scholarly journals Management of a Pipkin Type III Femoral Head Fracture Via Ganz Approach with a Cannulated Lag Screw & Herbert Screw

Author(s):  
Liangcong Hu ◽  
Xudong Xie ◽  
Bobin Mi ◽  
Le Grange Jehane Michael. ◽  
Tiantian Wang ◽  
...  

Abstract Objective: To evaluate the medium - to long-term efficacy of a Ganz approach and cannulated lag screw combined with Herbert screw, in the management of a Pipkin type III femoral head fracture.Methods:Retrospective analysis was performed on 11 patients (6 males, 5 females) who sustained Pipkin type III femoral head fractures and were managed with a cannulated lag screw, combined with Herbert screw, inserted using the Ganz approach and who were admitted to our department between June 2018 to June 2020. Perioperative indicators, postoperative function and follow-up complications at 9 months after surgery, Harris score at 6 and 9 months after surgery, Thompson-Epstein score, hip femoral head necrosis and incidence of post traumatic hip arthritis were analysis.Results:10 patients completed follow-up, with an average follow-up time of (13.7 ± 2.1) months. The mean operative time was (100.3 ± 23.67) minutes, intraoperative blood loss was (138.6 ± 50.18) ml, peripheral blood hemoglobin (Hb) was (105.6 ± 18.94) g/L 24 hours after surgery, and the complication rate was 1/10 2 weeks after surgery. The Harris Hip Scores for joint function at 6 and 9 months after the operation were (68.6 ± 5.49) points and (88.8 ± 5.77) points respectively. The excellent and good rate in the last follow-up was 80% (Thompson-Epstein score). The complication rate was 10%.Conclusion:A cannulated lag screw combined with a Herbert screw and inserted via the Ganz approach, is an effective method for the treatment of Pipkin type III fractures.

2017 ◽  
Vol 25 (1) ◽  
pp. 230949901668497 ◽  
Author(s):  
Yi-Hsun Yu ◽  
Yung-Heng Hsu ◽  
Ying-Chao Chou ◽  
I-Chuan Tseng ◽  
Chun-Yi Su ◽  
...  

Purpose: Pipkin type IV femoral head (FH) fracture was thought as poor prognosis. There were several surgical approaches and treatments for this difficult fracture. However, there was no one treatment superior to another. We reviewed a serious of patients with Pipkin type IV FH fracture underwent surgery via a modified Gibson approach. Methods: We reviewed a consecutive series of nine patients with Pipkin type IV FH fracture under surgery via a modified Gibson approach between 2012 and 2013. The surgical procedure was completely described, and the radiological outcome and the functional outcome were also reviewed. Results: The mean follow-up duration was 17 (12–30) months. The mean Merle d’Aubigne score was 16 (8–19). Seven patients had anatomical reductions, and two had imperfect reductions by Matta’s grading. There was no early posttraumatic osteoarthritis during the follow-up period. One patient with early post-traumatic osteonecrosis 3 months after index surgery underwent total hip arthroplasty. Conclusions: Through this surgery approach to fix the FH and the acetabulum, the radiological and the functional results were satisfactory. We still need more patients with prospective study to find an optimal surgical approach for Pipkin type IV FH fracture.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Alessandro Casiraghi ◽  
Claudio Galante ◽  
Marco Domenicucci ◽  
Stefano Cattaneo ◽  
Andrea Achille Spreafico ◽  
...  

AbstractThe aim of the present study was to present clinical and radiological outcome of a hip fracture-dislocation of the femoral head treated with biomimetic osteochondral scaffold.An 18-year-old male was admitted to the hospital after a motorcycle-accident. He presented with an obturator hip dislocation with a type IVA femoral head fracture according to Brumback classification system. The patient underwent surgery 5 days after accident. The largest osteochondral fragment was reduced and stabilized with 2 screws, and the small fragments were removed. The residual osteochondral area was replaced by a biomimetic nanostructured osteochondral scaffold. At 1-year follow-up the patient did not complain of hip pain and could walk without limp. At 2-year follow-up he was able to run with no pain and he returned to practice sports. Repeated radiographs and magnetic resonance imaging studies of the hip showed no signs of osteoarthritis or evidence of avascular necrosis. A hyaline-like signal on the surface of the scaffold was observed with restoration of the articular surface and progressive decrease of the subchondral edema.The results of the present study showed that the biomimetic nanostructured osteochondral scaffold could be a promising and safe option for the treatment of traumatic osteochondral lesions of the femoral head.Study Design: Case report.


