Stability Indicating RP-HPLC Method for Analysis of Ketoprofen in Bulk Drug and Eugenol Containing Nanoemulsion Gel (NEG) Formulation Using Response Surface Methodology

2014 ◽  
Vol 10 (2) ◽  
pp. 135-144 ◽  
Author(s):  
Manish Srivastava ◽  
Kanchan Kohli ◽  
Mushir Ali
Author(s):  
A. S. Sutar ◽  
C. S. Magdum

Design of Experiment assisted stability indicating RP-HPLC was developed and optimized using response surface methodology for determination of Tolvaptan.  Mobile phase was developed and optimized using Design of Experiment with response surface methodology. Acetonitrile and phosphate buffer with pH 5.5 (70:30% V/V) was optimized as mobile phase. The flow rate was maintained at 1ml/min. Stress studies were performed as per guidelines. Method was validated in accordance with regulatory requirements and results were within specified limits of regulatory guidelines. Tolvaptan was eluted at 3.24 min. It shows linearity from 2.5-15 µg/ml. Coefficient of correlation was 0.999, LOD and LOQ values were 1.0871 (µg/ml) and 3.2942 (µg/ml). Precision was determined with % RSD of 0.8669 and 0.9709%, mean percentage Recovery value was found to be 99.88 ±1.2. All stress degradation products are very well resolved from drug peak which indicate suitability indicating nature of the developed method. Design of Experiment technique can help in fast and economical optimization of mobile phase which inturn will save time for method development. The developed method is simple, accurate, sensitive which can be utilised as stability indicating method for identification of degradation products in routine analysis of the drug.


Author(s):  
Krutika Patel ◽  
Sudheer Kumar Verriboina ◽  
S.G. Vasantharaju

A simple, accurate, specific and stability-indicating RP-HPLC method was developed for simultaneous determination of chlorzoxazone, diclofenac sodium and paracetamol, using C18 Vydac Monomeric 120A (250 × 4.6mm, 5μ) at 40ºC. The mobile phase contains a mixture of 20mM potassium dihydrogen phosphate buffer (pH 6.2 adjusted with potassium hydroxide) and acetonitrile (30:70 v/v). The flow rate was 1ml/min and detection was carried out at 275nm using PDA detector. The retention time of paracetamol, chlorzoxazone and diclofenac sodium were 3.28mins, 13.27mins and 15.61mins respectively. The analytical curve was linear over a concentration range of 0.65- 6.5μg/ml for paracetamol, 1-10μg/ml for chlorzoxazone and 0.1-1μg/ml for diclofenac sodium. The drugs in bulk and tablet were subjected to acid and alkali hydrolysis, oxidation, thermal and photolytic degradation. This method can be successfully employed for simultaneous quantitative analysis of Chlorzoxazone, Diclofenac sodium and Paracetamol in bulk drug and tablet formulation.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


Author(s):  
GULAM MUSTAFA ◽  
ADNAN AZEEM ◽  
FARHAN J AHMAD ◽  
ZEENAT I KHAN ◽  
FAIYAZ SHAKEEL ◽  
...  

2021 ◽  
Vol 001 (02) ◽  
Author(s):  
Shalin Parikh ◽  
Jayant Dave ◽  
Jayendrakumar Patel

A simple, precise, accurate and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for determination of Ketoconazole in bulk drug and pharmaceutical dosage form. Isocratic RP-HPLC separation was achieved on Agilent C8 (150 mm ?4.6 mm, 5 µm particle size) with the mobile phase 0.3 % Triaethylamine in 20 mM potassium dihydrogen phosphate buffer pH adjusted to 4.0: Acetonitrile (68:32 % v/v) at a flow rate 1.0 ml/min. The retention time of Ketoconazole was 8.97 ± 0.50 min. The method was validated for specificity, linearity, precision, accuracy and robustness. The linear regression analysis data of calibration curve showed good linearity in concentration range 10-60 ?g/ml. The Intraday and Interday precision were 0.59-1.11 % and 0.26-1.73 % RSD respectively. The accuracy was found to be 98.11-99.26 %. The drug was subjected to the stress conditions like hydrolysis, oxidation, photolysis and dry heat. The proposed method is found to be specific with respect to degradation product formed after Acidic hydrolysis, Oxidation, Thermal and Photolytic degradation. The Ketoconazole was found to be stable under neutral hydrolytic, thermal and photolytic stress conditions. Acidic, thermal, photolytic stress conditions showed degradation. The proposed chromatographic method can be used for estimation of drug during stress testing & formal stability studies.


2022 ◽  
Vol 56 (1) ◽  
pp. 32-42
Author(s):  
Yik-Ling Chew ◽  
Hon-Kent Lee ◽  
Mei-Ann Khor ◽  
Kai-Bin Liew ◽  
Bontha Venkata Subrahmanya Lokesh ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document