terminal unit
Recently Published Documents


TOTAL DOCUMENTS

171
(FIVE YEARS 43)

H-INDEX

14
(FIVE YEARS 2)

Energies ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 7527
Author(s):  
Hyo-Jun Kim ◽  
Young-Hum Cho

This study reviewed the existing studies on the types of variable air volume (VAV) terminal units, control and operation methods, prediction models, and sensor calibration methods. As a result of analyzing the existing research trends on the system type, characteristics, and control method of VAV terminal units studies such as theoretical verification and energy simulation were conducted to improve the existing control methods, reset the set value using a mathematical model, and add a monitoring sensor for the application of control methods. The mathematical model used in the study of VAV terminal unit control methods was used to derive set values for minimum air volume, supply temperature, ventilation requirements, and indoor comfort. The mathematical model has a limitation in collecting input information for professional knowledge and model development, and development of a building environment prediction model using a black box model is being studied. The VAV terminal unit system uses a sensor to control the device, and when an error occurs in the sensor, indoor comfort problems and energy waste occur. To solve this problem, sensor calibration techniques have been developed using statistical models, mathematical models, and Bayesian statistical models. The possibility of developing a method for calibrating the variable air volume terminal unit sensor using the prediction model was confirmed. In conclusion, the VAV terminal unit system is one of the most energy efficient systems. The energy saving potential of current VAV systems can still be improved through control methods, the use of predictive models, and sensor calibration methods.


MIND Journal ◽  
2021 ◽  
Vol 6 (1) ◽  
pp. 57-72
Author(s):  
RIFKI FIKRANDANI NUGRAHA ◽  
TEGUH ARFIANTO

AbstrakPada penelitian ini dilakukan evaluasi proteksi gangguan tegangan lebih pada generator Unit 3 PLTP Kamojang yang diproteksi oleh sebuah relay tegangan lebih menggunakan simulasi pada software ETAP. Simulasi dilakukan untuk melihat bagaimana cara kerja relay tegangan lebih dan bentuk tegangan lebih yang terjadi pada terminal generator. Skenario simulasi yang digunakan yaitu melakukan pelepasan beban 50,7 MW dan relay yang digunakan dalam simulasi berfungsi untuk menyalakan alarm saat terjadi tegangan lebih. Hasil simulasi memperlihatkan bahwa pada saat terjadi pelepasan beban, relay tegangan lebih menyalakan alarm 1,1 detik setelah membaca tegangan naik hingga 13 kV atau sebesar 110% dari tegangan nominalnya, kemudian tegangan terminal generator naik hingga 13,2 kV hingga kembali ke kondisi steady state 5 detik setelah terjadi kenaikkan tegangan. Hasil simulasi tersebut menunjukkan bahwa relay tegangan lebih yang terpasang pada terminal generator Unit 3 bekerja sesuai dengan fungsinya yaitu untuk memberikan alarm ketika tegangan lebih terjadi.Kata kunci: pelepasan beban, proteksi generator, relay proteksi, simulasi generator, tegangan lebihAbstractThis study evaluates overvoltage fault protection on the generator Unit 3 PLTP Kamojang which is protected by an overvoltage relay using simulation on ETAP software. Simulations are carried out to see how the overvoltage relay works and the form of overvoltage that occurs at the generator terminals. The scenario used is by do a load shedding of 53,3MW, the relay used in this simulation has a function to turn on the alarm when overvoltage occurs. The results show that when a load shedding occurs, the overvoltage relay turns on the alarm 1,1 seconds after reading the voltage up to 13 kV or 110% of the nominal voltage, then the generator terminal voltage rises to 13.2 kV until it returns to steady state 5 seconds after the voltage increase. The simulation results indicate that the overvoltage relay installed at the generator terminal Unit 3 works according to its function, namely to provide a warning when an overvoltage occurs.Keywords: generator protection, load shedding, overvoltage, protection relay, generator simulation


Author(s):  
Xuecen Zhang ◽  
Qiang Liu ◽  
Yi Tang ◽  
Guofeng Liu ◽  
Xin Ning ◽  
...  

2021 ◽  
Vol 5 (1) ◽  
pp. 26-29
Author(s):  
Indra Hardian Mulyadi ◽  
Rahmi Mahdaliza ◽  
Aditya Gautama Darmoyono ◽  
Senanjung Prayoga ◽  
Kamarudin Kamarudin

Modul akuisisi data dengan menggunakan Modbus Remote Terminal Unit (RTU) telah banyak digunakan secara komersial di industri. Namun sayangnya, harga peralatan tersebut tergolong mahal. Protokol komunikasi Modbus RTU ini cukup kompleks untuk dibuat oleh pengguna awam, seperti siswa sekolah menengah vokasi dan mahasiswa. Dengan latar belakang tersebut, penelitian ini bertujuan untuk membuat modul komunikasi Modbus RTU over RS485 yang berbasiskan Arduino sehingga harga pembuatannya menjadi murah dan dapat menjadi sarana pembelajaran di sekolah menengah maupun universitas. Modul yang dibuat ini terdiri atas dua input analog dan dua input/output digital. Sinyal analog yang masuk dikondisikan terlebih dahulu dengan menggunakan signal conditioner sebelum diproses lebih lanjut oleh mikrokontroler. Hasil pengujian menggunakan Modbus Analyzer menunjukkan bahwa komunikasi Modbus RTU over RS485 pada modul yang telah dibuat ini berjalan dengan baik.


Sign in / Sign up

Export Citation Format

Share Document