Author(s):  
Jinwu Wang ◽  
Leyi Cai ◽  
Linzhen Xie ◽  
Hua Chen ◽  
Xiaoshan Guo ◽  
...  

Abstract Background Femoral head fractures are uncommon injuries. Open reduction and internal fixation (ORIF) of femoral head fracture is the preferred treatment for most patients. There are several surgical approaches and treatments for this difficult fracture. However, the optimal surgical approach for the treatment of femoral head fracture remains controversial. Meanwhile, the operation is difficult and the complications are numerous. We prospectively reviewed patients with femoral head fractures managed surgically through the 3D printing-based Ganz approach to define a better approach with the least morbidity. Patients and methods Between 2012 and 2017, a total of 17 patients were included in this study. An exact 1:1 3D printing model of the injured hip side was fabricated for each patient and simulated surgery was finished preoperative. The surgical approach was performed as described by Ganz. Functional assessment was performed using the modified Merle d’Aubigne scores. The reduction of the fracture was evaluated according to Matta’s criteria. The incidence of complications, such as heterotopic ossification (HO) and avascular necrosis (AVN), and the need for additional surgery were also documented. Results Twelve of 17 patients (four females and eight males) were available for 2 years follow-up. The mean follow-up was 35 months (25–48 months). Average age for the 12 patients was 39.9 ± 12.2 years. According to the Pipkin classification, four patients were type I fracture, three patients were type II fracture, and five patients were type IV fracture. The mean operative time was 124.2 ± 22.1 min, and the estimated blood loss was 437.5 ± 113.1 ml. According to Merle d’ Aubigne scores, excellent results were achieved in six of the 12 patients; four good and two poor results occurred in the rest of the patients. On the radiograph evaluation, fracture reduction was defined as anatomical in eight patients, and imperfect in four. Most patients had good outcomes and satisfactory hip function at last follow-up. Almost all great trochanteric osteectomy healed uneventfully. One patient developed symptomatic AVN of the femoral head and underwent THA at 3 years. After THA, she regained a good hip function with the ability to return to work and almost no reduction in sports activities. Heterotopic ossification was found in four cases (type I-1, type II-2, and type III-1). Conclusions The 3D printing-based Ganz approach provides a safe and reliable approach and satisfactory results of treatment in femoral head fractures. Using 3D printed model for the fracture of the femoral head, the fracture can be viewed in every direction to provide an accurate description of fracture characteristics, which contributes to make a reasonable surgical plan for patients. In addition, the 3D printing-based Ganz approach can obtain excellent surgical exposure and protection of the femoral head blood supply, reduce the operation time and intraoperative blood loss, make the precise osteotomy, anatomically fix the intra-articular fragments, and effectively reduce postoperative complications. Trial registration We register our research at http://www.researchregistry.com. The Unique Identifying Number (UIN) from the Research Registry of the study is researchregistry4847.


