A Novel Dynamic Weight Allocation Method for Assessing the Health Status of Remote Terminal Unit in Distribution Automation System Based on AHM and GRA

Author(s):  
Xinhao Bian ◽  
Jinrui Tang ◽  
Guoyan Chen ◽  
Wenxiong Mo ◽  
Hongbin Wang

Background: The Remote Terminal Units (RTUs) in the Distribution Automation System (DAS) are widely used in the field in recent years. It is lack of sample data in different operation status that makes the RTU maintenance improper. The weight allocation for the monitoring indicators in the health status evaluation needs to be identified efficiently and properly. Methods: A systematic health status assessment indicator system is constructed firstly. Then, a hybrid indicator weight allocation algorithm based on the Attribute Hierarchy Model (AHM) and grey relational degree (GRA) is proposed to identify the elementary item in the weight allocation under small sample condition. The final indicator weight would be dynamically adjusted according to the equilibrium coefficient, which is determined by the indicator condition parameter. Results: The simulation results show that the weight allocation can be effectively and reasonably adjusted according to the indicator value even under small sample condition. Conclusion: The expert experience and objective data laws are combined and used in our proposed dynamic weight allocation method. It can be used to assess the health status of RTU in the electrical power distribution network.

2015 ◽  
Vol 737 ◽  
pp. 214-219
Author(s):  
Peng Li ◽  
Kai Ding ◽  
Xin Shu ◽  
Gui Tong Guo

In this paper, based on the requirements of distribution automation system (DAS), the testing method of performance index of remote terminal unit is studied. The standardized test method and testing process with automatic test is discussed. The paper also brings forward a set of feasible testing and evaluation method on the distribution automation terminal device to ensure the safe and stable running of power distribution automation terminal.


2020 ◽  
Vol 5 (3) ◽  
pp. 53-57

Power Failure in the power system is mainly due to the overloading. The possible damage to the area is losing a power. The Arduino Uno based load control system is a device which automatically control overload on generator by controlling power and cut-off supply whenever consumers exceeds the amount of power supplied for peak period. This is achieved by Arduino Uno, which detect overload and simultaneously cut-off the supply for the period of generator overloading. In this paper system can be automated into two stages are monitoring function and controlling function. In Monitoring function it has to record the meter reading at different location in the system, for normal as well as overload condition which is required for system planning. Distribution Supervisory control and Data Acquisition System (DSCADA) performs some of these monitoring function and controlling function about switching operation that is controlling of relay circuit breaker. The function Impacts on Consumer as well as reliability. The research work to be aimed at developing local full scale distribution automation system which can be control from secondary distribution substation to the consumer end. Power distribution automation expected for the broad areas. The project aimed at uninterrupted power supply for loyal energy consumer by implementation of this the problem of interruption off power supply due to energy misusing consumer can be avoided. This system provides the reliable operation at consumer end.


2013 ◽  
Vol 415 ◽  
pp. 34-37
Author(s):  
Yu Li ◽  
Xiu Ying Tang ◽  
Xue Mei Leng ◽  
Yun Jiang Xu

Urbanization construction requirements of smart grid,and distribution automation is the foundation of smart grid.Because of its own characteristics of the rural power grid, the construction of distribution network is not the same of city construction. This paper from the rural development trend and its characteristics, analysis of the function of rural distribution automation system, and put forward the suitable for rural distribution automation mode from the aspects of main station system,substation,distribution terminal,communication system and feeder automation of several.


2013 ◽  
Vol 340 ◽  
pp. 1034-1038
Author(s):  
Yang Jia ◽  
Qiang Fu ◽  
Du Shi Ma ◽  
Ming Yang Zhu

Not only distribution automation system but the principle of the existing means of communication are studied systematically and distribution automation communication system model based on IP network is provided. Backbone network is set between master station in the control center and substation sub-station. Communication between electronic station and terminal connections rely on the branch network. Simulation experiment shows the test of data traffic and network delay of IP communications network. In the actual network environment the data refresh meet the application requirements. So the program on the improvement of distribution automation communication in this article is feasible.


2014 ◽  
Vol 552 ◽  
pp. 183-186
Author(s):  
Xue Song Zhou ◽  
Ya Fei Yuan ◽  
You Jie Ma

A distribution system consists of all sorts of power distribution equipment, communication system and control equipment. It works according to certain rules to meet the demand of users by the high quality of electric energy . Distribution Automation (DA) can realize the automation of system operation and management to provide customers with stable, reliable electricity and obtain maximum benefits .This paper generally introduces the concept, function, developing future of Distribution Automation System. Distribution Automation includes feeder automation, automatic distribution management and user automation, and this paper introduces the basic situation and problems of them. Finally, it is concluded that Distribution Automation is the inevitable trend of Distribution System,and will be gradually developing in the direction of smart distribution grid.


2021 ◽  
Vol 2121 (1) ◽  
pp. 012027
Author(s):  
Yinghua Song ◽  
Gang Wang

Abstract On the basis of analyzing and summarizing the current situation of the construction and use of distribution automation systems at home and abroad, according to the requirements of the use of distribution automation systems, a data two-way interactive distribution automation system architecture design is proposed. In response to the requirements for multi-source data collection in the distribution network, a distribution automation system architecture with partitioned collection and bidirectional data flow is proposed to improve the perception of distribution network equipment. Propose the self-recognition technology of power distribution system and terminal based on IEC61968 and IEC61850 model mapping to realize the fast access of power distribution terminal. Propose a grid integration modeling and global decision analysis method based on model splicing technology to realize multi-dimensional data fusion and analysis applications.


Sign in / Sign up

Export Citation Format

Share Document