scholarly journals Determination of trace amounts of boron in high purity graphite by ICP-MS.

1994 ◽  
Vol 43 (6) ◽  
pp. 495-498 ◽  
Author(s):  
Toshiyuki MIYATANI ◽  
Hitoshi SUZUKI ◽  
Osamu YOSIMOTO
Keyword(s):  
2019 ◽  
Vol 40 (5) ◽  
pp. 167-172 ◽  
Author(s):  
Yan Zhang ◽  
Zhongben Pan ◽  
Pengchong Jiao ◽  
Jia Ju ◽  
Ting He ◽  
...  

2003 ◽  
Vol 89 (9) ◽  
pp. 958-961 ◽  
Author(s):  
Shin-ichi HASEGAWA ◽  
Kunikazu IDE ◽  
Takeshi KOBAYASHI ◽  
Koichi SATO ◽  
Shukuro IGARASHI ◽  
...  

Metals ◽  
2018 ◽  
Vol 8 (10) ◽  
pp. 851 ◽  
Author(s):  
Manh Chu ◽  
Lan Nguyen ◽  
Xuan Mai ◽  
Doan Thuan ◽  
Long Bach ◽  
...  

High purity Zirconium (Zr) materials are essential in many components of nuclear reactors, especially fuel cladding tubes. Due to the matrix influence, determination of impurities in the Zr materials requires separation from the Zr matrix. Among extraction methods, solvent extraction is common and suitable for large-scale production. In this study, extraction capability of Zr(IV) by 2-ethylhexyl phosphonic acid mono 2-ethylhexyl ester (PC88A) was examined by FT-IR and UV of ZrO(NO3)2 salt, PC88A-toluene solvent, and Zr-PC88A-toluene complex. ZrO2 (obtained from Institute for Technology of Radioactive and Rare Elements—ITRRE), after being separated from the Zr matrix, was determined for impurities using internal standard (indium, In) by 50% of PC88A dissolved in toluene. Separation of impurities from the Zr matrix underwent two stages. First, one cycle of extraction of the Zr matrix and impurities in 3 M HNO3 using 50% PC88A/toluene was conducted. Second, impurities were scrubbed by 4 M HNO3 in two cycles. Results revealed that approximately 74% of Zr(IV) was separated to the organic phase and 26% remained in the aqueous phase. Determination of impurities after separation from the Zr matrix by ICP-MS using internal standard in revealed that the recovery of impurities achieved 95–100%. With the mentioned amount of Zr, the effect of the Zr matrix on the determination of elements by ICP-MS is negligible. Levels of impurities have relative standard deviations (RSD) of less than 6.9% and recovery of 88.6–98.8%. Therefore, the determination of impurities has high reliability and accuracy. The back-extraction of Zr(IV) in organic phase by 1 M H2SO4 has stripped about 99.5% of the Zr matrix back to the aqueous phase. Following this, NH3 was added to the solution containing Zr after back-extraction to form Zr(OH)4 which was then desiccated to produce ZrO2. X-ray Diffraction (XRD), Scanning and Transmission Electron Microscopy (SEM and TEM) images showed that the new ZrO2 product has spherical nanostructure with diameters of less than 25 nm, which is suitable for applications for the treatment of colorants, metal ions in wastewater sources and manufacture of anti-corrosion steel. In addition, the energy dispersive X-ray (EDX) of the new ZrO2 product showed that it has high purity.


2015 ◽  
Vol 815 ◽  
pp. 76-79
Author(s):  
Yi Ni Shi ◽  
Kai Pei ◽  
Yin Feng Zhao ◽  
Yun Tan ◽  
Zhen Tai ◽  
...  

A method for detecting impurities in high purity BCl3 was described in the present work. GC, ICP-MS, FTIR and colorimetric method were applied to analyze high-purity BCl3. The quantitative results of the impurities such as N2, CO, CO2 and Fe demonstrated that these methods had excellent repeatability (RSD<3%), reproducibility. The ICP-MS detection accuracy can achieve ppb limiter. The FTIR method provided opportunities for the determination of HCl, COCl2, which have difficulties in quantification with other method.


Sign in / Sign up

Export Citation Format

Share Document