scholarly journals Effects of different bleaching methods on shear bond strengths of orthodontic brackets

2012 ◽  
Vol 83 (4) ◽  
pp. 686-690 ◽  
Author(s):  
Ahmet Yalcin Gungor ◽  
Erhan Ozcan ◽  
Huseyin Alkis ◽  
Hakan Turkkahraman

ABSTRACT Objective: To evaluate the effects of different bleaching methods on the shear bond strength (SBS) of orthodontic brackets. Materials and Methods: Forty-five freshly extracted premolars were randomly divided into three groups (n  =  15 per group). In group I, bleaching was performed with the office bleaching method. In group II, bleaching was performed with the home bleaching method. Group III served as the control. Orthodontic brackets were bonded with a light cure composite resin and cured with an LED light. After bonding, the SBS of the brackets were tested with a Universal testing machine. Results: Analysis of variance indicated a significant difference between groups (P < .001). The highest values for SBS were measured in group III (20.99 ± 2.32 MPa). The SBS was significantly lower in groups I and II than in group III (P < .001). The lowest values for SBS were measured in group II (6.42 ± 0.81 MPa). SBS was significantly higher in group I than in group II (P < .001). Conclusions: Both of the bleaching methods significantly affected the SBS of orthodontic brackets on human enamel. Bleaching with the home bleaching method affected SBS more adversely than did bleaching with the office bleaching method.

2007 ◽  
Vol 77 (6) ◽  
pp. 1096-1100 ◽  
Author(s):  
Hakan Türkkahraman ◽  
Necdet Adanir

Abstract Objective: To evaluate the effects of potassium nitrate and oxalate desensitizer agents on shear bond strengths of orthodontic brackets. Materials and Methods: Forty-five extracted human premolar teeth were randomly assigned to three groups of 15 each. UltraEZ potassium nitrate desensitizer was applied on teeth in the first group, while BisBlock oxalate desensitizer was applied on teeth in the second group. The third group served as a control. Orthodontic brackets were bonded with a light cure composite resin and cured with a halogen light. After bonding, the shear bond strength of the brackets was tested with a universal testing machine. Results: The highest shear bond strengths were measured in Group III. The shear bond strength in Groups I and II was significantly lower than in Group III (P < .001). Significant difference was also found between Group I and Group II (P < .01). Conclusions: Orthodontic brackets bonded to enamel treated with potassium nitrate and oxalate desensitizers showed significantly lower bond strengths than did brackets bonded to untreated enamel.


2020 ◽  
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Sanjay Prasad Gupta

Abstract Background: Recycling the old or debonded bracket is one possible alternative to the replacement with new bracket. The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength.Methods: One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022”) brackets, (Leone co., Sesto, Florentine, Florence, Italy) were bonded on buccal surface of all samples with light cured adhesive primer Orthosol (Enlight, Ormco corp., USA) using LED curing unit for 10 seconds. Group I was assigned as control and the brackets of Group II, Group III and Group IV were subjected to recycling by flaming (Gas microtorch: RS Pro, Nozzle, MT 790) ,flaming with sandblasting (Bio-Art sandblaster; Rua Teotônio Vilela, Brazil) and flaming with ultrasonic cleaning (Ultrasonic cleaning unit ,Confident dental equipments Ltd, India) respectively. The recycled brackets were rebonded and final debonding of all brackets was done with universal testing machine (AG-IC/100 KN, Shimadzu, Japan) at a crosshead speed of 0.5mm/min and shear bond strength (MPa) was determined. The adhesive remnant index was evaluated by stereomicroscope at 10X magnification (Olympus corp., Japan). Results: The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa), Group IV (5.97 ± 0.66 MPa) and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another (p < 0.001). The Chi-square showed statistically significant differences in the adhesive remnant index of the 4 groups (p < 0.001). Conclusions: Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided borderline value for clinical use while flaming alone led to significantly lower value.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Dr. Sanjay Prasad Gupta

Aim. The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength. Methods. One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022″) brackets were bonded on the buccal surface of all samples with light cured adhesive primers using an LED curing unit for 10 seconds. Group I was assigned as control, and the brackets of Group II, Group III, and Group IV were subjected to recycling by flaming, flaming with sandblasting, and flaming with ultrasonic cleaning, respectively. The recycled brackets were rebonded, and final debonding of all brackets was performed using a universal testing machine at a crosshead speed of 0.5 mm/min and shear bond strength was determined. Data were analyzed with descriptive statistics, ANOVA, and post hoc tests. The adhesive remnant index was evaluated using a stereomicroscope at 10X magnification. Results. The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa) and Group IV (5.97 ± 0.66 MPa), and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey’s post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another ( p < 0.001 ). Conclusions. Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided a borderline value for clinical use, and flaming alone led to a significantly lower value.


