scholarly journals Analysis of Nucleic Acids Extracted from Rapid Diagnostic Tests Reveals a Significant Proportion of False Positive Test Results Associated with Recent Malaria Treatment

2021 ◽  
Author(s):  
Salome Hosch ◽  
Charlene Aya Yoboue ◽  
Olivier Tresor Donfack ◽  
Etienne A. Guirou ◽  
Jean-Pierre Dangy ◽  
...  
2021 ◽  
Author(s):  
Salome Hosch ◽  
Charlene Aya Yoboue ◽  
Olivier Tresor Donfack ◽  
Etienne A Guirou ◽  
Jean-Pierre Dangy ◽  
...  

Surveillance programs often use malaria rapid diagnostic tests (RDTs) to determine the proportion of the population carrying parasites in their peripheral blood to assess the malaria transmission intensity. Despite an increasing number of reports on false-negative and false-positive RDT results, there is a lack of systematic quality control activities for RDTs deployed in malaria surveillance programs. Our study provides a larger scale comparative evaluation of RDTs used in the 2018 Malaria Indicator Survey (MIS) conducted on Bioko Island, Equatorial Guinea. We conducted a molecular analysis by extraction of nucleic acids from 1,800 negative and 1,065 positive RDTs followed by qPCR analysis. These results were combined with a dataset collected in a comprehensive questionnaire from each MIS participant. Of the 2,865 RDTs that were collected in 2018 on Bioko Island and analysed in our study, 4.7% had a false-negative result. These false-negative RDT results were associated with low parasite density infections. In a substantial proportion of samples, we identified masked pfhrp2 and pfhrp3 gene deletions in which at least one P. falciparum strain carried a gene deletion. Among all positive RDTs analysed, 28.4% were tested negative by qPCR and therefore considered to be false-positive. Analysing the questionnaire data collected from the participants, this high proportion of false-positive RDT results could be explained by PfHRP2 antigen persistence after recent malaria treatment. We conclude that malaria surveillance depending solely on RDTs needs well-integrated quality control procedures assessing the extend and impact of reduced sensitivity and specificity of RDTs on malaria control programs.


2020 ◽  
Vol 308 ◽  
pp. 110165
Author(s):  
Megan M. Foley ◽  
Catherine O. Brown ◽  
Christian G. Westring ◽  
Phillip B. Danielson ◽  
Heather E. McKiernan

2015 ◽  
Vol 175 (2) ◽  
pp. 161
Author(s):  
Simina R. Luca ◽  
Mandana Kayedi ◽  
Brian M. Wong

Transfusion ◽  
2011 ◽  
Vol 51 (7) ◽  
pp. 1595-1596
Author(s):  
Patrícia R. Araújo ◽  
Guilherme A. Albertoni ◽  
Silvia R. Rizzo ◽  
Fabrício O. Carvalho ◽  
José A. Barreto

1999 ◽  
Vol 37 (1) ◽  
pp. 175-178 ◽  
Author(s):  
James H. Jorgensen ◽  
Jesse R. Salinas ◽  
Rosemary Paxson ◽  
Karen Magnon ◽  
Jan E. Patterson ◽  
...  

The Gen-Probe Amplified Mycobacterium Tuberculosis Direct (MTD) test has been approved for use in the United States for the rapid diagnosis of pulmonary tuberculosis in patients with acid-fast smear-positive sputum samples since 1996. Four patients infected with human immunodeficiency virus and one chronic pulmonary-disease patient seen in our institutions with abnormal chest radiographs and fluorochrome stain-positive sputa were evaluated for tuberculosis, including performance of the MTD test on expectorated sputum samples. Three of these five patients’ sputa were highly smear-positive (i.e., more than 100 bacilli per high-power field), while two patient’s sputa contained 1 to 10 bacilli per field. MTD results on sputum specimens from these patients ranged from 43,498 to 193,858 relative light units (RLU). Gen-Probe has defined values of at least 30,000 RLU as indicative of a positive test, i.e., the presence ofMycobacterium tuberculosis RNA. Four of the patients’ sputum cultures yielded growth of M. kansasii within 6 to 12 days, and the fifth produced growth of M. avium only. One patient’s culture contained both M. kansasii andM. avium, but none of the initial or follow-up cultures from these five patients revealed M. tuberculosis. However, subsequent cultures from three of the patients again revealed M. kansasii. During the period of this study, in which MTD tests were performed on smear-positive sputum specimens from 82 patients, four of seven patients with culture-proven M. kansasiipulmonary infections yielded one or more false-positive MTD tests. The MTD sensitivity observed in this study was 93.8%, and the specificity was 85.3%. Five cultures of M. kansasii (including three of these patients’ isolates and M. kansasii ATCC 12478), and cultures of several other species were examined at densities of 105 to 107 viable CFU/ml by the MTD test. All five isolates of M. kansasii and three of three isolates ofM. simiae yielded false-positive test results, with readings of 75,191 to 335,591 RLU. These findings indicate that low-level false-positive MTD results can occur due to the presence ofM. kansasii, M. avium, and possibly otherMycobacterium species other than M. tuberculosis in sputum. Low-level positive MTD results of 30,000 to 500,000 RLU should be interpreted in light of these findings. It remains to be determined if the enhanced MTD test (MTD 2) recently released by Gen-Probe will provide greater specificity than that observed in this report with its first-generation test.


