scholarly journals Combining F-Scan and GAITRite® for use in Clinical Gait Analysis: A Validation Study.

2020 ◽  
Author(s):  
Stephanie Speight ◽  
Selina Reidy ◽  
John Stephenson ◽  
Sarah Reel

Abstract BackgroundClinical gait analysis is widely used to aid the assessment and diagnosis of symptomatic pathologies. Equipment based analysis provides clinicians with a more comprehensive assessment using pressure systems such as F-scan, or analysis of the spatial-temporal parameters of gait using GAITRite. There are systems however such as Strideway™ that can measure these parameters simultaneously, but can be expensive. This study aimed to determine whether standalone systems can be used collectively while still providing quality data, as a cost-effective alternative.MethodsTwenty-six participants walked on a standard floor and a GAITRite walkway, three times wearing the F-Scan system. Mid gait protocols were utilised by analysing the contact pressure of the 2 nd metatarsophalangeal joint of the third, fifth and seventh step from each walk. The Bland-Altman method was used to determine a level of agreement between the two surfaces, using mean values from all walks of all participants who successfully completed all required walks. The intraclass correlation coefficient and Lin’s concordance correlation coefficient were calculated as indices of reliability.ResultsThe intraclass correlation coefficient was calculated to be 0.991 and Lin’s concordance correlation coefficient for the data was calculated to be 0.956, indicating very good reproducibility.ConclusionsThe level of agreement in plantar pressures observed on the two surfaces was very high, suggesting that it is feasible to use F-Scan and GAITRite® together in a clinical setting, as an alternative to other less cost-effective standalone systems.

2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1423.2-1424
Author(s):  
J. A. Mendonça ◽  
I. Siste de Almeida Aoki ◽  
C. C. Cavuto ◽  
V. A. Leandro-Merhi ◽  
J. L. B. D. Aquino

Background:The gray scale (GS) in high resolution ultrasound is already well validated for use in rheumatological diseases, but the color map or the histogram, can be considered a new proposal, to better define and complement the echotextural damages detection1.Objectives:To calculate the lesions area measures reproducibility index in arthropathies, between 3 blind evaluators and correlate these measures using the GS and the histogram.Methods:Observational and retrospective study approved by the ethics committee of the Pontifical Catholic University of Campinas, with the opinion number: 1.526.307. A total of 29 patients have been assessed (31% males and 69% females) on period 2014 to 2019 in Rheumatology service. A MyLab 50 -Esaote equipment was used with frequency transducer that ranged between 6.0 and 18.0 MHz, 10 different area measures were performed from each recorded images previously, by the GS and the histogram. Statistical analysis: Spearman’s correlation coefficients, Lin’s concordance coefficient (CCC) and the intraclass correlation coefficient (ICC) and their respective 95% confidence intervals, with the SPSS software package for Windows v. 17.0 (SPSS Inc., Chicago, IL, USA).Results:Average age 43.5 ± 21.5 years of age; with disease duration that varied between ≤ 1 month (48.3%) and ≥36 months (24.1%); with the following diseases: juvenile idiopathic arthritis (17.24%); osteoarthritis (13.79%); psoriatic arthritis (13.79%); undifferentiated spondyloarthritis (3.44%); gout (20.68%); rheumatoid arthritis (27.58%) and reactive arthritis (3.44%). A total of 840 measures of exudative (27.58%), proliferative (27.58%) and snowstorm appearance (6.89%) synovitis were performed; femoral-condyle cartilage (3.44%); synovial cyst (3.44%); paratendinitis (6.89%); calcification (3.44%); nail enthesitis (3.44%); tenosynovitis (6.89%) and tophi (10.34%) (Figure 1). The concordance correlation coefficient showed values closer to 1; p <0.001, the intraclass correlation coefficients with excellent reproducibility (ICC ≥ 0.75); p <0.001, always in relation to the three evaluators (Table 1) and the Spearman correlation between the GS and the histogram ranged from rs = 0.665 to rs = 1,000; p <0.001.Conclusion:The histogram can be considered an image method to better identify echotextural damages.References:[1]Mendonça J, Provenza J, Guissa V, et al AB1059 2D Histogram Ultrasound and 3D Ultrasound Correlation in Rheumatic Diseases Annals of the Rheumatic Diseases 2015; 74:1253-1254.Table 1.Concordance Correlation Coefficient (CCC) and Intraclass Correlation Coefficient (ICC):EvaluatorsGS - CCC(IC 95%)p-valorHistogram (IC 95%)p-valor1 e 20,998(0,994-0,999)<0,0010,999(0,995-1,000)<0,0011 e 30,998(0,995-0,999)<0,0010,999(0,995-1,000)<0,0012 e 30,992(0,980-0,997)<0,010,996(0,979-0,999)<0,01Standard by US 2DICCp-valorGS0,997(0,992-0,999)<0,001Histogram0,998(0,992-0,999)<0,001Legends: Gray Scale (GS).Figure 1.Patient with gout: A and B: Tophi area measures (star) in right metatarsos and efusion (arrow) by GS (45 mm2) and histogram (39 mm2), respectively.Disclosure of Interests:José Alexandre Mendonça Speakers bureau: Novartis, Janssen, Bristol, UCB, Isabella Siste de Almeida Aoki: None declared, Caique Chagas Cavuto: None declared, Vânia Aparecida Leandro-Merhi: None declared, José Luis Braga de Aquino: None declared


