scholarly journals Blood pressure monitoring during liver transplantation: the method of measurement does matter

Author(s):  
M. L. Katin ◽  
A. M. Dzyadz`ko ◽  
M. Yu. Gurova ◽  
O. O. Rummo

Introduction. Accurate blood pressure (BP) measurements are the mainstay for the efficient management of abrupt changes of hemodynamics and perfusion during orthotopic liver transplantation (OLT).Material and methods. The prospective study included 39 patients. We compared the BP values measured in the femoral and radial arteries during the different phases of the OLT.Results. The central systolic arterial pressure (SAP) and mean arterial pressure (MAP) measured invasive in the femoral artery were significantly higher than those measured in the peripheral artery during the anhepatic phase (95.1±10.6 vs. 84.5±9.9 mm Hg, and 66±8.8 vs. 59.7±7.1 mm Hg, respectively), after 5 minutes of reperfusion (91.1±17.3 vs. 78.5±18.4 mm Hg, and 63.9±13.1 vs. 57.7±13.6 mm Hg, respectively), and after 15 minutes of reperfusion (102.2±16.8 vs. 88.1±14.4 mm Hg, and 67.7±10.7 vs. 62.5±10.4 mm Hg, respectively). We found a strong correlation between the differences of SAP and MAP and the dose of norepinephrine administered during the anhepatic phase (r=0.76 and r=0.77 for SAP and MAP, respectively), and after 5 minutes of reperfusion (r=0.71 and r=0.52 for SAP and MAP, respectively). The difference between central and peripheral BPs after 15 minutes of reperfusion mainly depended on the changes in the potassium concentration (r=0.55 for SAP and MAP) and base deficiency (r=0.73 and r=0.82 for SAP and MAP, respectively).Conclusion. Thus, it was proved that the invasive measurement of BP in the femoral artery is a more accurate method compared with that in the radial artery as it is less exposed to high doses of vasopressors and variations in the acid-base state during OLT. 

2017 ◽  
Vol 41 (S1) ◽  
pp. S373-S373
Author(s):  
M. Angelats ◽  
A. Leila ◽  
C. David ◽  
P. Laia ◽  
M. Laura ◽  
...  

IntroductionThe electroconvulsive therapy (ECT) is an effective treatment used for several psychiatric disorders. However, there are multiple enigmas about the mechanisms of action and factors that improve its results. Some frequent questions are if the anesthetic drug makes a difference in the time of convulsion and blood pressure.AimsOur principal aim is to describe the utilization of anesthetic drugs among the patients that are being treated with ECT in hospital del Mar. We also want to know the differences in the time of convulsion and systolic arterial pressure for every anesthetic drug (propofol, thiopental and etomidate).Material and methodsWe have used the database of ECT in hospital del Mar. It contains information like age, principal diagnosis, medical background and pharmacological treatment at the moment of starting ECTs; it also contains information of each individual ECT session as basal, 2 and 5 minutes arterial pressure; the anesthetic drug used, and convulsion duration.We made an analysis of general conditions of the population, the differences of convulsion time and arterial pressure between the three anesthetic drugs.ResultsPropofol was used in 1140 sessions, thiopental in 61 sessions and etomidate in 54 sessions. The differences in the means of convulsion times between propofol and etomidate are statistically significant (“P” value < 0.05). Etomidate or thiopental increases the difference of arterial pressure more than propofol.ConclusionsFurther research about the factors that improve convulsion duration and minimize adverse effects on blood pressure is needed.Disclosure of interestThe authors have not supplied their declaration of competing interest.


Author(s):  
V. M. Tikhonenko ◽  
V. V. Pivovarov ◽  
A. Y. Kormilitsyn ◽  
G. К. Zaitsev

Objective. To assess the clinical signifcance of auscultatory gap (AG) found by the 24-hour ambulatory blood pressure monitoring (ABPM) using the Korotkoff’s sounds (KS) and its potential causes.Design and methods. 24-hour ABPM was performed in 60 patients (mean age 51,3 years, range 22–85 years), including 24 women and 36 men. In 24 patients, hypertension was diagnosed. In total, 2333 blood pressure (BP) measurements without “noise contamination” were selected for subsequent analysis (38,9 measurements per patient; from 28 to 73 measurements). The simultaneous recording of electrocardiogram (ECG), brachial cuff pressure, and KS phonograms on the right hand, as well as continuous recording of non-invasive BP curve in the left fnger using the volume clamp technique were performed in 10 patients with AG.Results. Based on the 24-hour ABPM, AG was shown in 43 of 60 subjects (71,7%). The AG was found to be associated with a decreased amplitude of fluctuations of the cuff pressure; upon its termination, the amplitude recovered. The above synchrony of changes in KS and amplitude of pressure fluctuations was found in all 124 cases which demonstrated AG during BP measurement. We assume that AG is a true variation of BP rather than a feature of KS, as the fluctuation amplitude depends on the ratio of BP and cuff pressure but does not depend on the KS phase. To test the hypothesis, the cuff pressure and KS were compared to the continuously monitored arterial pressure. When the systolic arterial pressure exceeded the cuff pressure, the KS appeared. Later on, the BP fluctuations led to a decrease in systolic BP; the arterial pressure did not reach the cuff pressure and, therefore, KS were not recorded. Subsequent decrease in the cuff pressure led to re-appearance of KS.Conclusions. The auscultative gap phenomenon is associated with true (mostly respiratory) variations of systolic BP rather than with features of KS in individual patients. The initial and repetitive KS occur at certain systolic BP levels depensing on the BP respiratory fluctuations and may indirectly indicate the amplitude of fluctuations.


