scholarly journals Attempts to support an immune etiology in 800 patients with direct antiglobulin test-negative hemolytic anemia

2020 ◽  
Vol 26 (4) ◽  
pp. 156-160
Author(s):  
Regina M. Leger ◽  
Asuncion Co ◽  
Penny Hunt ◽  
George Garratty
2013 ◽  
Vol 69 (2) ◽  
pp. 190-192 ◽  
Author(s):  
R.S. Sarkar ◽  
J. Philip ◽  
R.S. Mallhi ◽  
Neelesh Jain

2018 ◽  
Vol 25 (2) ◽  
pp. 170-174
Author(s):  
Hyun Jung Hong ◽  
Young Hye Cho ◽  
Jae-Young Lim ◽  
Jung Sook Yeom ◽  
Ji Sook Park ◽  
...  

2007 ◽  
Vol 0 (0) ◽  
pp. 071003000343002-???
Author(s):  
L. SHVIDEL ◽  
M. SHTALRID ◽  
A. DUEK ◽  
M. HARAN ◽  
A. BERREBI ◽  
...  

2013 ◽  
Vol 6 ◽  
pp. CCRep.S11469 ◽  
Author(s):  
Amruth R. Palla ◽  
Farhad Khimani ◽  
Michael D. Craig

Polygenic IgG autoantibodies are implicated in majority of the cases of warm autoimmune hemolytic anemia (WAIHA). In some of these cases, complement (C3) proteins accompany the IgG antibodies. WAIHA mediated by C3 alone is relatively rare. We present an interesting case of WAIHA with a direct antiglobulin test (DAT) positive for C3 but negative for IgG in a 79-year-old woman and perform an analytical literature review of the incidence and severity of this clinical entity.


Author(s):  
Cristiane da Silva Rodrigues de Araújo ◽  
Bruna Accorsi Machado ◽  
Tamaris Fior ◽  
Júlia Mognon Mattiello ◽  
Mosseli Meinhart ◽  
...  

Blood ◽  
2012 ◽  
Vol 120 (21) ◽  
pp. 5159-5159
Author(s):  
Jitendra Mohan Khungar ◽  
Hara Prasad Prasad Pati ◽  
Manoranjan Mahapatra

Abstract Abstract 5159 Introduction: Auto Immune Hemolytic Anemia (AIHA) is one of the most common types of acquired hemolytic anaemias. Its main cause is auto antibody mediated rapid destruction of RBCs. Detection of these autoantibodies to erythrocytes is of fundamental importance for diagnosis. A number of methodologies have been tried for detection & evaluation of these autoantibodies. Demonstration of a positive Direct Antiglobulin Test (DAT) against these autoantibodies is an important serological assay in the diagnosis of auto immune hemolytic anemia (AIHA). This test is also considered as pathognomonic of immune-mediated hemolysis. This routinely used direct antiglobulin test (DAT) has the disadvantage of low sensitivity and does not detect low levels of red cell auto antibodies leading sometimes to false negative results. Flow cytometry can effectively diagnose such patients of auto immune hemolytic anemia with low levels of autoantibodies. Role of flow cytometry in the diagnosis of several non-malignant haematological disorders is being explored & present study has been conducted with the same objective. Aims & Objectives: This study was conducted with the following aims and objectives: •To assess the utility of flow-cytometry (FCM) in the diagnosis of suspected AIHA patients. •Compare the sensitivity of flow-cytometry (FCM) with Direct Antiglobulin Test (DAT) by Gel-card Test (GT). •To assess the positivity in DAT negative cases by flow-cytometry in suspected AIHA cases. Material & Methods: This was a prospective study, carried out in Haematology Deptt of All India Institute of Medical Sciences, where patients with suspected auto immune hemolytic anemia (AIHA) were studied during two years period. Blood samples of suspected patients of AIHA were tested by Gel Card Test as well as by Flow cytometry for detection of RBC bound IgG. Results: A total of 50 patients with suspected diagnosis of auto immune hemolytic anemia (AIHA) were studied by flow-cytometry as well as by Gel card test (GT) for detection of RBC bound IgG. Out of these 50 cases, 41 cases have turned out to be positive and 9 were negative by flow-cytometry. The quantification of positivity by flow-cytometry was obtained by calculating percentage fluorescence. The same 50 cases were also tested by Gel card test (GT). By Gel card test, out of 50 cases, 34 were positive & 16 were negative. Therefore, there were 7 cases which were negative for RBC bound IgG by Gel card test and these were positive by flow-cytometry. The flow cytometry figures of these cases will be shown & discussed in the presentation. Conclusions: Flow-cytometry is a reliable and sensitive method of detecting RBC-bound IgG antibodies for the diagnosis of auto immune hemolytic anemia. This can be used as a new routine diagnostic technique for auto immune hemolytic anemia. Disclosures: No relevant conflicts of interest to declare.


Sign in / Sign up

Export Citation Format

Share Document