scholarly journals Pengembangan Perangkat Lunak Untuk Analisis Aliran Beban Tiga Fasa Pada Jaringan Tegangan Rendah Dengan Metode Newton Berbasis Calculus Wirtinger

Author(s):  
Hayatul Harifin ◽  
Novalio Daratha ◽  
M. Khairul Amri Rosa

AbstractLoad flow analysis is a study to plan and determine the amount of power in an electric power system. During its development, industry requires a large amount of electric power and uses electrical equipment as a means of production. The benefits of an electric load flow analysis are to find out the amount of power in the electric power system whether it still meets predetermined limits, and to find out the amount of voltage at each point, and to obtain initial conditions for the new system planning. Load flow analysis begins calculating the active power and reactive power at each node (bus) installed, loading on the channel or conductor, the load flow calculation will be assisted using the Julia program. From the results of calculations using the Julia program, the voltage at each point with the smallest stress is obtained, namely the 10th point of 209.89 - j10.34V for phase A, -107.39 - j186.87V for phase B, -108.12 + j178,51V for phase CKey Words: Drop Voltage, Julia, Load Flow

2011 ◽  
Vol 383-390 ◽  
pp. 2346-2349
Author(s):  
Jie Luo ◽  
Wen Hui Wu

Power flow analysis plays a significant role in both design and operational stage. The purpose of any load flow analysis is to compute accurate steady state voltages and voltage angles of all buses in a network, the real and reactive power flows into every line and transformer, under the assumption of known generation and load. This paper focus on fast decoupled flow, a practical power system has been used as an example to introduce its application in actual calculation, what’s more, develops a fast decoupled load flow calculation program for n-node system by taking advantage of MATLAB. A visual GUI interface is also established with MATLAB. In addition, the paper proposes a new simple power system data format, different from the IEEE standard one. The correctness and simplicity of the proposed format is verified through IEEE-5bus,-9bus,-11bus,-39bus systems.


2021 ◽  
Vol 5 (2) ◽  
pp. 80-87
Author(s):  
Muhammad Ruswandi Djalal ◽  
Makmur Saini ◽  
A.M Shiddiq Yunus

Power flow analysis in an electric power system is an analysis that reveals the performance of an electric power system and the flow of power (active and reactive) for certain conditions when the system is working. The analysis was carried out using the ETAP 16.00 software, the method used was the newton rapshon by taking a case study of normal conditions. From the results of the study, it can be seen that the power flow that occurs in each channel of the 150 kV system in the South Sulawesi system. The amount of active power (MW) that occurs during normal conditions based on the simulation is 1730.87 MW, where the active power is the largest, which is 171 MW from BUS15_TLASA to BUS13_SGMNSA. For the voltage data, there is a slight comparison of the voltage during the simulation compared to the PLN data.


2019 ◽  
Vol 3 (1) ◽  
pp. 26 ◽  
Author(s):  
Vishnu Sidaarth Suresh

Load flow studies are carried out in order to find a steady state solution of a power system network. It is done to continuously monitor the system and decide upon future expansion of the system. The parameters of the system monitored are voltage magnitude, voltage angle, active and reactive power. This paper presents techniques used in order to obtain such parameters for a standard IEEE – 30 bus and IEEE-57 bus network and makes a comparison into the differences with regard to computational time and effectiveness of each solver


Author(s):  
Ahmad Fateh Mohamad Nor ◽  
Marizan Sulaiman ◽  
Aida Fazliana Abdul Kadir ◽  
Rosli Omar

Voltage instability analysis in electric power system is one of the most important factors in order to maintain the equilibrium of the power system. A power system is said to be unstable if the system is not able to maintain the voltage at all buses in the system remain unchanged after the system is being subjected to a disturbance.The research work presented in this paper is about the analysis of voltage instability of electric power system by using voltage stability margin (VSM), load real power (P) margin, reactive power (Q) margin, reactive power-voltage (QV) and real power-voltage (PV) modal analysis. IEEE 30-bus system has been chosen as the power system. The load flow analysis are simulated by using Power World Simulator software version 16. Both QV and PV modal analysis were done by using MATLAB application software.


