cement type
Recently Published Documents


TOTAL DOCUMENTS

281
(FIVE YEARS 73)

H-INDEX

28
(FIVE YEARS 5)

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 424
Author(s):  
Nourhan Samy ◽  
Walid Al-Zordk ◽  
Ahmed Elsherbini ◽  
Mutlu Özcan ◽  
Amal Abdelsamad Sakrana

This paper assesses the effect of cement type and cement preheating on the marginal and internal fit of lithium disilicate single crown. Methods: 40 maxillary premolars were selected, restored with lithium disilicate single crowns. Teeth were randomly assigned into four groups (n = 10) based on cement type (Panavia SA or LinkForce) and preheating temperature (25 °C or 54 °C). After fabrication of the restoration, cements were incubated at 25 °C or 54 °C for 24 h, and each crown was cemented to its corresponding tooth. After 24 h, all specimens were thermally aged to (10,000 thermal cycles between 5 °C and 55 °C), then load cycled for 240,000 cycles. Each specimen was then sectioned in bucco-palatal direction and inspected under a stereomicroscope at x45 magnification for marginal and internal fit evaluation. The data were statistically analyzed (significance at p ≤ 0.05 level). Results: At the mid-buccal finish line, mid-buccal wall, palatal cusp, mid-palatal wall, mid-palatal finish line, and palatal margin measuring points, there was a significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 25 °C and the group cemented with LinkForce at 25 °C, while there was no significant difference (p > 0.05) at the other points. At all measuring points, except at the palatal cusp tip (p = 0.948) and palatal margin (p = 0.103), there was a statistically significant difference (p ≤ 0.05) between the lithium disilicate group cemented with Panavia SA at 54 °C and the group cemented with LinkForce at 54 °C. Regardless of cement preheating, statistically significant differences were found in the buccal cusp tip, central groove, palatal cusp tip, and mid-palatal wall (p ≤ 0.05) in the lithium disilicate group cemented with Panavia SA at 25 °C and 54 °C, as well as the mid-palatal chamfer finish line and palatal margin in the LinkForce group cemented with Panavia SA at 25 °C and 54 °C. At the other measurement points, however, there was no significant difference (p > 0.05). Conclusions: The type of resin cement affects the internal and marginal fit of lithium disilicate crowns. At most measuring points, the cement preheating does not improve the internal and marginal fit of all lithium disilicate crowns.


Author(s):  
Ronaldas Jakubovskis ◽  
Augusta Ivaškė ◽  
Jurgita Malaiškienė ◽  
Jaunius Urbonavičius

Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7634
Author(s):  
Edyta Spychał ◽  
Przemysław Czapik

In this article, the effect of cement type on selected properties of plastering mortars containing a cellulose ether admixture was studied. In the research, commercial CEM I Portland cement, CEM II and CEM III, differing in the type and amount of mineral additives, and cement class, were used as binders. Tests of consistency, bulk density, water retention value (WRV), mechanical properties and calorimetric tests were performed. It was proved that the type of cement had no effect on water retention, which is regulated by the cellulose ether. All mortars modified with the admixture were characterized by WRV of about 99%. High water retention is closely related to the action of the cellulose ether admixture. As a result of the research, the possibility of using cement with additives as components of plasters was confirmed. However, attention should be paid to the consistency, mechanical properties of the tested mortars and changes in the pastes during the hydration process. Different effects of additives resulted from increasing or decreasing the consistency of mortars; the flow was in the range from 155 mm to 169 mm. Considering the compressive strength, all plasters can be classified as category III or IV, because the mortars attained the strength required by the standard, of at least 3.5 MPa. The processes of hydration of pastes were carried out with different intensity. In conclusion, the obtained results indicate the possibility of using CEM II and CEM III cements to produce plastering mortars, without changing the effect of water retention.


Author(s):  
Namdeo Prabhu ◽  
Amjad Abdulrahman S. Albulayhid ◽  
Abdulaziz Abdolah Y. Althari ◽  
Talal Eid Q. Alruwaili

Fixed partial dentures (FPDs) made of metal ceramic are a popular treatment option for missing teeth. Studies have shown that posterior abutments of FPDs had a higher pulp survival rate than anterior abutments. Postoperative sensitivity following the cementation of a fixed prosthesis is a frequent symptom, especially when the abutments include important pulp. Dentinal hypersensitivity affects between 4 and 74 percent of people. Females are found to have a somewhat greater DH incidence than males. While DH can affect individuals of any age, there have been several theories on what causes abutment sensitivity after tooth preparation and cementation. In this review we included some of it. Also, we discussed methods of management of postoperative sensitivity and Management of fractured abutment screw.


Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5603
Author(s):  
Amal Abdelsamad Sakrana ◽  
Walid Al-Zordk ◽  
Heba El-Sebaey ◽  
Ahmed Elsherbini ◽  
Mutlu Özcan

This paper assesses the impact of preheating of adhesive cement on the fracture resistance of lithium disilicate and zirconia restorations. Methods: A total of 80 human maxillary premolar teeth were assigned into 8 groups (n = 10) according to material type (either lithium disilicate or zirconia) and type of resin cement (either LinkForce or Panavia SA) with preheating temperature at 54 °C or at room temperature (25 °C). Teeth were prepared and restored with either lithium disilicate or zirconia restorations. After cementation, specimens were thermal cycled (10,000 cycles, 5 °C̸55 °C), then load cycled for 240,000 cycles (50 N). Each specimen was statically loaded until fracture and the load (N) at fracture was recorded, then the failure mode was detected. Statistical analysis of data was performed (p ≤ 0.05). Results: There was no significant difference (p = 0.978) in fracture mean values between LinkForce and Panavia SA. Statistically significant difference (p = 0.001) was revealed between fracture resistance of lithium disilicate restorations cemented with LinkForce at 25 °C and at 54 °C; however there was no significant difference (p = 0.92) between the fracture resistance of lithium disilicate restorations cemented with Panavia SA used at 25 °C and at 54 °C. Regarding the interaction between ceramic material, cement type, and cement preheating, there was no significant effect (p > 0.05) in fracture resistance. The cement type does not influence the fracture resistance of ceramic restorations. Preheating of resin cement has negatively influenced the fracture resistance of all tested groups, except for lithium disilicate cemented using LinkForce cement.


2021 ◽  
pp. 1815-1821
Author(s):  
Bohdan Dołżycki ◽  
Mariusz Jaczewski ◽  
Cezary Szydłowski
Keyword(s):  

2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Behnaz Ebadian ◽  
Amirhossein Fathi ◽  
Melika Savoj

Introduction. Discrepancy between the crown border and prepared tooth margin leads to a microleakage that eases the penetration of microorganisms and causes the dissolution of luting cement consequently. Several factors should be considered to achieve optimal fitness, including tooth preparation taper and type of cementing agent. The study aimed to determine the relation of tooth preparation taper and cement type on the microleakage of zirconia crowns. Materials and Methods. Fifty-six freshly extracted premolars without caries and restorations were selected as the study sample and divided into two groups of different tapering degrees (6 and 12 degrees). Zirconia copings were designed and fabricated by the CAD/CAM system. The samples were divided into four subgroups for cementation, and each subgroup was cemented with a different luting cement (n = 7). After 5000 thermocycles at 5°C–55°C and dye penetration, the specimens were sectioned in the mid-buccolingual direction, and a digital photograph of each section was taken under a stereomicroscope. Data were analyzed by the Kruskal–Wallis and Mann–Whitney tests (α = 0.05). Results. The results showed significant differences among the four types of luting cement in marginal permeability (PV < 0.001). Regardless of the type of cement, the 12-degree tapering resulted in a lower microleakage (46.4% without microleakage) with statistically significant differences from the 6-degree tapering (PV = 0.042). Conclusion. Within the limitations of this study, increasing the tapering degree of the prepared tooth for CAD/CAM zirconia copings improved the marginal fit and decreased the microleakage score. In addition, total-etch resin cement indicated the least microleakage.


2021 ◽  
Vol 321 ◽  
pp. 15-21
Author(s):  
Martin Ťažký ◽  
Rudolf Hela

The continuous tightening of emission limits for the production of harmful substances into the air and the rising price of emission allowances gradually force construction material producers to limit the use of binders with a high content of Portland clinker. In the production of concrete, this is achieved by using admixtures, which make it possible to reduce Portland cement doses. However, the single European market uses a method that maximises the use of blened cements, making it easier for cement plants to meet emission limits while not reducing cement production. The performed experiment focused on the possibility of using CEM II and CEM III cements and their comparison with CEM I cement not only in terms of the physical–mechanical parameters of concrete but also in terms of the stability of concrete mixtures made from these cements. The stability of concrete mixtures was monitored using the water separation value in the pressure method. In the experiment, the relationship between water separation and physical parameters of cement was explored.


Sign in / Sign up

Export Citation Format

Share Document