Degradation of service water systems is a major issue facing nuclear power plant owners, and many plants will require repair or replacement of existing carbon steel piping components. High Density Polyethylene pipe has been used in non-safety service water systems for over nine years and found to perform well, but it is not currently permitted in the ASME Section III Boiler and Pressure Vessel Code, Division 1 for use in nuclear safety-related systems. To assist in the implementation of High Density Polyethylene pipe in the ASME Boiler and Pressure Vessel Code, Section III, Division 1 for Safety Class 3 applications, EPRI initiated a High Density Polyethylene pipe and pipe material testing program. This test program includes tensile testing and fatigue testing of High Density Polyethylene piping and piping components and the development of slow crack growth data. To determine the material and engineering properties needed, extensive tensile testing of specimens cut from High Density Polyethylene pipe was conducted. The initial tensile test program was conducted on PE 3408 with cell classification 345464C and a second, not yet finalized, phase was added to test PE 4710 with cell classification 445474C. The data developed during the testing were used to establish ultimate strain, elastic moduli, yield stress and yield strain values for both new and aged materials. Because extruded HDPE properties vary in the hoop and axial directions and the properties are highly affected by temperature, specimens were cut in both the hoop and axial directions and were tested at temperatures ranging from 50° F to 180° F. This paper provides a description and overview of the PE 3408 cell class 345464C test program. In addition, an overview and summary of the test results for the PE 3408 cell class 345464C are provided.