Author(s):  
Fadhel Putra Winarta ◽  
Yoli Andi Rozzi

The study of electric power flow analysis (Load Flow) is intended to obtain information about the flow of power or voltage in an electric power system network. This information is needed to evaluate the performance of the power system. Electrical power flow problems include calculating the flow and system voltage at certain terminals or buses. The benefits of this power flow study are to find out the voltage at each node in the system, to find out whether all the equipment meets the specified limits to deliver the desired power, and to obtain the original conditions in the new system planning. This study is divided into two: the analysis of data when the conditions have not been added wind turbine and after the addition of 300 kW wind turbine with software power station ETAP software 12.6.0 and the Newton-Raphson method will be used in analyzing the power flow of the electric power system. Based on the results of the tests, it is found that the overall value of losses for power flow before the addition of DG is 0.031 MW and 0.037 Mvar, for the voltage drop with the lowest percentage, namely on bus 10 with a percentage of 96.45 for the 0.4 kV system and the 20 kV system on bus 19 with a percentage of 99.03, the largest% PF load was in lump 1 with 98.64 and the smallest% PF was in lump7 with a value of 84.92. The short circuit data value on the 20 kV bus system at Andalas University before the addition of DG with 3-phase disturbances averaged 13.354 A, 1-phase disturbances averaged 3.521 A, 2-phase disturbances averaged 11.719 A and 2 ground phases of 12.842 A Whereas for the value of power flow after the addition of DG in the form of the wind turbine of 300 kW the overall value of losses is 0.032 MW and 0.042 MvarAR, for the voltage drop with the percentage for voltage drop with the lowest percentage is bus 10 with a percentage of 96.63 for system 0, 4 kV and a 20 kV system on bus 14 with a percentage of 98.1, the largest% PF load is in lump 1 with 98.64 and the smallest% PF is in lump7 with a value of 84.92. The short circuit data value on the 20 kV bus system at Andalas University after the addition of DG with 3 phase disturbances has an average value of 13.354 A, 1 phase disturbance averages 3.523 A, 2 phase disturbances average 11.737 A and 2 phases ground is 12.059 A For the source in this system, after the addition of DG, there was a change in the% PF of the PLN grid, namely 79.53 and the wind turbine -83%.


Author(s):  
GUNEET KOUR ◽  
G.S. BRAR ◽  
JASWANTI JASWANTI

With increase in load, any transmission, distribution and generating model suffers from disturbances. These disturbances effect the overall stability of the system. Criterias like voltage profile, power flows, losses tell us about the state of the system under study. Load flow analysis of the system under study is capable of providing the insight of the system. The Emergence of FACTS device is really a step forward for the flexible control or Power System Operations. FACTS is the name given to the application of the power electronics devices to control power flows and other quantities in the power system. But when it comes to implementation stage, optimizing the location becomes a great concern because of the high cost involved with FACTS devices especially converter like SVC, STATCOM etc. Static Var Compensator (SVC) is a power quality device, which employs power electronics to control the reactive power flow of the system where it is connected. It is able to provide fast-acting reactive power compensation on electrical systems. SVC is one of the methods and can be applied to obtain a system with least losses, increased power flow and healthy voltage profile. Number, location and size of SVC are the main concerns and they can be optimized to a great extent by Genetic Algorithm (GA) or any other method. Use of SVC in a system has shown considerable increase in voltage profile and power flows while decrease in losses.


Author(s):  
Rudy Gianto ◽  
Ade Elbani

As they are more efficient in extracting wind energy, variable speed wind power plants (WPPs) are currently replacing the fixed speed WPPs. One possible way to achieve a variable speed WPP is by using a squirrel cage induction generator (SCIG) with full-scale power electronic converter (PEC). In fact, as its cost is relatively lower, the application of SCIG-based variable speed WPP is gaining popularity nowadays. To be able to perform proper analyses (including the load flow analysis) of an electric power system, valid and accurate modeling of the system components is very important. This paper discusses the steady state model of SCIG-based variable speed WPP in power factor control mode for a load flow analysis of an electric power distribution system. The model was developed based on formulas that calculate the turbine mechanical power input and WPP electrical power output. Integration of the proposed model in load flow analysis is also discussed and presented in this paper.


Author(s):  
Robi Kurniawan ◽  
Ardiansyah Nasution ◽  
Arnawan Hasibuan ◽  
Muzamir Isa ◽  
Muskan Gard ◽  
...  

Distributed Generation (DG) is a small capacity generator located in the electricity distribution system and is usually placed on buses that are connected directly to the load. Placement of distributed generation is one of the technical efforts to reduce voltage drop and power losses in the system. In addition, load flow analysis is a study to plan and determine the amount of power in an electric power system. The results of power losses after adding distributed generation were the best in the fifth experiment on bus 149, where the system experienced a total loss of active power (P) previously of 720,822 kW, to 682,939 kW and total loss of reactive power (Q) previously of 530.02 kVar, to 405.835 kVar. From the results of the calculation of the power flow using ETAP software (Electrical Transient Analyzer Program). So, it can be concluded that the electrical network system can be said to be good. The results obtained are the more DG (wind turbine generator) that is input into the bus it will reduce the voltage drop that occurs. After simulating the overall voltage drop, it still meets the standards according to the results of the Text Report on ETAP.


Author(s):  
Shenghu Li

The induction generators (IGs) are basic to wind energy conversion. They produce the active power and consume the reactive power, with the voltage characteristics fragile compared with that of the synchronous generators and doubly-fed IGs. In the stressed system states, they may intensify var imbalance, yielding undesirable operation of zone 3 impedance relays.In this paper, the operation characteristics of the zone 3 relays in the wind power systems is studied. With the theoretical and load flow analysis, it is proved that the equivalent impedance of the IGs lies in the 2nd quadrature, possibly seen as the backward faults by the mho relays, i.e. the apparent impedance enters into the protection region from the left side. The undesirable operation may be caused by more wind power, larger load, less var compensation, and larger torque angle.