scholarly journals Methodology of Defining of the Radiation Therapy Components for Various Methods of Patients’ Treating Using Medical Linear Accelerators and Gamma-Therapeutic Devices

2020 ◽  
Vol 11 (4) ◽  
pp. 289-297
Author(s):  
E. V. Titovich ◽  
M. N. Piatkevich ◽  
N. I. Makarava

One of the main factors affecting the effectiveness of radiation therapy is the constancy of the patient’s position on the treatment table created by immobilization devices of various designs and held throughout the entire irradiation procedure, which guarantees the accuracy of the delivery of the prescribed dose distribution. The purpose of the work was to establish the numerical values of the dominant components of a radiation therapy session for each of the irradiation techniques most commonly used in clinical practice of the radiation therapy.To determine the numerical values of the components of the radiation therapy session, the authors have measured each component for some clinical cases of patients’ irradiation placed. The patients had been diagnosed with the following malignant tumours: prostate cancer, breast cancer, lung cancer, head and neck tumours. More than 2000 individual measurements have been carried out with the help of such medical linear accelerators as "Clinac", "Unique", "Truebeam", and the gamma-therapeutic apparatus named "Theratron".The numerical values of the time spent on 3 groups of parameters of an irradiation session were established: the mechanical parameters of the radiation therapy equipment, the functional characteristics of the irradiation systems and the parameters that directly depend on the personnel involved in an irradiation procedure.According to the measurement results, the flow diagram for the procedures of verifying a patient’s position on the therapeutic table (2 different techniques), preceding their irradiation and the radiation therapy procedures themselves was proposed. It has been shown that a number of session components can run in parallel to each other thus optimizing the time spent by a patient in the treatment room.Using the obtained values of the time spent on the radiation session parameters it is possible to actualize the mathematical model that will allow the medical physicist to determine in advance the duration of the irradiation session at the stage of treatment planning and choose a radiation therapy technique taking into account the individual parameters of the irradiation session in each particular clinical case.

2020 ◽  
Vol 15 (1) ◽  
Author(s):  
Younes Afkham ◽  
Asghar Mesbahi ◽  
Abdolali Alemi ◽  
Farhad Zolfagharpour ◽  
Nasrollah Jabbari

2012 ◽  
Vol 27 (4) ◽  
pp. 368-373 ◽  
Author(s):  
Wazir Muhammad ◽  
Lee Hoon ◽  
Khan Alam ◽  
Muhammad Maqbool ◽  
Gulzar Khan

The purpose of this work is to study dose non-linearity in medical linear accelerators used in conventional radiotherapy and intensity-modulated radiation therapy. Open fields, as well as the enhanced dynamic wedge ones, were used to collect data for 6 MV and 15 MV photon beams obtained from the VARIAN linear accelerator. Beam stability was checked and confirmed for different dose rates, energies, and application of enhanced dynamic wedge by calculating the charge per monitor unit. Monitor unit error was calculated by the two-exposure method for open and enhanced dynamic wedge beams of 6 MV and 15 MV photons. A significant monitor unit error with maximum values of ?2.05931 monitor unit and ?2.44787 monitor unit for open and enhanced dynamic wedge beams, respectively, both energy and dose rate dependent, was observed both in the open photon beam and enhanced dynamic wedge fields. However, it exhibited certain irregular patterns at enhanced dynamic wedge angles. Dose monitor unit error exists only because of the overshoot phenomena and electronic delay in dose coincident and integrated circuits with a dependency on the dose rate and photon energy. Monitor unit errors are independent of the application of enhanced dynamic wedge. The existence of monitor unit error demands that the dose non-linearity of the linear accelerator dosimetry system be periodically tested, so as to avoid significant dosimetric errors.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Siji Cyriac ◽  
M. M. Musthafa ◽  
R. Ganapathi Raman ◽  
K. Abdul Haneefa ◽  
V. T. Hridya

Pretreatment quality assurance (QA) is a major concern in complex radiation therapy treatment plans like intensity modulated radiation therapy (IMRT). Present study considers the variations in gamma index for gantry dependent pretreatment verification and commonly practiced zero gantry angle verifications for ten prostate IMRT plans using two commercial medical linear accelerators (Varian 2300 CD, Varian Clinac iX). Two verification plans (the one with all fields at the actual treatment angles and one with all fields merged to 0 degree gantry angles) for all the patients were generated to obtain dose fluence mapping using amorphous silicon electronic portal imaging device (EPID). The gamma index was found depend on gantry angles but the difference between zero and the nonzero treatment angles is in the confidence level for clinical acceptance. The acceptance criteria of gamma method were always satisfied in both cases for two machines and are stable enough to execute the patient specific pretreatment quality assurance at 0 degree gantry angle for prostate IMRTs, where limited number of gantry angles are used.