Explaining Sources of Biosolids Odors at Wastewater Treatment Plant (WWTP) by Utilizing Real-Time Odor Monitoring System and Statistical Models

2014 ◽  
Vol 2014 (2) ◽  
pp. 1-18
Author(s):  
Ampun Janpengpen ◽  
Tortrakul Yomnak ◽  
Mark Ramirez ◽  
Christopher Peot ◽  
Tawiwat Veeraklaew
1998 ◽  
Vol 37 (1) ◽  
pp. 347-354 ◽  
Author(s):  
Ole Mark ◽  
Claes Hernebring ◽  
Peter Magnusson

The present paper describes the Helsingborg Pilot Project, a part of the Technology Validation Project: “Integrated Wastewater” (TVP) under the EU Innovation Programme. The objective of the Helsingborg Pilot Project is to demonstrate implementation of integrated tools for the simulation of the sewer system and the wastewater treatment plant (WWTP), both in the analyses and the operational phases. The paper deals with the programme for investigating the impact of real time control (RTC) on the performance of the sewer system and wastewater treatment plant. As the project still is in a very early phase, this paper focuses on the modelling of the transport of pollutants and the evaluation of the effect on the sediment deposition pattern from the implementation of real time control in the sewer system.


2016 ◽  
Vol 35 (3) ◽  
pp. 702-716 ◽  
Author(s):  
Jenna E. Cavallin ◽  
Kathleen M. Jensen ◽  
Michael D. Kahl ◽  
Daniel L. Villeneuve ◽  
Kathy E. Lee ◽  
...  

2019 ◽  
Vol 80 (8) ◽  
pp. 1421-1429 ◽  
Author(s):  
Maria Rosa di Cicco ◽  
Antonio Spagnuolo ◽  
Antonio Masiello ◽  
Carmela Vetromile ◽  
Mariano Nappa ◽  
...  

Abstract The wastewater sector accounts for 25% of the global energy demand in the water sector. Since this consumption is expected to increase in the forthcoming years, energy optimization strategies are needed. A truly effective planning of energy improvement measures requires a detailed knowledge of a system, which can only be achieved through energy audit and real-time monitoring. In order to improve the identification of critical issues related to the use of energy resources within a wastewater treatment plant (WWTP), the paper shows the results of a monitoring campaign performed on a large WWTP in southern Italy. Data obtained for the audit cover a 4-year timeframe (2014–2017). Energy–environmental performance has been evaluated through the benchmarking of: system variables, specific consumptions, and operational indicators. Moreover, by using a real-time data measurement and acquisition system it has been possible to evaluate the real performance of the most energy-intensive apparatus of the plant (a turbo-blower), over a period of 8 months. The main results indicate that (a) the plant is mainly affected by a massive capture of infiltrations, working in conditions close to the maximum hydraulic capacity, (b) real-time energy measurements are necessary to accurately characterize plant consumptions and adequately assess their critical aspects.


2006 ◽  
Vol 53 (4-5) ◽  
pp. 523-532 ◽  
Author(s):  
A. Morikawa ◽  
I. Hirashiki ◽  
S. Furukawa

A coliforms monitoring system in treated effluent of a wastewater treatment plant has been developed. In order to achieve rapid monitoring within 1 hour, an enzymatic fluorescence method without a culturing process was introduced to this system. It converts the increase rate of fluorescence intensity as enzymatic activity into the number of coliforms instead of converting fluorescence intensity itself. A flow injection analysis is used in this system for automatic measurement. Moreover, it is equipped with the pre-filtering unit to remove the interfering substances in the suspended solids causing deterioration in measurement precision. The good relationship (correlation coefficient of 0.90) between the obtained values using this system and the analysed values using the conventional direct counting method was observed in a test at an existing wastewater treatment plant.


1994 ◽  
Vol 30 (2) ◽  
pp. 149-156 ◽  
Author(s):  
Andrea G. Capodaglio

Wastewater treatment plant automation and real-time control have become important topics of research and development. Real-time control is nowadays considered a desirable goal for medium- to large-sized utilities for attaining better treatment efficiencies and improved compliance with discharge permit limitations. For an efficient implementation, real-time control must be supported by adequate modelling methodologies that take into full account the dynamic properties of the treatment system. This paper evaluates the requirements of such applications and the properties of available modelling approaches. Some applications examples are discussed.


2009 ◽  
Vol 76 (3) ◽  
pp. 715-723 ◽  
Author(s):  
Theng-Theng Fong ◽  
Mantha S. Phanikumar ◽  
Irene Xagoraraki ◽  
Joan B. Rose

ABSTRACT Enteric viruses are important pathogens found in contaminated surface waters and have previously been detected in waters of the Great Lakes. Human adenoviruses were monitored because of their high prevalence and persistence in aquatic environments. In this study, we quantified adenoviruses in wastewater, surface water, and combined sewer overflows (CSOs) by real-time PCR. Between August 2005 and August 2006, adenovirus concentrations in raw sewage, primary-treated effluent, secondary-treated effluent, and chlorinated effluent from a wastewater treatment plant in Michigan were examined. CSO samples (n = 6) were collected from a CSO retention basin in Grand Rapids, MI. Adenoviruses were detected in 100% of wastewater and CSO discharge samples. Average adenovirus DNA concentrations in sewage and CSOs were 1.15 × 106 viruses/liter and 5.35 × 105 viruses/liter, respectively. Adenovirus removal was <2 log10 (99%) at the wastewater treatment plant. Adenovirus type 41 (60% of clones), type 12 (29%), type 40 (3%), type 2 (3%), and type 3 (3%) were isolated from raw sewage and primary effluents (n = 28). Six of 20 surface water samples from recreational parks at the lower Grand River showed virus concentrations above the real-time PCR detection limit (average, 7.8 × 103 viruses/liter). This research demonstrates that wastewater effluents and wastewater-impacted surface waters in the lower Grand River in Michigan contain high levels of viruses and may not be suitable for full-body recreational activities. High concentrations of adenovirus in these waters may be due to inefficient removal during wastewater treatment and to the high persistence of these viruses in the environment.


Sign in / Sign up

Export Citation Format

Share Document