2021 ◽  
Author(s):  
Purna Prasad Khanal ◽  
Basanta Kumar Shrestha ◽  
Rajiv Yadav ◽  
Sanjay Prasad Gupta

Abstract Aim: The aim of this study was to evaluate and compare the effect of different methods of recycling stainless steel orthodontic brackets on shear bond strength.Methods: One hundred twenty human premolars extracted for orthodontic purpose were randomly divided into four groups. Standard MBT (0.022”) brackets were bonded on buccal surface of all samples with light cured adhesive primer using LED curing unit for 10 seconds. Group-I was assigned as control and the brackets of Group-II, Group-III and Group-IV were subjected to recycling by flaming, flaming with sandblasting and flaming with ultrasonic cleaning respectively. The recycled brackets were rebonded and final debonding of all brackets was done with universal testing machine at a crosshead speed of 0.5mm/min and shear bond strength was determined. Data were analyzed with descriptive statistics, ANOVA and post hoc test. The adhesive remnant index was evaluated by stereomicroscope at 10X magnification.Results: The highest shear bond strength was obtained with Group I (10.35 ± 0.46 MPa), followed by Group III (9.36 ± 0.55 MPa), Group IV (5.97 ± 0.66 MPa) and the least value was obtained with Group II (4.30 ± 0.55 Mpa). Significant differences among the groups were detected by analysis of variance. Tukey post hoc multiple comparison test showed that the shear bond strength of each group was significantly different from one another (p < 0.001). Conclusions: Shear bond strength of new brackets was significantly higher than that of the recycled brackets. Among recycled brackets, flaming with sandblasting provided adequate shear bond strength, flaming with ultrasonic cleaning provided borderline value for clinical use while flaming alone led to significantly lower value.


2009 ◽  
Vol 03 (03) ◽  
pp. 173-177 ◽  
Author(s):  
Ahmet Yalcin Gungor ◽  
Hakan Turkkahraman ◽  
Necdet Adanir ◽  
Huseyin Alkis

ABSTRACTObjectives: To evaluate the effects fluorosis and self etching primers (SEP) on shear bond strengths (SBS) of orthodontic brackets.Methods: A total of 48 (24 fluorosed and 24 non-fluorosed) non-carious freshly extracted human permanent premolar teeth were used in this study. Fluorosed teeth were selected according to the modified Thylstrup and Fejerskov index (TFI), which is based on the clinical changes in fluorosed teeth. Fluorosed and non-fluorosed teeth were randomly assigned to 4 groups of 12 each. In groups I (non-fluorosed teeth) and II (fluorosed teeth), standard etching protocol was used and brackets were bonded with Light Bond. In groups III (non-fluorosed teeth) and IV (fluorosed teeth), Transbond Plus SEP was used and brackets were bonded with Transbond XT Light Cure Adhesive. All specimens were cured with a halogen light. After bonding, SBS of the brackets were tested with Universal testing machine. After debonding, all teeth and brackets in the test groups were examined under 10x magnifications. Any adhesive remained after debonding was assessed and scored according to the modified Adhesive Remnant Index (ARI).Results: ANOVA indicated a significant difference between groups (P<.001). SBS in group II (Light Bond+Fluorosis) were significantly lower than other groups. ARI scores of the groups were also significantly different (P<.001). There was a greater frequency of ARI scores of 1,2 and 3 in group II (Light Bond+Fluorosis).Conclusions: When standard etching protocol was used enamel fluorosis significantly decreased the bond strength of orthodontic brackets. Satisfactory bond strengths were obtained when SEP was used for bonding brackets to the fluorosed teeth. (Eur J Dent 2009;3:173-177)


2014 ◽  
Vol 15 (6) ◽  
pp. 688-692 ◽  
Author(s):  
Sukumaran Anil ◽  
Farouk Ahmed Hussein ◽  
Mohammed Ibrahim Hashem ◽  
Elna P Chalisserry

ABSTRACT Objective The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Subjects and methods Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. Results No statistically significant difference was found in bond strengths’ values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. Conclusion The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength. How to cite this article Hussein FA, Hashem MI, Chalisserry EP, Anil S. The Impact of Chlorhexidine Mouth Rinse on the Bond Strength of Polycarbonate Orthodontic Brackets. J Contemp Dent Pract 2014;15(6):688-692.


2016 ◽  
Vol 10 (01) ◽  
pp. 040-045 ◽  
Author(s):  
Hakan Colak ◽  
Ertugrul Ercan ◽  
Mehmet Mustafa Hamidi

