Performance and behaviour of planted and unplanted units of a horizontal subsurface flow constructed wetland system treating municipal effluent from a UASB reactor

2013 ◽  
Vol 68 (7) ◽  
pp. 1495-1502 ◽  
Author(s):  
Jocilene Ferreira da Costa ◽  
André Cordeiro de Paoli ◽  
Martin Seidl ◽  
Marcos von Sperling

A system composed of two horizontal subsurface flow constructed wetlands operating in parallel was evaluated for the post-treatment of UASB (upflow anaerobic sludge blanket) reactor effluent, for a population equivalent of 50 inhabitants per unit. One unit was planted with cattail (Typha latifolia) and the other was unplanted. The study was undertaken over a period of 4 years, comprising monitoring of influent and effluent constituents together with a full characterization of the behaviour of the units (tracer studies, mathematical modelling of chemical oxygen demand (COD) decay, characterization of solids in the filter medium). The mean value of the surface hydraulic load was 0.11 m3m−2d−1, and the theoretical hydraulic retention time was 1.1 d in each unit. Using tracer tests with 82Br, dispersion number (d) values of 0.084 and 0.079 for the planted and unplanted units were obtained, indicating low to moderate dispersion. The final effluent had excellent quality in terms of organic matter and suspended solids, but the system showed low capacity for nitrogen removal. Four-year mean effluent concentration values from the planted and unplanted units were, respectively: biochemical oxygen demand (BOD5): 25 and 23 mg L−1; COD: 50 and 55 mg L−1; total suspended solids (TSS): 9 and 9 mg L−1; N-ammonia: 27 and 28 mg L−1. The COD decay coefficient K for the traditional plug-flow model was 0.81 and 0.84 d−1 for the planted and unplanted units. Around 80% of the total solids present in the filter medium were inorganic, and most of them were present in the interstices rather than attached to the support medium. As an overall conclusion, horizontal subsurface flow wetlands can be a very suitable post-treatment method for municipal effluents from anaerobic reactors.

2009 ◽  
Vol 60 (12) ◽  
pp. 3025-3033 ◽  
Author(s):  
Filipe Lima Dornelas ◽  
Matheus Boechat Machado ◽  
Marcos von Sperling

A system comprised by a UASB (Upflow Anaerobic Sludge Blanket) reactor followed by two horizontal subsurface-flow constructed wetlands in parallel was evaluated for the treatment of the wastewater generated in the city of Belo Horizonte, Brazil (50 inhabitants each unit). One unit was planted (Typha latifolia) and the other was unplanted. Influent and effluent samples were collected for a period of seven months. The systems were able to produce final effluents with low concentrations of organic matter and suspended solids, but showed not to be efficient in the removal of nutrients. Mean effluent concentrations for the planted and unplanted units were, respectively: BOD: 15 and 19 mg/L; COD: 42 and 64 mg/L; TSS: 3 and 5 mg/L; TN: 27 and 33 mg/L; N-NH3: 25 and 29 mg/L; P Total: 1.2 and 1.5 mg/L. The planted wetland presented effluent concentrations and removal efficiencies significantly (Wilcoxon matched-pairs test, 5% significance level) better than the unplanted unit for most constituents. The study shows that horizontal subsurface-flow constructed wetlands can be effectively used as a post-treatment option for the effluent from UASB reactors.


2012 ◽  
Vol 2 (2) ◽  
pp. 59-67 ◽  
Author(s):  
P. C. Vieira ◽  
M. von Sperling

We aimed to evaluate the performance and cost savings of an innovative design of a trickling filter (TF) for small population sizes, developed at the Federal University of Minas Gerais, Brazil referred to as an open trickling filter (OTF). The OTF had no side walls and no perforated bottom slab, and was applied for the post-treatment of sanitary sewage from an upflow anaerobic sludge blanket (UASB) reactor. The OTF had crushed-stone packing (3.5 m high) and was operated with an average surface hydraulic loading rate of 4.1 m3 m−2 d−1 and an average volumetric organic loading rate of 0.10 kg BOD m−3 d−1 (biochemical oxygen demand). The average concentrations obtained at the OTF effluent were 48 mg TSS L−1 (total suspended solids), 132 mg COD L−1 (chemical oxygen demand), 51 mg BOD L−1, 19 mg TKN L−1 (total Kjeldahl nitrogen), 16 mg NH4+-N L−1 and 10 mg NO3−-N L−1, complying with local discharge standards. Analysis of the construction costs indicated savings of 74% compared to conventional TF. Based on the performance, compactness, simplicity and reduced capital costs, it is believed that the proposed OTF is a good alternative for small communities, especially in developing countries.


