scholarly journals Hepatic Arterial System- A Radioanatomical Analysis With Multidetector Computed Tomography

Author(s):  
Kalyanapanchakshari Poluri ◽  
S. K. Agarwal ◽  
R. P. Bansal
2015 ◽  
Vol 48 (6) ◽  
pp. 358-362 ◽  
Author(s):  
Severino Aires Araujo Neto ◽  
Henrique Almeida Franca ◽  
Carlos Fernando de Mello Júnior ◽  
Eulâmpio José Silva Neto ◽  
Gustavo Ramalho Pessoa Negromonte ◽  
...  

Abstract Objective: To analyze the prevalence of anatomical variations of celiac arterial trunk (CAT) branches and hepatic arterial system (HAS), as well as the CAT diameter, length and distance to the superior mesenteric artery. Materials and Methods: Retrospective, cross-sectional and predominantly descriptive study based on the analysis of multidetector computed tomography images of 60 patients. Results: The celiac trunk anatomy was normal in 90% of cases. Hepatosplenic trunk was found in 8.3% of patients, and hepatogastric trunk in 1.7%. Variation of the HAS was observed in 21.7% of cases, including anomalous location of the right hepatic artery in 8.3% of cases, and of the left hepatic artery, in 5%. Also, cases of joint relocation of right and left hepatic arteries, and trifurcation of the proper hepatic artery were observed, respectively, in 3 (5%) and 2 (3.3%) patients. Mean length and caliber of the CAT were 2.3 cm and 0.8 cm, respectively. Mean distance between CAT and superior mesenteric artery was 1.2 cm (standard deviation = 4.08). A significant correlation was observed between CAT diameter and length, and CAT diameter and distance to superior mesenteric artery. Conclusion: The pattern of CAT variations and diameter corroborate the majority of the literature data. However, this does not happen in relation to the HAS.


2016 ◽  
Vol 49 (1) ◽  
pp. 49-52 ◽  
Author(s):  
Severino Aires Araujo Neto ◽  
Carlos Fernando de Mello Júnior ◽  
Henrique Almeida Franca ◽  
Cláudia Martina Araújo Duarte ◽  
Rafael Farias Borges ◽  
...  

Abstract Although digital angiography remains as the gold standard for imaging the celiac arterial trunk and hepatic arteries, multidetector computed tomography in association with digital images processing by software resources represents a useful tool particularly attractive for its non invasiveness. Knowledge of normal anatomy as well as of its variations is helpful in images interpretation and to address surgical planning on a case-by-case basis. The present essay illustrates several types of anatomical variations of celiac trunk, hepatic artery and its main branches, by means of digitally reconstructed computed tomography images, correlating their prevalence in the population with surgical implications.


2021 ◽  
Vol 39 (3) ◽  
pp. 869-875
Author(s):  
Abdulkadir Bilir ◽  
Zeliha Fazliogullari ◽  
Mustafa Koplay ◽  
Nadire Unver-Dogan ◽  
Ahmet Kagan Karabulut

2008 ◽  
Vol 58 (3) ◽  
pp. 277
Author(s):  
Ji Sang Park ◽  
Seong Jin Park ◽  
Hae Kyung Lee ◽  
Boem Ha Yi ◽  
Hyun Sook Hong ◽  
...  

2012 ◽  
Vol 15 (1) ◽  
pp. 12 ◽  
Author(s):  
Levent Sahiner ◽  
Ali Oto ◽  
Kudret Aytemir ◽  
Tuncay Hazirolan ◽  
Musturay Karcaaltincaba ◽  
...  

<p><b>Background:</b> The aim of this study was to investigate the diagnostic accuracy of 16-slice multislice, multidetector computed tomography (MDCT) angiography for the evaluation of grafts in patients with coronary artery bypass grafting (CABG).</p><p><b>Methods:</b> Fifty-eight consecutive patients with CABG who underwent both MDCT and conventional invasive coronary angiography were included. The median time interval between the 2 procedures was 10 days (range, 1-32 days). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of MDCT for the detection of occluded grafts were calculated. The accuracy of MDCT angiography for detecting significant stenoses in patent grafts and the evaluability of proximal and distal anastomoses were also investigated.</p><p><b>Results:</b> Optimal diagnostic images could not be obtained for only 3 (2%) of 153 grafts. Evaluation of the remaining 150 grafts revealed values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy of the MDCT angiography procedure for the diagnosis of occluded grafts of 87%, 97%, 94%, 93%, and 92%, respectively. All of the proximal anastomoses were optimally visualized. In 4 (8%) of 50 patent arterial grafts, however, the distal anastomotic region could not be evaluated because of motion and surgical-clip artifacts. The accuracy of MDCT angiography for the detection of significant stenotic lesions was relatively low (the sensitivity, specificity, PPV, and NPV were 67%, 98%, 50%, and 99%, respectively). The number of significant lesions was insufficient to reach a reliable conclusion, however.</p><p><b>Conclusion:</b> Our study showed that MDCT angiography with 16-slice systems has acceptable diagnostic performance for the evaluation of coronary artery bypass graft patency.</p>


2010 ◽  
Vol 13 (3) ◽  
pp. E198-E199
Author(s):  
Yi-Chang Lin ◽  
Yi-Ting Tsai ◽  
Chih-Yuan Lin ◽  
Chung-Yi Lee ◽  
Gou-Jieng Hong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document