scholarly journals Review of Steel Stud Wall Systems Behavior under Blast Loads

Author(s):  
Mohamed Abo El Fotouh ◽  
Mahmoud Nawar ◽  
Atef Amin
Keyword(s):  
2011 ◽  
Vol 82 ◽  
pp. 479-484
Author(s):  
Thomas J. Mander ◽  
Zachery I. Smith

Based on Federal Aviation Authority (FAA) requirements, project specific blast loads are determined for the design of a new airport traffic control tower. These blast loads must be resisted by exterior wall panels on the control tower, protecting building occupants from intentional explosives attack scenarios. Such blast resistant walls are typically constructed of thick reinforced concrete panels or composite steel plate and rolled sections, as conventional building cladding systems have relatively low blast resistance. While these more robust design approaches are valid, the additional cladding mass they represent will significantly increase the base shear and overturning demand in seismic zones. This paper investigates the use of a light structural system comprised of a steel stud wall assembly partially embedded in a thin layer of concrete to obtain composite action. Fiber reinforced polymer (FRP) composites are also included to increase the blast resistance and aid in keeping the panel weight to a minimum. Two full-scale composite steel stud walls are designed, constructed, and tested dynamically in the BakerRisk shock tube. The stud walls consist of back-to-back 150 mm deep, 14 gauge (1.8 mm thick), cold-formed steel studs spaced at 610 mm on center. Both specimens have a 50 mm thick normal weight concrete layer, reinforced with welded wire mesh that is welded to the stud compression flanges to achieve composite action. Two layers of Tyfo® SEH-51A fiber reinforced composites are used on the tension flange of the steel studs. A single layer of Tyfo® SEH-51A composites is used on the tension face of the concrete layer between the studs for one of the specimens. Web stiffeners are used at the bearing support to prevent premature web crippling shear failure of the specimens. The stud walls are analyzed using single-degree-of-freedom (SDOF) models. A non-linear moment-curvature relationship, accounting for actual material constitutive properties, is used for determining the resistance function of the walls. Blast pressure and impulse data from the shock tube tests is used to compare analytical predictions to the measured displacement-time response. Analytical predictions of panel response for both tests are within ten percent of the observed response based on displacement.


Author(s):  
Bryan Bewick ◽  
John Hoemann ◽  
Eric Williamson
Keyword(s):  

2012 ◽  
Vol 52 (1) ◽  
pp. 197-203 ◽  
Author(s):  
Ionel Chirica ◽  
Doina Boazu ◽  
Elena-Felicia Beznea

Author(s):  
Lihong Yang ◽  
Xuyang Li ◽  
Fan Zi ◽  
Shijie Yang ◽  
Zexu Zhang ◽  
...  

2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Ravi Mudragada ◽  
S. S. Mishra

AbstractMany researchers have carried out experimental and numerical investigations to examine building structures’ response to explosive loads. Studies of bridges subjected to blast loads are limited. Hence, in this study, we present a case study on a cable-stayed bridge, namely, Charles River Cable-Stayed Bridge-Boston, to assess its robustness and resistance against the progressive collapse resulting from localized failure due to blast loads. Three different blast scenarios are considered to interpret the bridge performance to blast loads. To monitor the progressive failure mechanisms of the structural elements due to blast, pre-defined plastic hinges are assigned to the bridge deck. The results conclude that the bridge is too weak to sustain the blast loads near the tower location, and the progressive collapse is inevitable. Hence, to preserve this cable-stayed bridge from local and global failure, structural components should be more reinforced near the tower location. This case study helps the designer better understand the need for blast resistance design of cable-stayed bridges.


Sign in / Sign up

Export Citation Format

Share Document