2015 ◽  
Vol 20 (2) ◽  
pp. 42-48 ◽  
Author(s):  
Pedro Lima Emmerich Oliveira ◽  
Andrea Fonseca Jardim da Motta ◽  
Clarice Julia Guerra ◽  
José Nelson Mucha

OBJECTIVE: To compare the visual analogue scale (VAS) and the simplified Q-sort method used to investigate the highest level of agreement among dentists, orthodontists and laypeople when assessing smile and dental attractiveness. MATERIAL AND METHODS: An album containing 258 photos of 86 individuals with their lips at rest, a slight and broad smile, was assessed by 25 dentists (general clinicians and various specialties), 23 orthodontists and 27 laypeople with regard to smile and dental attractiveness. To this end, both VAS and simplified Q-sort method were used. Agreements were calculated by intraclass correlation coefficient (ICC). RESULTS: For the single measurement between the VAS method and the simplified Q-sort method, all simplified Q-sort rates were higher in all groups. The simplified Q-sort method results ranged between 0.42 and 0.49 while those of the VAS method varied between 0.37 and 0.42. The simplified Q-sort method also presented higher mean measurement values (0.95 and 0.96) in comparison to VAS (0.94 and 0.95). CONCLUSIONS: Both scales may be considered reliable for evaluating smile and dental attractiveness; however, the simplified Q-Sort method presented slightly higher values than the VAS method.


Author(s):  
A. M. Imanthi C. K. Jayathilake ◽  
Lakshika S. Nawarathna ◽  
S. P. N. P. Nagarathne

Aim: The main objective of this study is to compare the development of mandibular length by comparing the effectiveness of a new low-cost arch development appliance in increasing the length of the mandible with the twin block appliance (Twin-B). Methodology: This analysis was performed on patients who attended the clinic in the Division of Orthodontics, Faculty of Dental Sciences, University of Peradeniya. The sample included 60 subjects treated with Twin-B (n=30) and new low-cost arch development (n=30) appliances and each appliance comprised 15 males and females. Intraclass Correlation Coefficient (ICC) and the Concordance Correlation Coefficient (CCC) were calculated to check the agreement between the two methods. A mixed-effects model was fitted to predict mandibular length, and Akaike Information Criterion (AIC), Bayesian Information Criterion (BIC), and log-likelihood were used for selecting the best model. Results: It was observed that the Concordance Correlation Coefficient (CCC) for after treatment as 0.9172 with a (0.8488, 0.9555) 95% confidence interval. Furthermore, it gives a Pearson correlation of 0.9609 and bias correlation factor of 0.9545. ICC values after treatment for both single measures and average measures are 0.9499 and 0.9743 with the 95% confidence intervals (0.8976, 0.9758) and (0.9460, 0.9878) respectively. Conclusion: Besides, both Twin-B and new low-cost arch development appliances have a better agreement and can be used interchangeably. Therefore, the new low-cost arch development appliance is more suitable as a treatment for malocclusion for Sri Lankan patients as it is less expensive, simpler and, less invasive.


