scholarly journals Comparison of Solvers Performance for Load Flow Analysis

2019 ◽  
Vol 3 (1) ◽  
pp. 26 ◽  
Author(s):  
Vishnu Sidaarth Suresh

Load flow studies are carried out in order to find a steady state solution of a power system network. It is done to continuously monitor the system and decide upon future expansion of the system. The parameters of the system monitored are voltage magnitude, voltage angle, active and reactive power. This paper presents techniques used in order to obtain such parameters for a standard IEEE – 30 bus and IEEE-57 bus network and makes a comparison into the differences with regard to computational time and effectiveness of each solver

Author(s):  
Hayatul Harifin ◽  
Novalio Daratha ◽  
M. Khairul Amri Rosa

AbstractLoad flow analysis is a study to plan and determine the amount of power in an electric power system. During its development, industry requires a large amount of electric power and uses electrical equipment as a means of production. The benefits of an electric load flow analysis are to find out the amount of power in the electric power system whether it still meets predetermined limits, and to find out the amount of voltage at each point, and to obtain initial conditions for the new system planning. Load flow analysis begins calculating the active power and reactive power at each node (bus) installed, loading on the channel or conductor, the load flow calculation will be assisted using the Julia program. From the results of calculations using the Julia program, the voltage at each point with the smallest stress is obtained, namely the 10th point of 209.89 - j10.34V for phase A, -107.39 - j186.87V for phase B, -108.12 + j178,51V for phase CKey Words: Drop Voltage, Julia, Load Flow


Author(s):  
GUNEET KOUR ◽  
G.S. BRAR ◽  
JASWANTI JASWANTI

With increase in load, any transmission, distribution and generating model suffers from disturbances. These disturbances effect the overall stability of the system. Criterias like voltage profile, power flows, losses tell us about the state of the system under study. Load flow analysis of the system under study is capable of providing the insight of the system. The Emergence of FACTS device is really a step forward for the flexible control or Power System Operations. FACTS is the name given to the application of the power electronics devices to control power flows and other quantities in the power system. But when it comes to implementation stage, optimizing the location becomes a great concern because of the high cost involved with FACTS devices especially converter like SVC, STATCOM etc. Static Var Compensator (SVC) is a power quality device, which employs power electronics to control the reactive power flow of the system where it is connected. It is able to provide fast-acting reactive power compensation on electrical systems. SVC is one of the methods and can be applied to obtain a system with least losses, increased power flow and healthy voltage profile. Number, location and size of SVC are the main concerns and they can be optimized to a great extent by Genetic Algorithm (GA) or any other method. Use of SVC in a system has shown considerable increase in voltage profile and power flows while decrease in losses.


2011 ◽  
Vol 383-390 ◽  
pp. 2346-2349
Author(s):  
Jie Luo ◽  
Wen Hui Wu

Power flow analysis plays a significant role in both design and operational stage. The purpose of any load flow analysis is to compute accurate steady state voltages and voltage angles of all buses in a network, the real and reactive power flows into every line and transformer, under the assumption of known generation and load. This paper focus on fast decoupled flow, a practical power system has been used as an example to introduce its application in actual calculation, what’s more, develops a fast decoupled load flow calculation program for n-node system by taking advantage of MATLAB. A visual GUI interface is also established with MATLAB. In addition, the paper proposes a new simple power system data format, different from the IEEE standard one. The correctness and simplicity of the proposed format is verified through IEEE-5bus,-9bus,-11bus,-39bus systems.


Author(s):  
Shenghu Li

The induction generators (IGs) are basic to wind energy conversion. They produce the active power and consume the reactive power, with the voltage characteristics fragile compared with that of the synchronous generators and doubly-fed IGs. In the stressed system states, they may intensify var imbalance, yielding undesirable operation of zone 3 impedance relays.In this paper, the operation characteristics of the zone 3 relays in the wind power systems is studied. With the theoretical and load flow analysis, it is proved that the equivalent impedance of the IGs lies in the 2nd quadrature, possibly seen as the backward faults by the mho relays, i.e. the apparent impedance enters into the protection region from the left side. The undesirable operation may be caused by more wind power, larger load, less var compensation, and larger torque angle.


2012 ◽  
Vol 433-440 ◽  
pp. 7208-7212
Author(s):  
Ya Min Su Hlaing ◽  
Ze Ya Aung

This thesis implements power flow application, Newton-Raphson method. The Newton-Raphson method is mainly employed in the solution of power flow problems. The network of Myanma electric power system is used as the reference case. The system network contains 90 buses and 106 brunches. The weak points are found in the network by using Newton-Raphson method. Bus 16, 17, 85 and 86 have the most weak bus voltages. The medium transmission line between bus 87 and bus 17 is compensated by using MATLAB program software. The transmission line is compensated with shunt reactors, series and shunt capacitors to improve transient and steady-state stability, more economical loading, and minimum voltage dip on load buses and to supply the requisite reactive power to maintain the receiving end voltage at a satisfactory level. The system performance is tested under steady-state condition. This paper investigates and improves the steady–state operation of Myanma Power System Network.


Author(s):  
Ajith M ◽  
Dr. R. Rajeswari

Power-flow studies are of great significance in planning and designing the future expansion of power systems as well as in determining the best operation of existing systems. Technologies such as renewables and power electronics are aiding in power conversion and control, thus making the power system massive, complex, and dynamic. HVDC is being preferred due to limitations in HVAC such as reactive power loss, stability, current carrying capacity, operation and control. The HVDC system is being used for bulk power transmission over long distances with minimum losses using overhead transmission lines or submarine cable crossings. Recent years have witnessed an unprecedented growth in the number of the HVDC projects. Due to the vast size and inaccessibility of transmission systems, real time testing can prove to be difficult. Thus analyzing power system stability through computer modeling and simulation proves to be a viable solution in this case. The motivation of this project is to construct and analyze the load flow and short circuit behavior in an IEEE 14 bus power system with DC link using MATLAB software. This involves determining the parameters for converter transformer, rectifier, inverter and DC cable for modelling the DC link. The line chosen for incorporation of DC link is a weak bus. This project gives the results of load flow and along with comparison of reactive power flow, system losses, voltage in an AC and an AC-DC system.