scholarly journals High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples

2013 ◽  
Vol 10 (3) ◽  
pp. 1014-1022
Author(s):  
Baghdad Science Journal

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.

INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


2008 ◽  
Vol 91 (5) ◽  
pp. 1025-1036 ◽  
Author(s):  
Mohammed Shahid Ali ◽  
Syed Rafiuddin ◽  
Muhammad Imran Munir ◽  
Mohsin Ghori ◽  
Aamer Roshanali Khatri

Abstract A reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of benzoyl peroxide and the related compounds benzoic acid (BA), methylparaben, benzaldehyde, propylparaben, and ethyl benzoate. The compounds are separated on a column containing octadecyl silane chemically bonded to porous silica particles. The mobile phase is acetonitrilebuffer (45 + 55, v/v). Solutions are injected into the chromatographic system under isocratic conditions at a constant flow rate of 1.5 mL/min with UV detection at 235 nm. Analysis of stability samples showed rapid accumulation of BA by thermal degradation. A rationale has been established for the acceptable limit of BA in the formulation, which already contains BA (0.2) as a preservative. The proposed method is efficient and determines the active compound and 5 related compounds in a run time of 20 min. The method was validated according to the guidelines of the International Conference on Harmonization and demonstrated good agreement with the validation requirements.


Sign in / Sign up

Export Citation Format

Share Document