scholarly journals Seasonal performance assessment of a dual source heat pump system for heating, cooling and domestic hot water production

Author(s):  
Antonio Cazorla-Marín ◽  
Carla Montagud ◽  
José M. Corberán ◽  
Javier Marchante-Avellaneda
2021 ◽  
Vol 2095 (1) ◽  
pp. 012077
Author(s):  
Xiaoming Zhang ◽  
Qiang Wang ◽  
Qiujin Sun ◽  
Mingyu Shao

Abstract There have been few practical applications of solar coupled groundwater source heat pump (GWHP) systems in large public buildings, and data on this technology are scarce. A solar coupled GWHP system was investigated in this study. The system uses an underground water source heat pump system for heating in winter, cooling in summer, and providing part of the domestic hot water, and it also uses a solar energy system to prepare domestic hot water. These two types of energy are complementary. The system was tested throughout the cooling season. This experiment ran from May 10, 2021, to September 10, 2021. The results show that the system can guarantee the indoor design temperature and the supply of domestic hot water. The solar water heating system operated for 1233 min in the summer; hot water (2334 m3) was prepared. During the summer, the average energy efficiency ratio of the GWHP unit was approximately 4.88. The energy efficiency ratio of the entire system was approximately 3.34. Such projects can play a key role in demonstrating this type of system.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 2020 ◽  
Author(s):  
Jeffrey Spitler ◽  
Signhild Gehlin

When the new student center at Stockholm University in Sweden was completed in the fall of 2013 it was thoroughly instrumented. The 6300 m2 four-story building with offices, a restaurant, study lounges, and meeting rooms was designed to be energy efficient with a planned total energy use of 25 kWh/m2/year. Space heating and hot water are provided by a ground source heat pump (GSHP) system consisting of five 40 kW off-the-shelf water-to-water heat pumps connected to 20 boreholes in hard rock, drilled to a depth of 200 m. Space cooling is provided by direct cooling from the boreholes. This paper uses measured performance data from Studenthuset to calculate the actual thermal performance of the GSHP system during one of its early years of operation. Monthly system coefficients-of-performance and coefficients-of-performance for both heating and cooling operation are presented. In the first months of operation, several problems were corrected, leading to improved performance. This paper provides long-term measured system performance data from a recently installed GSHP system, shows how the various system components affect the performance, presents an uncertainty analysis, and describes how some unanticipated consequences of the design may be ameliorated. Seasonal performance factors (SPF) are evaluated based on the SEPEMO (“SEasonal PErformance factor and MOnitoring for heat pump systems”) boundary schema. For heating (“H”), SPFs of 3.7 ± 0.2 and 2.7 ± 0.13 were obtained for boundaries H2 and H3, respectively. For cooling (“C”), a C2 SPF of 27 ± 5 was obtained. Results are compared to measured performance data from 55 GSHP systems serving commercial buildings that are reported in the literature.


2012 ◽  
Vol 517 ◽  
pp. 875-880
Author(s):  
Xiao Heng Zhang ◽  
Guang Cai Gong ◽  
Jian Yong Zhou

Compound condensing heat pump combines the advantages of heat pump technology and condensing heat recovery technology. It takes full account of the common infrastructure in the cooling and heat source system and greatly increases equipment utilization ratio. It also recycles condensing heat to produce sanitary hot water efficiently while ensuring cooling and heating of heat pump to achieve the same effect. The distinctive technical features of the compound condensation / evaporation of four functional heat pump ensure its efficient and reliable operation. This heat pump system runs in several models throughout the year,which include the refrigeration mode, refrigeration&domestic hot water mode, domestic hot water mode and heating mode. The performance in refrigeration mode and refrigeration&domestic hot water mode is studied by a designed experiment is done and the an explicit analysis is made. By comparing the results of simlation and experiment,an agreement can be shown clearly. Therefore,the final conclusion is drawn:the performance of compound condensation / evaporation of four functional heat pump is improved over the traditional heat pump.It is worthy to further promote for the sake of energy saving.


Sign in / Sign up

Export Citation Format

Share Document