Author(s):  
Karl Spiteri ◽  
Kate Grafton ◽  
John Xerri de Caro ◽  
David Broom

The International Physical Activity Questionnaire (IPAQ) is a widely used self-reported physical activity (PA) measure developed to allow for international cross-country comparisons. Due to its unavailability, the aim of this study was to translate the IPAQ-long to Maltese and undertake reliability testing. The IPAQ-long English version was translated into Maltese following the IPAQ guidelines, which included backwards translation. Maltese-speaking participants, aged between 18 and 69 years, were recruited through convenience sampling (n = 170). Participants completed the IPAQ-long twice within an 8- to 48-hr period. PA was calculated in MET minutes per week, and reliability was calculated using the Spearman correlation, intraclass correlation coefficient, concordance correlation coefficient, and Bland–Altman plots. A total of 155 participants completed the questionnaire at two time points. Spearman correlation was .83 (.76–.88) for total PA and .84 (.77–.89) for total sitting time. The intraclass correlation coefficient was .83 (.76–.88) and the concordance correlation coefficient was .75–.87 for total PA. The lowest reliability was for total transport, with a concordance correlation coefficient of .21−.45. Bland–Altman plots highlight that 95% of the differences fell within 2 SDs from the mean. Since the Maltese IPAQ-long has similar reliability to the English version, the authors recommend that health care professionals and PA practitioners use this tool when examining population-level PA among Maltese-speaking individuals.


Plant Disease ◽  
2019 ◽  
Vol 103 (6) ◽  
pp. 1347-1356 ◽  
Author(s):  
Emerson M. Del Ponte ◽  
Scot C. Nelson ◽  
Sarah J. Pethybridge

Two diagrammatic ordinal scales are available in the Estimate app (2017 version) for Cercospora leaf spot (CLS) severity on table beet: 10% linear (linear-based diagrammatic scale [LIN]) and logarithmic based (Horsfall–Barratt [HB]). These allow for estimating severity data of four types depending on the system used. A group of 30 raters assigned percentage severity on 30 photographs of diseased table beet leaves during five rounds first without an aid and then using each of the four rating systems in Estimate. In two, the perceived ordinal score of the HB or LIN scale was assigned where severity of the subject fit best. HB2 and LIN2 involved a second choice of unitary severity within the perceived score interval. There was large variation in unaided ability of raters to estimate severity: 13% were accurate (Lin’s concordance correlation [LCC] > 0.9), 23% were inaccurate (LCC < 0.7), and the remaining had moderate accuracy. Larger disparities between assigned and actual ordinal scores (mostly overestimates) occurred using the LIN compared with the HB. The LIN2 produced the most accurate estimates (Lin’s concordance correlation coefficient, ρc= 0.96; generalized bias parameter, Cb= 0.99; Pearson’s correlation coefficient r = 0.95) and the greatest interrater reliability (overall concordance correlation coefficient and intraclass correlation coefficient > 0.93). The two-step process using the 10% linear scale is recommended for severity estimates of CLS in table beet.


2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Bo Zhang ◽  
Jianjun Gu ◽  
Xiaoxiao Zhang ◽  
Bin Yang ◽  
Zheng Wang ◽  
...  

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device.Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment were taken at posterior pressures of 15, 30, 45, 60, and 75 mmHg by the device. The repeatability and reliability of the parameters including CCT, ACD, ACV, and CV were evaluated at each posterior pressure. All the variations of the parameters at the different posterior pressures were calculated.Results. All parameters showed good intraobserver reliability (Cronbach’s alpha; intraclass correlation coefficient,α, ICC > 0.96) and repeatability in the modified Scheimpflug device. With the increase of posterior pressures, the ratio of CCT decreased linearly and the bulk modulus gradually reduced to a platform. The increase of ACD was almost linear with the posterior pressures elevated.Conclusions. The modified Scheimpflug device was a valuable tool to investigate the biomechanics of the cornea. The posterior pressure 15–75 mmHg range produced small viscoelastic deformations and nearly linear pressure-deformation response in the rabbit cornea.


Sign in / Sign up

Export Citation Format

Share Document