Traffic Noise Characteristic of High-rise Apartment Complex Nearby Highway

Author(s):  
Chang-Geun Cho ◽  
Jong-Soo Park
2003 ◽  
Vol 34 (8) ◽  
pp. 8-17
Author(s):  
Jiping Zhang

A method for theoretically calculating the coherence between sound pressure inside a rectangular room in a high-rise building and that outside the open window of the room is proposed. The traffic noise transmitted into a room is generally dominated by low-frequency components, to which active noise control (ANC) technology may find an application. However, good coherence between reference and error signals is essential for effective noise reduction and should be checked first. Based on traffic noise prediction methods, wave theory, and mode coupling theory, the results of this paper enable one to determine the potentials and limitations of ANC used to reduce such a transmission. Experimental coherence results are shown for two similar, empty rectangular rooms located on the 17th and 30th floors of a 34 floor high-rise building. The calculated results with the proposed method are generally in good agreement with the experimental results and demonstrate the usefulness of the method for predicting the coherence.


2022 ◽  
Vol 355 ◽  
pp. 02061
Author(s):  
Jiang Li ◽  
YongBin Li ◽  
Jinhua Tan ◽  
Zhimin Yang

Fully enclosed noise barrier has been used to prevent and control traffic noise pollution because of its effectiveness. It has become the best solution for controlling environmental noise of high-rise buildings from expressways, urban viaducts and railways that cross the crowded downtown area. However, its high cost has become an important retarding factor on its application and popularization, so reducing the cost become an urgent problem. The research theory, structure frame, sound absorbing and insulating materials are investigated for the fully enclosed noise barrier, so as to provide technical solutions for optimizing the design scheme and reducing the construction cost.


1976 ◽  
Vol 47 (4) ◽  
pp. 599-601 ◽  
Author(s):  
N.W.M. Ko
Keyword(s):  

2021 ◽  
Vol 263 (4) ◽  
pp. 2875-2886
Author(s):  
Jiping Zhang ◽  
Zheming Wang ◽  
Heng Ma ◽  
Weike Wang

The facade insulation (FI) is one choice for Road traffic noise (RTN) at a high-rise accommodation building nearby a motor road. The weakness of FI is from window, so the window insulation (WI) is also a prioritized descriptor. ISO16283-3 states a field method to measure FI using RTN. However, in room acoustics, besides FI, reverberation time (RBT) or indoor average sound absorption (IASB) are another two un-ignorable descriptors. When the value of IASB is small, the indoor noise is not only contributed from penetrating façade RTN, but also supplemented by the residual sound from high reverberation field, weakening FI. As a parallel to ISO16283-3, this paper suggests an engineering method to measure RBT and IASB of one high-rise building room close to a motor road by penetrating façade RTN. It can supply a convenient tool for the field measurement of RBT and IASB with RTN. At the end, we made a field measurement of RBT, IASB, and WI at a hotel room nearby a viaduct in Hangzhou of China, assistant to adjust RBT or IASB and WI so as to improve the sound quality of the hotel. Further, the method can extend to the lines of rail, aviation, and shipping.