2020 ◽  
Vol 81 (9) ◽  
pp. 1951-1960 ◽  
Author(s):  
C. S. Cabral ◽  
A. L. Sanson ◽  
R. J. C. F. Afonso ◽  
C. A. L. Chernicharo ◽  
J. C. Araújo

Abstract Two bioreactors were investigated as an alternative for the post-treatment of effluent from an upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage, aiming at dissolved sulfide and methane removal. The bioreactors (R-control and R-air) were operated at different hydraulic retention times (HRT; 6 and 3 h) with or without aeration. Large sulfide and methane removal efficiencies were achieved by the microaerated reactor at HRT of 6 h. At this HRT, sulfide removal efficiencies were equal to 61% and 79%, and methane removal efficiencies were 31% and 55% for R-control and R-air, respectively. At an HRT of 3 h, sulfide removal efficiencies were 22% (R-control) and 33% (R-air) and methane removal did not occur. The complete oxidation of sulfide, with sulfate formation, prevailed in both phases and bioreactors. However, elemental sulfur formation was more predominant at an HRT of 6 h than at an HRT of 3 h. Taken together, the results show that post-treatment improved the anaerobic effluent quality in terms of chemical oxygen demand and solids removal. However, ammoniacal nitrogen was not removed due to either the low concentration of air provided or the absence of microorganisms involved in the nitrogen cycle.


2014 ◽  
Vol 71 (3) ◽  
pp. 329-337 ◽  
Author(s):  
M. von Sperling

This paper presents a comparison between three simple sewage treatment lines involving natural processes: (a) upflow anaerobic sludge blanket (UASB) reactor–three maturation ponds in series–coarse rock filter; (b) UASB reactor–horizontal subsurface-flow constructed wetland; and (c) vertical-flow constructed wetlands treating raw sewage (first stage of the French system). The evaluation was based on several years of practical experience with three small full-scale plants receiving the same influent wastewater (population equivalents of 220, 60 and 100 inhabitants) in the city of Belo Horizonte, Brazil. The comparison included interpretation of concentrations and removal efficiencies based on monitoring data (organic matter, solids, nitrogen, phosphorus, coliforms and helminth eggs), together with an evaluation of practical aspects, such as land and volume requirements, sludge production and handling, plant management, clogging and others. Based on an integrated evaluation of all aspects involved, it is worth emphasizing that each system has its own specificities, and no generalization can be made on the best option. The overall conclusion is that the three lines are suitable for sewage treatment in small communities in warm-climate regions.


2011 ◽  
Vol 64 (10) ◽  
pp. 1959-1966 ◽  
Author(s):  
K. Syutsubo ◽  
W. Yoochatchaval ◽  
I. Tsushima ◽  
N. Araki ◽  
K. Kubota ◽  
...  

In this study, continuous operation of a pilot-scale upflow anaerobic sludge blanket (UASB) reactor for sewage treatment was conducted for 630 days to investigate the physical and microbial characteristics of the retained sludge. The UASB reactor with a working volume of 20.2 m3 was operated at ambient temperature (16–29 °C) and seeded with digested sludge. After 180 days of operation, when the sewage temperature had dropped to 20 °C or lower, the removal efficiency of both total suspended solids (TSS) and total biochemical oxygen demand (BOD) deteriorated due to washout of retained sludge. At low temperature, the cellulose concentration of the UASB sludge increased owing to the rate limitation of the hydrolytic reaction of suspended solids in the sewage. However, after an improvement in sludge retention (settleability and concentration) in the UASB reactor, the process performance stabilized and gave sufficient results (68% of TSS removal, 75% of total BOD removal) at an hydraulic retention time (HRT) of 9.7 h. The methanogenic activity of the retained sludge significantly increased after day 246 due to the accumulation of Methanosaeta and Methanobacterium following the improvement in sludge retention in the UASB reactor. Acid-forming bacteria from phylum Bacteroidetes were detected at high frequency; thus, these bacteria may have an important role in suspended solids degradation.


2017 ◽  
Vol 38 (6) ◽  
pp. 3705
Author(s):  
Luciano Dos Santos Rodrigues ◽  
Ana Cristina Araujo Pinto ◽  
Joyce Da Cruz Ferraz Dutra ◽  
Renata Rodrigues Sampaio ◽  
Stella Rubim de Sousa ◽  
...  

The purpose of this study was to assess the swine wastewater treatment system, consisting of the anaerobic baffled reactor (ABR), followed by the upflow anaerobic sludge blanket (UASB) reactor at full scale. The system was monitored by analyzing samples collected in the influent and effluent of ABR and UASB. The following parameters were analyzed: temperature, pH, total suspended solids (TSS), volatile suspended solids (VSS), biochemical oxygen demand (BOD), and chemical oxygen demand (COD). Averages of total removal of COD and BOD were 96.7 and 98.4%, respectively. The mean concentrations of COD, BOD, TSS, and VSS at the final effluent were 611, 124, 138, and 134 mg L-1, respectively. The mean volumetric organic loadings (VOL) at the ABR and UASB were 10.29 and 0.99 kg COD m-1d-1. Therefore, the ABR-UASB system was found to be a promising alternative for the swine wastewater treatment.


