scholarly journals Digital Cardiovascular Biomarker Responses to Transcutaneous Cervical Vagus Nerve Stimulation: State-Space Modeling, Prediction, and Simulation

10.2196/20488 ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. e20488 ◽  
Author(s):  
Asim H Gazi ◽  
Nil Z Gurel ◽  
Kristine L S Richardson ◽  
Matthew T Wittbrodt ◽  
Amit J Shah ◽  
...  

Background Transcutaneous cervical vagus nerve stimulation (tcVNS) is a promising alternative to implantable stimulation of the vagus nerve. With demonstrated potential in myriad applications, ranging from systemic inflammation reduction to traumatic stress attenuation, closed-loop tcVNS during periods of risk could improve treatment efficacy and reduce ineffective delivery. However, achieving this requires a deeper understanding of biomarker changes over time. Objective The aim of the present study was to reveal the dynamics of relevant cardiovascular biomarkers, extracted from wearable sensing modalities, in response to tcVNS. Methods Twenty-four human subjects were recruited for a randomized double-blind clinical trial, for whom electrocardiography and photoplethysmography were used to measure heart rate and photoplethysmogram amplitude responses to tcVNS, respectively. Modeling these responses in state-space, we (1) compared the biomarkers in terms of their predictability and active vs sham differentiation, (2) studied the latency between stimulation onset and measurable effects, and (3) visualized the true and model-simulated biomarker responses to tcVNS. Results The models accurately predicted future heart rate and photoplethysmogram amplitude values with root mean square errors of approximately one-fifth the standard deviations of the data. Moreover, (1) the photoplethysmogram amplitude showed superior predictability (P=.03) and active vs sham separation compared to heart rate; (2) a consistent delay of greater than 5 seconds was found between tcVNS onset and cardiovascular effects; and (3) dynamic characteristics differentiated responses to tcVNS from the sham stimulation. Conclusions This work furthers the state of the art by modeling pertinent biomarker responses to tcVNS. Through subsequent analysis, we discovered three key findings with implications related to (1) wearable sensing devices for bioelectronic medicine, (2) the dominant mechanism of action for tcVNS-induced effects on cardiovascular physiology, and (3) the existence of dynamic biomarker signatures that can be leveraged when titrating therapy in closed loop. Trial Registration ClinicalTrials.gov NCT02992899; https://clinicaltrials.gov/ct2/show/NCT02992899 International Registered Report Identifier (IRRID) RR2-10.1016/j.brs.2019.08.002

2020 ◽  
Author(s):  
Asim H Gazi ◽  
Nil Z Gurel ◽  
Kristine L S Richardson ◽  
Matthew T Wittbrodt ◽  
Amit J Shah ◽  
...  

BACKGROUND Transcutaneous cervical vagus nerve stimulation (tcVNS) is a promising alternative to implantable stimulation of the vagus nerve. With demonstrated potential in myriad applications, ranging from systemic inflammation reduction to traumatic stress attenuation, closed-loop tcVNS during periods of risk could improve treatment efficacy and reduce ineffective delivery. However, achieving this requires a deeper understanding of biomarker changes over time. OBJECTIVE The aim of the present study was to reveal the dynamics of relevant cardiovascular biomarkers, extracted from wearable sensing modalities, in response to tcVNS. METHODS Twenty-four human subjects were recruited for a randomized double-blind clinical trial, for whom electrocardiography and photoplethysmography were used to measure heart rate and photoplethysmogram amplitude responses to tcVNS, respectively. Modeling these responses in state-space, we (1) compared the biomarkers in terms of their predictability and active vs sham differentiation, (2) studied the latency between stimulation onset and measurable effects, and (3) visualized the true and model-simulated biomarker responses to tcVNS. RESULTS The models accurately predicted future heart rate and photoplethysmogram amplitude values with root mean square errors of approximately one-fifth the standard deviations of the data. Moreover, (1) the photoplethysmogram amplitude showed superior predictability (<i>P</i>=.03) and active vs sham separation compared to heart rate; (2) a consistent delay of greater than 5 seconds was found between tcVNS onset and cardiovascular effects; and (3) dynamic characteristics differentiated responses to tcVNS from the sham stimulation. CONCLUSIONS This work furthers the state of the art by modeling pertinent biomarker responses to tcVNS. Through subsequent analysis, we discovered three key findings with implications related to (1) wearable sensing devices for bioelectronic medicine, (2) the dominant mechanism of action for tcVNS-induced effects on cardiovascular physiology, and (3) the existence of dynamic biomarker signatures that can be leveraged when titrating therapy in closed loop. CLINICALTRIAL ClinicalTrials.gov NCT02992899; https://clinicaltrials.gov/ct2/show/NCT02992899 INTERNATIONAL REGISTERED REPORT RR2-10.1016/j.brs.2019.08.002


2019 ◽  
Vol 12 (2) ◽  
pp. e13 ◽  
Author(s):  
Nil Z. Gurel ◽  
Hewon H.J. Jung ◽  
Allison Hankus ◽  
Stacy L. Ladd ◽  
Mobashir H. Shandhi ◽  
...  

PLoS ONE ◽  
2017 ◽  
Vol 12 (10) ◽  
pp. e0186068 ◽  
Author(s):  
Hector M. Romero-Ugalde ◽  
Virginie Le Rolle ◽  
Jean-Luc Bonnet ◽  
Christine Henry ◽  
Alain Bel ◽  
...  

2014 ◽  
Vol 7 (6) ◽  
pp. 914-916 ◽  
Author(s):  
Didier Clarençon ◽  
Sonia Pellissier ◽  
Valérie Sinniger ◽  
Astrid Kibleur ◽  
Dominique Hoffman ◽  
...  

Seizure ◽  
2008 ◽  
Vol 17 (5) ◽  
pp. 469-472 ◽  
Author(s):  
Stephan A. Koenig ◽  
Elke Longin ◽  
Nellie Bell ◽  
Julia Reinhard ◽  
Thorsten Gerstner

Author(s):  
Jozsef Constantin Széles ◽  
Stefan Kampusch ◽  
Florian Thürk ◽  
Christian Clodi ◽  
Norbert Thomas ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document