2021 ◽  
Author(s):  
Xinmin Yang ◽  
Ye Tian ◽  
Yao Yao

Abstract Background: To investigate the treatment effect of minimally invasive treatment of early osteonecrosis of femoral head (ONFH) with hydroxyapatite coated hollow titanium rod. Methods: From 1, January 2003 to 1, January 2019, 72 patients with ONFHⅡ Stage were selected. There were 50 males and 20 females, aged from 28 to 56. Onset time was 8~28 months. Lesion site: 18 left, 38 right, 16 bilateral. Causes of ONFH: 30 alcohol, 28 hormone, 9 trauma and 5 idiopathic patients. ARCO stage: 14 IIA, 33 IIB, 25 IIC. All patients underwent arthroscopic assisted minimally invasive percutaneous core decompression and bone grafting with hydroxyapatite coated titanium rod surgery. Visua Analogue Scales (VAS), Harris score and Images were used for assessing pain, hip joint function and the stability, respectively. Hip replacement was performed finally. Results: 16 patients with heavy hormone use history and femoral head collapse underwent Total Hip Resurfacing Arthroplasty (THRA) at the last follow-up. 24 months later, 8 ⅡB cases progressed to ⅡC, 2 cases were stable at ⅡC, 6 cases increased to Ⅲ, and underwent THRA. 12ⅡC cases progressed to Ⅲ, 2 cases were stable at Ⅲ, and 10 cases had articular cartilage surface collapse. THRA was administered 30 months after surgery. VAS score of individual patients increased and Harris score decreased 24 months after surgery, but there was no significant difference between the scores of 12 months and 24 months. The clinical effect of the last follow-up showed that the postoperative improvement rate of this group was 76.13%, among which the best was 100% in IIA, 79.48% in IIB, and the lowest was 58.06 in IIC. Both the patients with IIB or IIC, cases with aggravation and without change were hormonal ONFH. Conclusion: The treatment of ONFH with hydroxyapatite coated hollow titanium rod supporting the femoral head to prevent collapse is feasible. In addition to the Glucocorticoid-induced ONFH stage ⅡC outside, this method to other Ⅱ period lesions in improving the curative effect and preventing the collapse of femoral head articular surface is good and safe.


2019 ◽  
Vol 8 (5) ◽  
pp. 615 ◽  
Author(s):  
Nikolaus Wilhelm Lang ◽  
Robert Breuer ◽  
Hannes Beiglboeck ◽  
Alexandru Munteanu ◽  
Stefan Hajdu ◽  
...  

The best intramedullary nail for the treatment of unstable AO/OTA 31.A2.1-3 fractures remains uncertain. A total of 237 patients (45 male, 192 female) were eligible for the assessment with an average age of 81.9 ± 10.5 years and a minimum follow-up of six months. We assessed the cut-out rate, the TAD and calTAD (Tip Apex distance) of three different implants. An overall cut-out rate of 2.5% (n = 6) was observed. The cut-out rate was 1.2% (n = 1) in the Proximal Femur Nail Antirotation (PFNA) group, 3.7% (n = 3) in the Gamma Nail group and 2.9% (n = 2) in the Gamma3® with a U-Blade (RC) lag-screw group. The TAD and calTAD differed between the cut-out and non-cut group—20.0 mm vs. 18.5 mm and 13.1 mm vs. 15.3 mm, respectively. A significantly higher TAD of 32.5 mm could be seen in the cut-out after PFNA (p < 0.0001). The only significant change in follow-up using Parker’s ratio was observed in the PFNA group (p < 0.0001). The rate of patients requiring surgery after complications was 8.4% (n = 20) without any significant difference between the three groups. The PFNA blade showed significant migration within the femoral head, however the cut-out rate remained the smallest compared to Gamma3 with or without additional U-Blade (RC) lag screw.


2015 ◽  
Vol 9 (1) ◽  
pp. 179-184 ◽  
Author(s):  
Haixiong Miao ◽  
Dongping Ye ◽  
Weiguo Liang ◽  
Yicun Yao

