Soil Heat Flux Plates: Heat Flow Distortion and Thermal Contact Resistance

2007 ◽  
Vol 99 (1) ◽  
pp. 304-310 ◽  
Author(s):  
Thomas J. Sauer ◽  
Tyson E. Ochsner ◽  
Robert Horton
Author(s):  
B. Abdulhay ◽  
B. Bourouga ◽  
F. Alzetto ◽  
C. Challita

In this paper, an experimental device is designed and developed in order to estimate thermal conditions at the glass/metal contact interface. This device is made of two parts: The upper part contains the tool (piston) made of bronze and a heating device to raise the temperature of the piston to 700 °C. The lower part is composed of a lead crucible and a glass sample. The assembly is provided with a heating system, an induction furnace of 6 kW for heating the glass up to 950 °C. The developed experimental procedure has permitted the estimation of the thermal contact resistance (TCR) using a developed measurement principle based on the inverse technique developed by Beck et al. (1985, Inverse Heat Conduction: III Posed Problems, Wiley Inter-science, New York). The semitransparent character of the glass has been taken into account by an additional radiative heat flux and an equivalent thermal conductivity. After the set-up tests, reproducibility experiments for a specific contact pressure have been carried out. Results show a good repeatability of the registered and estimated parameters such as the piston surface temperature, heat flux density, and TCR. The estimated value of TCR reaches 2 × 10−3 K m2/W with a maximum dispersion that does not exceed 6%.


2013 ◽  
Vol 7 (3) ◽  
Author(s):  
Abdusalam Al-Khwaji ◽  
Brian Vick ◽  
Tom Diller

A new thermal perfusion probe operates by imposing a thermal event on the tissue surface and directly measuring the temperature and heat flux response of the tissue with a small sensor. The thermal event is created by convectively cooling the surface with a small group of impinging jets using room temperature air. The hypothesis of this research is that this sensor can be used to provide practical burn characterization of depth and severity by determining the thickness of nonperfused tissue. To demonstrate this capability the measurement system was tested with a phantom tissue that simulates the blood perfusion of tissue. Different thicknesses of plastic were used at the surface to mimic layers of dead tissue. A mathematical model developed by Alkhwaji et al. (2012, “New Mathematical Model to Estimate Tissue Blood Perfusion, Thermal Contact Resistance and Core Temperature,” ASME J. Biomech. Eng., 134, p. 081004) is used to determine the effective values of blood perfusion, core temperature, and thermal resistance from the thermal measurements. The analytical solutions of the Pennes bioheat equation using the Green's function method is coupled with an efficient parameter estimation procedure to minimize the error between measured and analytical heat flux. Seven different thicknesses of plastic were used along with three different flow rates of perfusate to simulate burned skin of the phantom perfusion system. The resulting values of thermal resistance are a combination of the plastic resistance and thermal contact resistance between the sensor and plastic surface. Even with the uncertainty of sensor placement on the surface, the complete set of thermal resistance measurements correlate well with the layer thickness. The values are also nearly independent of the flow rate of the perfusate, which shows that the parameter estimation can successfully separate these two parameters. These results with simulated burns show the value of this minimally invasive technique to measure the thickness of nonperfused layers. This will encourage further work with this method on actual tissue burns.


2018 ◽  
Vol 2018 (0) ◽  
pp. 0215
Author(s):  
Risako Kibushi ◽  
Kazuhisa Yuki ◽  
Tomoyuki Hatakeyama ◽  
Noriyuki Unno ◽  
Toshio Tomimuta ◽  
...  

1999 ◽  
Vol 122 (1) ◽  
pp. 46-49 ◽  
Author(s):  
Y. Z. Li ◽  
C. V. Madhusudana ◽  
E. Leonardi

A resistance to heat flow exists at the junction of two surfaces. It has long been recognized that there exists a hysteresis effect, that is, the value of thermal contact resistance in the unloading process is less than that in the loading process at the same load. However, little work has been done in utilizing this phenomenon to enhance the thermal contact conductance. The present experimental work investigated the effect of loading history; in particular the number of load cycles and overloading pressure, on the thermal contact conductance. It was found that the value of the thermal contact conductance might be enhanced by up to 51 percent. A cost-effective way of enhancing the contact conductance is suggested. [S0022-1481(00)01601-7]


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Abdusalam Alkhwaji ◽  
Brian Vick ◽  
Tom Diller

Analytical solutions were developed based on the Green’s function method to describe heat transfer in tissue including the effects of blood perfusion. These one-dimensional transient solutions were used with a simple parameter estimation technique and experimental measurements of temperature and heat flux at the surface of simulated tissue. It was demonstrated how such surface measurements can be used during step changes in the surface thermal conditions to estimate the value of three important parameters: blood perfusion (wb), thermal contact resistance (R″), and core temperature of the tissue (Tcore). The new models were tested against finite-difference solutions of thermal events on the surface to show the validity of the analytical solution. Simulated data was used to demonstrate the response of the model in predicting optimal parameters from noisy temperature and heat flux measurements. Finally, the analytical model and simple parameter estimation routine were used with actual experimental data from perfusion in phantom tissue. The model was shown to provide a very good match with the data curves. This demonstrated the first time that all three of these important parameters (wb, R″, and Tcore) have simultaneously been estimated from a single set of thermal measurements at the surface of tissue.