scholarly journals Promoting equitable water distribution system from Melamchi Water Supply Project in Kathmandu Valley

2020 ◽  
Vol 20 (8) ◽  
pp. 2964-2970
Author(s):  
D. P. Ayadi ◽  
A. Rai ◽  
A. Pandey

Abstract The effective and efficient supply of drinking water resources are key to its long-term use and access. In recent decades, the population of Kathmandu Valley has exploded owing to several factors. The water supply system here has also undergone remarkable changes and efforts have been made to enhance its equitable distribution. The major effort, of course, is the Melamchi Water Supply Project (MWSP). As the project approaches completion of its first phase, we would like to point out several key issues for the water distribution system here and express our opinions on promoting equitable water distribution. For this we conducted a thorough literature review and found that improvement in the water distribution network and water tariff in the valley, along with promotion of alternative mitigation options, are the focal issues for promoting an equitable water distribution system in Kathmandu Valley.

Author(s):  
Marianna D'Ercole ◽  
Maurizio Righetti ◽  
Gema Raspati ◽  
Paolo Bertola ◽  
Rita Maria Ugarelli

The management of existing water distribution system (WDS) is challenged by ageing of infrastructure, population growth, increasing of urbanization, climate change impacts and environmental pollution. Therefore, there is a need for integrated solutions that support decision makers to plan today, while taking into account the effect of these factors in the mid and long term. The paper is part of a more comprehensive project, where advanced hydraulic analysis for WDS is coupled with a dynamic resources input-output analysis model. The proposed modeling solution can be used to optimize the performance of a water supply system while considering also the energy consumption and consequently the environmental impacts. Therefore, as a support tool in the management of a water supply system also in the intervention planning. Here a possible application is presented for rehabilitation/replacement planning while maximizing the network mechanical reliability and minimizing risk of unsupplied demand and pressure deficit, under given economic constraints.


Energies ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 6221
Author(s):  
Jedrzej Bylka ◽  
Tomasz Mróz

The water supply system is one of the most important elements in a city. Currently, many cities struggle with a water deficit problem. Water is a commonly available resource and constitutes the majority of land cover; however, its quality, in many cases, makes it impossible to use as drinking water. To treat and distribute water, it is necessary to supply a certain amount of energy to the system. An important goal of water utility operators is to assess the energy efficiency of the processes and components. Energy assessments are usually limited to the calculation of energy dissipation (sometimes called “energy loss”). From a physical point of view, the formulation of “energy loss” is incorrect; energy in water transport systems is not consumed but only transformed (dissipated) into other, less usable forms. In the water supply process, the quality of energy—exergy (ability to convert into another form)—is consumed; hence, a new evaluation approach is needed. The motivation for this study was the fact that there are no tools for exergy evaluation of water distribution systems. A model of the exergy balances for a water distribution system was proposed, which was tested for the selected case studies of a water supply system and a water treatment station. The tool developed allows us to identify the places with the highest exergy destructions. In the analysed case studies, the highest exergy destruction results from excess pressure (3939 kWh in a water supply system and 1082 kWh in a water treatment plant). The exergy analysis is more accurate for assessing the system compared to the commonly used energy-based methods. The result can be used for assessing and planning water supply system modernisation.


The study presents the hydraulic design and analysis of Rural Water Distribution System (WDS) for Nava shihora region of zone 1 of the state of Gujarat, India. Water supply distribution system is designed for this study for population estimated for future 30 years. LOOP 4.0 and Water Gems v8i software have been used and the results are compared to determine the economical size of pipes for water distribution system. The economical size of pipes of water supply distribution system is designed by considering the constraints; residual pressure at each node, velocity of flow in pipe, head loos in pipes, material of pipes, elevated service reservoir level, peak factor and available commercial pipe diameters. Further water distribution system has been analyzed for extended period simulation (EPS) for the present population scenario for intermittent water supply using Water Gems v8i. Further water supply system is analyzed the residual chlorine concentration at nodes and in the pipe links and also the total cost of water supply system of rural region is estimated.


Author(s):  
Marianna D'Ercole ◽  
Maurizio Righetti ◽  
Gema Raspati ◽  
Paolo Bertola ◽  
Rita Maria Ugarelli

The management of existing water distribution system (WDS) is challenged by ageing of infrastructure, population growth, increasing of urbanization, climate change impacts and environmental pollution. Therefore, there is a need for integrated solutions that support decision makers to plan today, while taking into account the effect of these factors in the mid and long term. The paper is part of a more comprehensive project, where advanced hydraulic analysis for WDS is coupled with a dynamic resources input-output analysis model. The proposed modeling solution can be used to optimize the performance of a water supply system while considering also the energy consumption and consequently the environmental impacts. Therefore, as a support tool in the management of a water supply system also in the intervention planning. Here a possible application is presented for rehabilitation/replacement planning while maximizing the network mechanical reliability and minimizing risk of unsupplied demand and pressure deficit, under given economic constraints.


2015 ◽  
Vol 11 (6) ◽  
pp. 731-745 ◽  
Author(s):  
Davide Marchini ◽  
Marta Rinaldi ◽  
Roberto Montanari ◽  
Eleonora Bottani ◽  
Federico Solari

Abstract This paper builds upon the study by Marchini et al. (2014, International Journal of Food Engineering, pp. 557–571) and represents the second part of a research project whose general aim was to analyse and optimize, through simulation, the water distribution system of a dairy company. In the first paper, the authors focused on finding opportunities for recycling water in the distribution system of the targeted company, i.e. a dairy company located near Parma (Italy) and manufacturing Parmigiano Reggiano cheese and butter. In this work, we go ahead by analysing the thermal properties (such as, primarily, the temperature) of the water used inside the distribution system and of that discharged. To this purpose, we add the relevant thermal equations to the MS ExcelTM simulation model developed in the first study. The resulting model is able to derive the temperature trend of water inside all the tanks of the distribution system. Situations where the temperature of the water used for rinsing is higher than the maximum allowed value of approx. 25°C are also highlighted and suggestions for improvement are proposed.


2019 ◽  
Vol 97 ◽  
pp. 05020
Author(s):  
Artur Khachatryan ◽  
Emil Khachatryan

Risks in the water distribution system in the Armenian village of Noratus, have been assessed and treated following a risk management study based on the ISO 31 000:2009 standards, but extended for a strategic and long term level of analysis. The main goal is to ensure the safety of the whole water supply system. The brief description of the region as well as the current condition of the water supply system is given in order to clarify system features. The risk management here presented approach is now implemented in the Noratus network. Simulation have been performed using the AWARE-P software platform with the purpose of identifying critical components in the network and the asset probability of structural failure, as inputs for risk quantification. Then the risk magnitude is evaluated with the introduction of risk matrix. The phases of risk estimation and treatment are also carried out to propose the solutions for risk level reduction.


2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


Sign in / Sign up

Export Citation Format

Share Document