Repeatability of ocular surface vessel density measurements with optical coherence tomography angiography

2018 ◽  
2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Sijie Cai ◽  
Fengping Zhao ◽  
Chixin Du

Abstract Background To determine the repeatability of measurements of ocular surface vessel density in normal and diseased eyes using optical coherence tomography angiography (OCTA). Methods Ten normal eyes, 10 pinguecula eyes, and 10 pterygium eyes of 30 volunteers were subjected to OCTA (AngioVue Imaging System, Optovue, Inc.). For scanning, we used the corneal adapter module. Each eye was scanned three times in the nasal and temporal directions, separately. AngioVue software was used to generate the ocular surface vessel density. Ocular surface vessel density was defined as the proportion of vessel area with blood flow to the total measurement area (3 × 3 mm2). Intersession repeatability of the measurement was summarized as the coefficient of variation (CV), and intraclass correlation coefficients (ICC) were calculated by variance component models. Results The CVs were less than 5% in all subjects, and the ICCs exceeded 0.9; thus, all measurements showed good repeatability. The nasal vessels densities differed significantly between healthy eyes and eyes with pterygium (P < 0.05); however, there was no significant difference between healthy eyes and eyes with pinguecula (P = 0.466). Conclusions These results suggest that measurement of ocular surface vessel density by OCTA in normal eyes and eyes with pterygium and pinguecula is repeatable. This preliminary research describes a quantitative and visual method for assessing vessel density of the ocular surface with a high level of consistency.


2020 ◽  
Vol 12 ◽  
pp. 251584142094793
Author(s):  
Khalil Ghasemi Falavarjani ◽  
Reza Mirshahi ◽  
Shahriar Ghasemizadeh ◽  
Mahsa Sardarinia

Aim: To determine the minimum number of optical coherence tomography B-scan corrections required to provide acceptable vessel density measurements on optical coherence tomography angiography images in eyes with diabetic macular edema. Methods: In this prospective, noninterventional case series, the optical coherence tomography angiography images of eyes with center-involving diabetic macular edema were assessed. Optical coherence tomography angiography imaging was performed using RTVue Avanti spectral-domain optical coherence tomography system with the AngioVue software (V.2017.1.0.151; Optovue, Fremont, CA, USA). Segmentation error was recorded and manually corrected in the inner retinal layers in the central foveal, 100th and 200th optical coherence tomography B-scans. The segmentation error correction was then continued until all optical coherence tomography B-scans in whole en face image were corrected. At each step, the manual correction of each optical coherence tomography B-scan was propagated to whole image. The vessel density and retinal thickness were recorded at baseline and after each optical coherence tomography B-scan correction. Results: A total of 36 eyes of 26 patients were included. To achieve full segmentation error correction in whole en face image, an average of 1.72 ± 1.81 and 5.57 ± 3.87 B-scans was corrected in inner plexiform layer and outer plexiform layer, respectively. The change in the vessel density measurements after complete segmentation error correction was statistically significant after inner plexiform layer correction. However, no statistically significant change in vessel density was found after manual correction of the outer plexiform layer. The vessel density measurements were statistically significantly different after single central foveal B-scan correction of inner plexiform layer compared with the baseline measurements ( p = 0.03); however, it remained unchanged after further segmentation corrections of inner plexiform layer. Conclusion: Multiple optical coherence tomography B-scans should be manually corrected to address segmentation error in whole images of en face optical coherence tomography angiography in eyes with diabetic macular edema. Correction of central foveal B-scan provides the most significant change in vessel density measurements in eyes with diabetic macular edema.


2017 ◽  
Vol 102 (3) ◽  
pp. 352-357 ◽  
Author(s):  
Jayasree P Venugopal ◽  
Harsha L Rao ◽  
Robert N Weinreb ◽  
Zia S Pradhan ◽  
Srilakshmi Dasari ◽  
...  

AimsTo compare the intrasession repeatability of peripapillary and macular vessel density measurements of optical coherence tomography angiography (OCTA) in normal and glaucoma eyes, and to evaluate the effect of signal strength of OCTA scans on the repeatability.MethodsIn a cross-sectional study, three optic nerve head scans each of 65 eyes (30 normal, 35 glaucoma eyes) and three macular scans each of 69 eyes (35 normal, 34 glaucoma eyes) acquired in the same session with OCTA were analysed. Repeatability was assessed using within-subject coefficient of repeatability (CRw) and variation (CVw). Effect of signal strength index (SSI) on repeatability was evaluated with repeated-measures mixed-effects models.ResultsCRw (%) and CVw (%) of peripapillary measurements in normal eyes ranged between 3.3 and 7.0, and 2.5 and 4.4 respectively, and that in glaucoma eyes between 3.5 and 7.1, and 2.6 and 6.6. For the macular, these measurements ranged between 4.1 and 6.0, and 3.3 and 4.7 in normal eyes and 4.3 and 6.9, and 3.7 and 5.6 in glaucoma eyes. Repeatability estimates of most measurements were similar in normal and glaucoma eyes. Vessel densities of both peripapillary and macular regions significantly increased with increase in SSI of repeat scans (coefficients ranging from 0.15 to 0.38, p<0.01 for all associations).ConclusionsRepeatability estimates of OCTA measured peripapillary and macular vessel densities were similar in normal eyes and eyes with glaucoma. SSI values of the scans had a significant effect on the repeatability of OCTA with the vessel density values increasing in scans with higher SSI values.


2020 ◽  
pp. bjophthalmol-2020-316930
Author(s):  
Marcus Ang ◽  
Kavya Devarajan ◽  
Anna CS Tan ◽  
Mengyuan Ke ◽  
Bingyao Tan ◽  
...  

PurposeTo compare anterior segment optical coherence tomography angiography (AS-OCTA) systems in delineating normal iris vessels and iris neovascularisation (NVI) in eyes with pigmented irides.MethodsProspective study from January 2019 to June 2019 of 10 consecutive patients with normal pigmented iris, had AS-OCTA scans with a described illumination technique, before using the same protocol in five eyes with NVI (clinical stages 1–3). All scans were sequentially performed using a spectral-domain OCTA (SD-OCTA), and a swept-source OCTA (SS-OCTA, Plex Elite 9000). Images were graded by two masked observers for visibility, artefacts and NVI characteristics. The main outcome measure was iris vessel density measurements comparing SS-OCTA and SD-OCTA systems.ResultsThe median age of subjects was 28 (20–35) years, and 50% were female. The paired mean difference of iris vessel density measurements was 11.7 (95% CI 14.7 to 8.1; p=0.002), SS-OCTA detecting more vessels than SD-OCTA. The inter-rater reliability for artefact score (κ=0.799, p<0.001) and visibility score (κ=0.722; p<0.001) were substantial. Both AS-OCTA systems were able to detect NVI vessels with a fair agreement (κ=0.588), with clearer NVI characteristics in stage 1/2 compared to stage 3 NVI (mean difference NVI score: 2.7±0.4, p=0.009).ConclusionThe SS-OCTA was better able to delineate iris vessels in normal pigmented irides compared to SD-OCTA. Both AS-OCTA systems identified NVI characteristics based on its atypical configuration or location, but further improvements are needed to allow for more accurate objective, serial quantification for clinical use.