2014 ◽  
Vol 70 (2) ◽  
pp. 321-328 ◽  
Author(s):  
Thiago Emanuel Possmoser-Nascimento ◽  
Valéria Antônia Justino Rodrigues ◽  
Marcos von Sperling ◽  
Jean-Luc Vasel

Polishing ponds are natural systems used for the post-treatment of upflow anaerobic sludge blanket (UASB) effluents. They are designed as maturation ponds and their main goal is the removal of pathogens and nitrogen and an additional removal of residual organic matter from the UASB reactor. This study aimed to evaluate organic matter and suspended solids removal as well as sludge accumulation in two shallow polishing ponds in series treating sanitary effluent from a UASB reactor with a population equivalent of 200 inhabitants in Brazil, operating since 2002. For this evaluation, long-term monitoring of biochemical oxygen demand and total suspended solids and bathymetric surveys have been undertaken. The ponds showed an irregular distribution of total solids mass in the sludge layer of the two ponds, with mean accumulation values of 0.020 m3 person−1 year−1 and 0.004 m3 person−1 year−1 in Ponds 1 and 2, leading to around 40% and 8% of the liquid volume occupied by the sediments after 11 years of operation. The first pond showed better efficiency in relation to organic matter removal, although its contribution was limited, due to algal growth. No simple input–output mass balance of solids can be applied to the ponds due to algal growth in the liquid phase and sludge digestion in the sludge.


2019 ◽  
Vol 79 (7) ◽  
pp. 1231-1240 ◽  
Author(s):  
Gabriel Rodrigues Vasconcellos ◽  
Marcos von Sperling ◽  
Roberta Silva Ocampos

Abstract The objective of this work is to evaluate the performance of two horizontal subsurface flow constructed wetlands, one planted with cattail (Typha latifolia) and the other unplanted. The distinguishing feature of this study is that it spans a period of more than 10 years, from start-up to a final operation with heavy clogging and full overland flow. For most of the time, starting in June 2007, the system received municipal sewage previously treated in an upflow anaerobic sludge blanket (UASB) reactor, but for one specific period, the pre-treatment was comprised of the UASB reactor and a trickling filter in series. The two constructed wetlands worked in parallel, each serving approximately 50 p.e. and continuously receiving a flow around 7.5 m3 d−1 for most of the time. The beds had a length of 25 m and a width of 3 m and were filled with blast furnace slag. For most of this long operational period, performance was very good in terms of biochemical oxygen demand (BOD), chemical oxygen demand (COD) and total suspended solids (TSS), with median effluent concentrations of 19/18, 46/52 and 12/8, respectively (planted/unplanted units). Clogging was noticeable in the first years of operation, soon leading to overland flow. However, treatment performance was still successful, even when the system's hydraulics were strongly deteriorated. The type of pre-treatment and the applied loads influenced more the performance of the units than the period of operation itself, evidencing the robustness of the system.


2012 ◽  
Vol 65 (10) ◽  
pp. 1887-1894 ◽  
Author(s):  
V. Singh ◽  
A. K. Mittal

This study reports applicability of upflow anaerobic sludge blanket (UASB) process to treat the leachate from a municipal landfill located in Delhi. A laboratory scale reactor was operated at an organic loading rate of 3.00 kg chemical oxygen demand (COD)/m3 d corresponding to a hydraulic retention time (HRT) of 12 h for over 8 months. The effect of toxicity of leachate, and feed composition on the treatability of leachate was evaluated. Average COD of the leachate, during the study period varied between 8,880 and 66,420 mg/l. Toxicity of the leachate used during a period of 8 months varied from LC50 1.22 to 12.35 for 96 h. The removal efficiency of soluble COD ranged between 91 and 67% for fresh leachate and decreased drastically from 90 to 35% for old leachate having high toxicity. The efficiency varied from 81 to 65%. The reactor performed more efficiently for the treatment of fresh leachate (less toxic, LC50 11.64, 12.35, and 12.15 for 96 h) as compared with old leachate (more toxic, LC50 1.22 for 96 h). Toxicity of the leachate affected its treatment potential by the UASB.


1986 ◽  
Vol 18 (12) ◽  
pp. 99-108 ◽  
Author(s):  
Gatze Lettinga ◽  
Look Hulshoff Pol

Of the high rate anaerobic wastewater treatment systems the UASB (Upflow Anaerobic Sludge Blanket) reactor has found the widest application. Therefore the attention with respect to design, operation and economy will be focussed on this reactor type. In designing a UASB reactor specific attention is needed for the GSS (Gas-Solids Separator) device and the feed inlet system. For soluble wastewater generally no phase separation is required. Only for wastewaters high in suspended solids pre-acidification in a separate acidification reactor can be beneficial. Increasing attention is given to the development of modified UASB systems, such as a combination of a sludge bed reactor and an anaerobic filter. Other possible modified UASB systems may be found in a FS (Floating Settling) UASB reactor, the EGSB (Expanded Granular Sludge Bed) reactor and the UASB IC (Internal Circulation) reactor. As many factors are involved in the costs of a UASB reactor, only some rough data on reactor costs are presented.


Sign in / Sign up

Export Citation Format

Share Document