Introduction: The conventional CD used 10 mm drill holes associated with a lack of structural support. Thus, alternative methods such as a tantalum implant, small drill holes, and biological treatment were developed to prevent deterioration of the joint. The treatment of CD by multiple 3.2 mm drill holes could reduce the femoral neck fracture and partial weight bearing was allowed. This study was aimed to evaluate the effect of osteonecrosis intervention rod versus core decompression using multiple small drill holes on early stages of necrosis of the femoral head. Method: From January 2011 to January 2012, 60 patients undergoing surgery for osteonecrosis with core decompression were randomly assigned into 2 groups based on the type of core decompression used: (1) a total of 30 osteonecrosis patients (with 16 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with a porous tantalum rod insertion. The diameter of the drill hole for the intervention rod was 10mm.(2) a total of 30 osteonecrosis patients (with 14 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with core decompression using five drill holes on the lateral femur, the diameter of the hole was 3.2 mm. The average age of the patient was 32.6 years (20-45 years) and the average time of follow-up was 25.6 months (12- 28 months) in the rod implanted group. The average age of the patient was 35.2 years (22- 43 years) and the average time of follow-up was 26.3 months (12-28 months) in the small drill holes group. Results: The average of surgical time was 40 min, and the mean volume of blood loss was 30 ml in both surgical groups. The average of Harris score was improved from 56.2 ± 7.1 preoperative to 80.2 ± 11.4 at the last follow-up in the rod implanted group (p < 0.05). The mean Harris score was improved from 53.8 ± 6.6 preoperative to 79.7 ± 13.2 at the last follow-up in the small drill holes group (p<0. 05). No significant difference was observed in Harris score between the two groups. At the last follow-up, 28 of 36 hips were at the same radiographic stages as pre-operation, and 8 deteriorated in the rod implanted group. 26 of 34 hips were at the same radiographic stage as pre-operation, and 8 deteriorated in the small drill holes group. No significant difference was observed in radiographic stage between the two groups. There was no favourable result on the outcome of a tantalum intervention implant compared to multiple small drill holes. Discussion: CD via multiple small drill holes would allow similar postoperative load-bearing and seems to result in similar or even better clinical outcome without the prolonged implantation of an expensive tantalum implant. A tantalum rod intervention and core decompression using multiple small drill holes were effective on the stage I hips rather than stage II hips.


2021 ◽  
Vol 22 (S2) ◽  
Author(s):  
Domenico De Mauro ◽  
Giuseppe Rovere ◽  
Amarildo Smakaj ◽  
Silvia Marino ◽  
Gianluca Ciolli ◽  
...  

Abstract Background The purpose of the study is to evaluate clinical and radiological outcomes in those patients with femoral head fracture, treated with open reduction and internal fixation through Gibson approach and Ganz flip trochanter osteotomy. The treatment of Pipkin fractures is very challenging, especially for small trauma centers, because of the unusual fracture patterns and high-level surgical skills required. Case presentation Between 2017 and 2020, nine cases of Pipkin fractures came to the Emergency Department at the Trauma Center of our Hospital in Rome. Inclusion criteria were the diagnosis of femoral head fracture, the open reduction and internal fixation as surgical choice and at least 24 months follow-up. Patients older than 65 years and those treated through total hip replacement or combined hip procedure (CHP) were excluded. Thus, five patients were included in our case series. The clinical outcome was evaluated according to Western Ontario and McMaster Universities Arthritis Index, Vail Hip score, modified Harris Hip score and Merle D’Aubignè Postel score. Radiographic assessment was scored according to Epstein-Thompson classification and heterotopic ossification was assessed through Brooker classification. The mean follow-up was 24 months (range 12-24). Average modified Harris Hip score was 92.1 points (range 75.9–100), and the average Vail score was 81.8 (range 55-95). WOMAC score was assessed in three different subscales, pain (A), stiffness (B) and physical condition (C), with the following results: 1.4 A (range 0-7), 1.2 B (range 0-6) and 6.4 C (range 0-22). Merle d’Aubignè Postel score resulted excellent for four patients and good for one patient. According to Epstein-Thompson score of the radiological outcome, four patients showed a good result and one a fair result. No mechanical or infective complications occurred in the five patients. Conclusions Gibson’s approach and surgical hip dislocation through Ganz trochanteric flip osteotomy allow a good exposure of the femoral head and acetabulum, giving us the possibility to perform an anatomical reduction of the fracture. In our case series, satisfactory clinical and radiological short-term results were obtained without significant complications.


Sign in / Sign up

Export Citation Format

Share Document