mSphere ◽  
2020 ◽  
Vol 5 (1) ◽  
Author(s):  
Carlo Fischer ◽  
Fernando Bozza ◽  
Xiomara Jeanleny Merino Merino ◽  
Celia Pedroso ◽  
Edmilson F. de Oliveira Filho ◽  
...  

ABSTRACT Since 2013, the arthropod-borne Chikungunya virus (CHIKV) has cocirculated with the autochthonous Mayaro virus (MAYV) in Latin America. Both belong to the same alphavirus serocomplex, termed the Semliki Forest serocomplex. The extent of antibody cross-reactivity due to the antigenic relatedness of CHIKV and MAYV in commonly used serologic tests remains unclear. By testing 64 CHIKV- and 37 MAYV-specific sera from cohort studies conducted in Peru and Brazil, we demonstrate about 50% false-positive test results using commercially available enzyme-linked immunosorbent assays (ELISAs) based on structural antigens. In contrast, combining ELISAs for CHIKV and MAYV significantly increased positive predictive values (PPV) among all cohorts from 35.3% to 88.2% for IgM and from 61.3% to 96.8% for IgG (P < 0.0001). Testing of longitudinally collected CHIKV-specific patient sera indicated that ELISA specificity is highest for IgM testing at 5 to 9 days post-onset of symptoms (dpo) and for IgG testing at 10 to 14 dpo. IgG cross-reactivity in ELISA was asymmetric, occurring in 57.9% of MAYV-specific sera compared to 29.5% of CHIKV-specific sera. Parallel plaque reduction neutralization testing (PRNT) for CHIKV and MAYV increased the PPV from 80.0% to 100% (P = 0.0053). However, labor-intense procedures and delayed seroconversion limit PRNT for patient diagnostics. In sum, individual testing for CHIKV or MAYV only is prone to misclassifications that dramatically impact patient diagnostics and sero-epidemiologic investigation. Parallel ELISAs for both CHIKV and MAYV provide an easy and efficient solution to differentiate CHIKV from MAYV infections. This approach may provide a template globally for settings in which alphavirus coemergence imposes similar problems. IMPORTANCE Geographically overlapping transmission of Chikungunya virus (CHIKV) and Mayaro virus (MAYV) in Latin America challenges serologic diagnostics and epidemiologic surveillance, as antibodies against the antigenically related viruses can be cross-reactive, potentially causing false-positive test results. We examined whether widely used ELISAs and plaque reduction neutralization testing allow specific antibody detection in the scenario of CHIKV and MAYV coemergence. For this purpose, we used 37 patient-derived MAYV-specific sera from Peru and 64 patient-derived CHIKV-specific sera from Brazil, including longitudinally collected samples. Extensive testing of those samples revealed strong antibody cross-reactivity in ELISAs, particularly for IgM, which is commonly used for patient diagnostics. Cross-neutralization was also observed, albeit at lower frequencies. Parallel testing for both viruses and comparison of ELISA reactivities and neutralizing antibody titers significantly increased diagnostic specificity. Our data provide a convenient and practicable solution to ensure robust differentiation of CHIKV- and MAYV-specific antibodies.


Sign in / Sign up

Export Citation Format

Share Document