experimental study of two-phase heat transfer coefficients was carried out using R134a in uniformly heated horizontal circular microtubes with diameters of 0.50 mm and 1.60 mm. The effects of mass flux, heat flux, saturation pressure, and vapor quality on heat transfer coefficients were studied. The flow parameters investigated were as follows: exit pressures of 490, 670, 890, and 1160 kPa; mass fluxes of 300–1500 kg/m2s; heat fluxes of 0–350 kW/m2; inlet subcooling of 5, 20, and 40 °C; and exit qualities of 0 to 1.0. The parametric trends presented in the study are consistent with published literature. Heat transfer coefficients increased with increasing heat flux and saturation pressure while they were independent of variations in mass flux. Vapor quality had a negligible influence on heat transfer coefficients. For the conditions studied, the trends indicated that the dominant heat transfer mechanism was nucleate boiling. The experimental data was compared to three microchannel correlations — the Lazarek-Black, the Kandlikar, and the Tran Correlations. None of the correlations predicted the experimental data very well, although they all predicted the correct trend within limits of experimental error.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4617
Author(s):  
Sanghyun Nam ◽  
Dae Yeon Kim ◽  
Youngwoo Kim ◽  
Kyung Chun Kim

Heat transfer under flow boiling is better in a rectangular channel filled with open-cell metal foam than in an empty channel, but the high pressure drop is a drawback of the empty channel method. In this study, various types of metal foam insert configurations were tested to reduce the pressure drop while maintaining high heat transfer. Specifically, we measured the boiling heat transfer and pressure drop of a two-phase vertical upward flow of R245fa inside a channel. To measure the pressure and temperature differences of the metal foam, differential pressure transducers and T-type thermocouples were used at both ends of the test section. While the saturation pressure was kept constant at 5.9 bar, the steam quality at the inlet of the test section was changed from 0.05 to 0.99. The channel height, moreover, was 3 mm, and the mass flux ranged from 133 to 300 kg/m2s. The two-phase flow characteristics were observed through a high-speed visualization experiment. Heat transfer tended to increase with the mean vapor quality, and, as expected, the fully filled metal foam channel offered the highest thermal performance. The streamwise insert pattern model had the lowest heat transfer at a low mass flux. However, at a higher mass flux, the three different insert models presented almost the same heat transfer coefficients. We found that the streamwise pattern model had a very low pressure drop compared to that of the spanwise pattern models. The goodness factors of the flow area and the core volume of the streamwise patterned model were higher than those of the full-filled metal foam channel.


Author(s):  
Hailei Wang ◽  
Richard Peterson

Flow boiling and heat transfer enhancement in four parallel microchannels using a dielectric working fluid, HFE 7000, was investigated. Each channel was 1000 μm wide and 510 μm high. A unique channel surface enhancement technique via diffusion bonding a layer of conductive fine wire mesh onto the heating wall was developed. According to the obtained flow boiling curves for both the bare and mesh channels, the amount of wall superheat was significantly reduced for the mesh channel at all stream-wise locations. This indicated that the nucleate boiling in the mesh channel was enhanced due to the increase of nucleation sites the mesh introduced. Both the nucleate boiling dominated and convective evaporation dominated regimes were identified. In addition, the overall trend for the flow boiling heat transfer coefficient, with respect to vapor quality, was increasing until the vapor quality reached approximately 0.4. The critical heat flux (CHF) for the mesh channel was also significantly higher than that of the bare channel in the low vapor quality region. Due to the fact of how the mesh was incorporated into the channels, no pressure drop penalty was identified for the mesh channels. Potential applications for this kind of mesh channel include high heat-flux electronic cooling systems and various energy conversion systems.


Author(s):  
Kwang-Hyun Bang ◽  
Kun-Eui Hong ◽  
In-Seon Hwang

This paper reports an experimental study on flow boiling of water in a minichannel. Flow boiling heat transfer coefficients and pressure drops were measured and the data were compared with existing correlations. The effect of pressure was the major objectives in this study and the range of pressure was 1 to 18 bars. The experimental apparatus consisted mainly of a minichannel test section, gear pump, pre-heater, pressurizer, condenser and evaporator. The evaporator was used for variation of vapor quality at the inlet of test section. The pressurizer controls the desired system pressure. The test section is a round tube of 1.73 mm inside diameter, made of 316 stainless steel. The test section and the evaporator tubes were heated by DC electric current through the tubes. The measured flow boiling heat transfer coefficients showed two distinct regions; relatively high heat transfer coefficients at low vapor quality and lower heat transfer coefficients at higher vapor quality. This observation implies the change of flow regime, slug to annular flow. Comparisons of the experimental data and the prediction of correlations (Gungor & Winterton, 1987; Tran et al., 1996; Kandlikar, 2003) showed large discrepancy in both regions.