scholarly journals Reducing the Electrogram Review Burden Imposed by Insertable Cardiac Monitors

Author(s):  
Roy S. Gardner ◽  
Fabio Quartieri ◽  
Tim Betts ◽  
Muhammad Afzal ◽  
Harish Manyam ◽  
...  

Background: Insertable cardiac monitors (ICMs) are essential for ambulatory arrhythmia diagnosis. However, definitive diagnoses still require time-consuming, manual adjudication of electrograms (EGMs). Objective: To evaluate the clinical impact of selecting only key EGMs for review. Methods: Retrospective analyses of randomly selected Abbott Confirm Rx devices with ≥90 days of remote transmission history was performed, with each EGM adjudicated as true or false positive (TP, FP). For each device, up to 3 “key EGMs” per arrhythmia type per day were prioritized for review based on ventricular rate and episode duration. The reduction in EGMs and TP days (patient-days with at least 1 TP EGM), and any diagnostic delay (from the first TP), were calculated vs. reviewing all EGMs. Results: In 1,000 ICMs over a median duration of 8.1 months, at least one atrial fibrillation (AF), tachycardia, bradycardia, or pause EGM was transmitted by 424, 343, 190, and 325 devices, respectively, with a total of 95716 EGMs. Approximately 90% of episodes were contributed by 25% of patients. Key EGM selection reduced EGM review burden by 43%, 66%, 77%, and 50% (55% overall), while reducing TP days by 0.8%, 2.1%, 0.2%, and 0.0%, respectively. Despite reviewing fewer EGMs, 99% of devices with a TP EGM were ultimately diagnosed on the same day vs. reviewing all EGMs. Conclusions: Key EGM selection reduced the EGM review substantially with no delay-to-diagnosis in 99% of patients exhibiting true arrhythmias. Implementing these rules in the Abbott patient care network may accelerate clinical workflow without compromising diagnostic timelines.

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
RS Gardner ◽  
F Quartieri ◽  
TR Betts ◽  
M Afzal ◽  
H Manyam ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The insertable cardiac monitor (ICM) is an essential tool for the ambulatory diagnosis of arrhythmias. However, definitive diagnoses still rely on time-consuming, manual adjudication of electrograms (EGMs) transmitted to the patient care network. This EGM review burden may be minimized by automatically selecting a subset of EGMs for fast review without delaying the diagnosis. Purpose Develop EGM selection strategies to reduce the EGM review burden without delaying diagnoses. Methods A retrospective analysis of 1,000 randomly selected Abbott Confirm Rx devices with 90+ days of remote transmission history was performed, regardless of transmission frequency, and all EGMs were adjudicated as either true or false positive (TP, FP). Up to 3 EGMs per day per arrhythmia type were prioritized for review based on ventricular rate and episode duration, with rules specific to each arrhythmia type: atrial fibrillation (AF), tachycardia, bradycardia, and pause. The resulting reduction in EGM review burden and TP days (patient-days with at least 1 TP EGM), as well as any diagnostic delay from the first transmitted TP, were calculated relative to reviewing all transmitted EGMs. Results In this population and transmission period, at least one AF, tachycardia, bradycardia, and pause EGM was transmitted by 424, 343, 190, and 325 unique devices, respectively, with a total of 35,723, 12,239, 19,752, and 28,002 EGMs, and a total of 6,163, 1,572, 1,438, and 646 TP days. For these patients with ≥1 EGM, the median [IQR] EGM transmission rate was 2.6 [0.7, 11.6], 1.1 [0.4, 4.7], 2.1 [0.6, 10.7], and 3.4 [0.6, 29.9] EGMs/patient/month, respectively. The optimal EGM selection strategy reduced this EGM review burden by 43%, 67%, 76%, and 50%, while only missing 3.4%, 2.2%, 0.3%, and 0.2% of TP days, respectively. Ultimately, 97%, 99%, 99%, and 99% of devices with a TP AF, tachycardia, bradycardia, or pause EGM exhibited no diagnostic delay vs. reviewing all transmitted EGMs. Conclusion EGM prioritization rules for selecting up to 3 episodes/day significantly reduced EGM burden across all patients, not just "frequent fliers," with no delay-to-diagnosis in >97% of patients who exhibited a true arrhythmia. Implementing these rules on the patient care network may improve clinical workflow and ICM patient management. Abstract Figure.


2016 ◽  
Vol 10 (1) ◽  
pp. 26
Author(s):  
Pragnesh Parikh ◽  
◽  
KL Venkatachalam ◽  

Atrial fibrillation (AF) is the most common arrhythmia noted in clinical practice and its incidence and prevalence are on the rise. The single most important intervention is the evaluation and treatment of stroke risk. Once the risk for stroke has been minimized, controlling the ventricular rate and treating symptoms become relevant. In this review article, we emphasize the importance of confirming and treating the appropriate arrhythmia and correlating symptoms with rhythm changes. Furthermore, we evaluate some of the risk factors for AF that independently result in symptoms, underlining the need to treat these risk factors as part of symptom control. We then discuss existing and novel approaches to rate control in AF and briefly cover rhythm control methods.


Circulation ◽  
1996 ◽  
Vol 94 (5) ◽  
pp. 1023-1026 ◽  
Author(s):  
S. Adam Strickberger ◽  
Raul Weiss ◽  
Emile G. Daoud ◽  
Rajiva Goyal ◽  
Frank Bogun ◽  
...  

Circulation ◽  
1996 ◽  
Vol 93 (2) ◽  
pp. 277-283 ◽  
Author(s):  
Gerhard Kreiner ◽  
Gottfried Heinz ◽  
Peter Siostrzonek ◽  
Heinz David Gössinger

2021 ◽  
Vol 10 (1) ◽  
pp. e001270
Author(s):  
Jonathan James Hyett Bray ◽  
Elin Fflur Lloyd ◽  
Firdaus Adenwalla ◽  
Sarah Kelly ◽  
Kathie Wareham ◽  
...  

BackgroundCommunity management of atrial fibrillation (AF) often requires the use of electrocardiographic (ECG) investigation. Patients discharged following treatment of AF with fast ventricular response (fast AF) can require numerous ECGs to monitor rate and/or rhythm control. Single-lead ECGs have been proposed as a more convenient and relatively accurate alternative to 12-lead ECGs for rate/rhythm management and also diagnosis of AF. We aimed to examine the feasibility of using the AliveCor single-lead ECG monitor for diagnosis and monitoring of AF in the community setting.MethodsDuring the course of 6 months, this evaluation of a clinical service improvement pathway used the AliveCor in management of patients requiring (1) follow-up ECGs for AF with previously documented rapid ventricular rate or (2) ECG confirmation of rhythm where AF was suspected. Twelve AliveCor devices provided to the acute community medical team were used to produce 30 s ECG rhythm strips (iECG) that were electronically sent to an overreading physician.ResultsSeventy-four patients (mean age 82 years) were managed on this pathway. (1) The AliveCor was successfully used to monitor the follow-up of 37 patients with fast AF, acquiring a combined total of 113 iECGs (median 1.5 ±3.75 per patient). None of these patients required a subsequent 12-lead ECG and this approach saved an estimate of up to £134.49 per patient. (2) Of 53 patients with abnormal pulses, the system helped identify 8 cases of new onset AF and 19 cases of previously known AF that had reverted from sinus back into AF.ConclusionsWe have demonstrated that the AliveCor system is a feasible, cost-effective, time-efficient and potentially safer alternative to serial 12-lead ECGs for community monitoring and diagnosis of AF.


Sign in / Sign up

Export Citation Format

Share Document