scholarly journals Feasibility of using a high power CO{sub 2} laser as an alternative source to test high heat load x-ray optics

10.2172/87835 ◽  
1993 ◽  
Author(s):  
P.B. Fernandez
2021 ◽  
Vol 28 (6) ◽  
Author(s):  
Yuri Shvyd'ko ◽  
Sergey Terentyev ◽  
Vladimir Blank ◽  
Tomasz Kolodziej

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57Fe or 45Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.


1989 ◽  
Vol 2 (6) ◽  
pp. 12-12
Author(s):  
Elizabeth Stefanski
Keyword(s):  
X Ray ◽  

2016 ◽  
Vol 23 (5) ◽  
pp. 1118-1123 ◽  
Author(s):  
Stanislav Stoupin ◽  
Sergey Antipov ◽  
James E. Butler ◽  
Alexander V. Kolyadin ◽  
Andrey Katrusha

Fabrication and results of high-resolution X-ray topography characterization of diamond single-crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics are reported. The plates were fabricated by laser-cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. Wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking-curve topography. The variations of the rocking-curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.


1985 ◽  
Vol 54 (3) ◽  
pp. 371-384 ◽  
Author(s):  
Tsutomu Kuroda ◽  
Osamu Kaneko ◽  
Keiichi Sakurai ◽  
Yoshihide Oka ◽  
Masanao Shibui ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document