ABSTRACT Objectives: Bulk-fill composite materials are being developed for preparation depths of up to 4 mm in an effort to simplify and improve the placement of direct composite posterior restorations. The aim of our study was to compare shear-bond strength of bulk-fill and conventional posterior composite resins. Materials and Methods: In this study, 60 caries free extracted human molars were used and sectioned parallel to occlusal surface to expose midcoronal dentin. The specimens were randomly divided into four groups. Total-etch dentine bonding system (Adper Scotchbond 1XT, 3M ESPE) was applied to dentin surface in all the groups to reduce variability in results. Then, dentine surfaces covered by following materials. Group I: SonicFill Bulk-Fill, Group II: Tetric EvoCeram (TBF), Group III: Herculite XRV Ultra, and Group IV: TBF Bulk-Fill, 2 mm × 3 mm cylindrical restorations were prepared by using application apparatus. Shear bond testing was measured by using a universal testing machine. Kruskal–Wallis and Mann–Whitney U-tests were performed to evaluate the data. Results: The highest value was observed in Group III (14.42 ± 4.34) and the lowest value was observed in Group IV (11.16 ± 2.76) and there is a statistically significant difference between these groups (P = 0.046). However, there is no statistically significant difference between the values of other groups. In this study, Group III was showed higher strength values. Conclusion: There is a need for future studies about long-term bond strength and clinical success of these adhesive and bulk-fill systems.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Anahita Jablonski-Momeni ◽  
R. Nothelfer ◽  
M. Morawietz ◽  
A. Kiesow ◽  
H. Korbmacher-Steiner

Abstract Enamel demineralisation can occur as a side effect during orthodontic treatment with fixed appliances. This study aimed to evaluate the efficacy of the self-assembling peptide P11-4 for remineralisation combined with fluorides, compared to application of fluoride varnish alone. De- and remineralisation was assessed by Quantitative light-induced fluorescence (QLF). Orthodontic brackets were bonded on 108 human enamel samples and white spot lesions were created. The samples were allocated randomly into three groups: Group I received no treatment, group II had a single application of fluoride varnish (22,600 ppm), and group III was treated with P11-4 following a single application of fluoride varnish. Quantitative light-induced fluorescence (QLF) measurements were performed at baseline, after demineralisation and after storage in remineralisation solution for 7 and 30 days. Non-parametric tests (Kruskal–Wallis test and Friedman test) were used for further analysis. After demineralisation, all samples showed a median ΔF -9.38% ± 2.79. After 30 days median ΔF values were as followed: group I = -9.04% ± 2.51, group II = -7.89 ± 2.07, group III = -6.08% ± 2.79). The median ΔF values differed significantly between all groups at all investigation times (p < 0.00001). Application of P11-4 with fluoride varnish was superior to the use of fluorides alone for remineralisation of enamel adjacent to brackets.


2020 ◽  
Author(s):  
Sana Lala ◽  
Thuraya Lazkani

Abstract Background:In restorative dentistry we usually use Sandwich Technique for posterior restorations where GIC is placed below and a resin composite is placed over it. The bonding strength between these two materials are low. We are looking for the best adhesive system to put it in between. We think that the self-etching bond will give the best bonding strength between them whereas total etch will give lower bonding strength than self-etching system. Methods:ION-Z GIC was bonded to resin composite by using two different bonding agents. The thirty specimens used were prepared by using acrylic blocks with holes in each hole to retain the ION-Z GIC. The specimens were randomly divided into three groups:Group I: Control group.Group II: Total-etch adhesive was applied and cured over ION-Z GIC.Group III: Self-etch adhesive was applied and cured.The composite resin placed over the ION-Z GIC and cured. The shear bond strength was measured by shearing of the bonded specimens on Universal Testing Machine (Model 114) using speed of 0.1mm / minute. The reading was tabulated and subjected to statistical analysis using ANOVA and Tukey's test.Results:The test showed statistically significant difference between Group III and Group I and between Group III and Group II. Group III had the highest shear bonding strength.Conclusion:Self-etch adhesive agent produces have better shear bond strength to ION-Z than total-etch adhesive and to the group without any bonding agent.


2015 ◽  
Vol 09 (02) ◽  
pp. 224-227 ◽  
Author(s):  
Shenbagakuttalam Anand ◽  
Ambrose Vedamanickam Rajesh Ebenezar ◽  
Nirupa Anand ◽  
Kothandaraman Rajkumar ◽  
Sekar Mahalaxmi ◽  
...  

ABSTRACT Objectives: To comparatively assess the micro shear bond strength (MSBS) of dentin bonded surface pre-treated zirconia ceramics. Materials and Methods: Zirconia blocks were sectioned into 50 cubical blocks. The blocks were further categorized into five groups (n = 10 each). Group I: No treatment was performed on zirconia samples; Group II: The zirconia samples were sand-blasted; Group III: Group II + etched with 9.8% of hydrofluoric (HF) acid for 60 s; Group IV: The sandblasted zirconia samples were selectively infiltrated with low fusing porcelain; and Group V: Group IV + etched using 9.8% HF acid gel. The zirconia specimens were then bonded to dentin samples, and the samples were tested for MSBS evaluation using universal testing machine. Results: The MSBS of all the four experimental groups shows greater value than group I. Among the experimental groups, group V and group IV do not show any statistical significant difference, whereas the mean MSBS of groups IV and V were statistically greater than group III and group II. However, groups I, II, and III do not show any statistical significant difference in mean MSBS values between them. Conclusion: Selective infiltration etching of zirconia ceramics provides the highest bond strength with resin cement.


Sign in / Sign up

Export Citation Format

Share Document