e-CliniC ◽  
2019 ◽  
Vol 7 (2) ◽  
Author(s):  
Cerelia E. C. Sugeng ◽  
Emma Sy. Moeis ◽  
Glady I. Rambert

Abstract: Hypertension and anxiety are among the group of the most common chronic disease worldwide, and according to numerous studies they are oftentimes associated each other. Patients suffered from chronic illnesses, such as hypertension, may have negative emotion that increases the risk of mental disorders, most commonly anxiety disorder. This study was aimed to assess the difference of anxiety degree between uncontrolled and controlled hypertensive patients. This was an observational analytical study with a cross-sectional design. Subjects were divided into two groups: controlled and uncontrolled hypertensive patients. Measurement of blood pressure parameter was performed by using office blood pressure monitoring. Anxiety parameter was classified based on the scoring of the Generalized Anxiety Disorder Scale (GAD-7). Data were analyzed by using the Mann-Whitney test. Subjects consisted of 60 hypertensive patients (35 males and 25 females), aged 30-70 years (mean 56.48 years). There were 35 controlled hypertension patients and 22 uncontrolled hypertensive patients. The results showed that the difference in anxiety degree based on GAD-7 between controlled hypertensive and uncontrolled hypertensive groups obtained a p-value of 0.000. In conclusion, there was a significant difference in anxiety degree between uncontrolled and controlled hypertensive patients. Screening for anxiety among hypertensive patients is a simple and cost-effective tool that may improve outcomes.Keywords: anxiety, uncontrolled hypertension, controlled hypertension Abstrak: Hipertensi dan ansietas merupakan kelompok penyakit kronik yang paling umum di seluruh dunia. Berdasarkan banyak penelitian kedua penyakit ini saling berhubungan satu sama lain. Penyandang hipertensi mungkin memiliki emosi negatif yang meningkatkan risiko terjadinya gangguan mental berupa ansietas. Ansietas dan dukungan sosial rendah akan menghambat proses penyembuhan terutama dalam mengontrol tekanan darah. Penelitian ini bertujuan untuk menge-tahui apakah terdapat perbedaan derajat ansietas antara penyandang hipertensi belum terkontrol dengan hipertensi terkontrol. Jenis penelitian ialah analitik observasional dengan desain potong lintang. Subyek penelitian dibagi menjadi dua kelompok, yaitu kelompok penyandang hipertensi belum terkontrol dan hipertensi terkontrol. Pengukuran parameter tekanan darah dilakukan dengan menggunakan alat Oscillometric digital dengan cara Office Blood Pressure Monitoring (OBPM). Parameter ansietas diklasifikasikan berdasarkan skala Generalized Anxiety Disorder Scale (GAD-7). Adanya perbedaan derajat ansietas antara kedua kelompok dinilai dengan uji Mann-Whitney. Subyek penelitian terdiri dari 60 penyandang hipertensi (35 laki-laki dan 25 perempuan) berusia 30-70 tahun (rerata 56,48 tahun). Terdapat 25 penyandang hipertensi yang belum terkontrol dan 35 penyandang hipertensi terkontrol. Hasil penelitian menunjukkan bahwa terdapat perbedaan derajat ansietas berdasarkan GAD-7 antara kedua kelompok (p=0,000). Simpulan penelitian ini ialah terdapat perbedaan bermakna dalam derajat ansietas antara penyandang hipertensi yang belum terkontrol dengan yang terkontrol. Skrining ansietas pada penyandang hipertensi merupakan modalitas penting dalam penatalaksanaan penyandang hipertensi.Kata kunci: ansietas, hipertensi belum terkontrol, hipertensi terkontrol


Author(s):  
V.S. Pasko

The aim of the study was to determine the peculiarities of ABPM indices in middle-aged and elderly hypertensive patients depending on the daily BP profile. Material and methods. Indices of ambulatory blood pressure monitoring were identified in 57 middle-aged patients (45-59 years) (group I) and 43 elderly patients (60-74 years) (group II), who underwent two-week in-patient treatment. The control group consisted of 15 patients for every of the surveyed categories (group III - middle-aged and group IV – elderly respectively) matched with basic by age and gender. Results. We have shown that one of the factors that determines the change in hemodynamics in patients with essential hypertension is age, with the age patients experience the decrease in diastolic blood pressure with steadily increased systolic blood pressure, that should be considered in the prescription of antihypertensive treatment. With age, a gradual increase in systolic blood pressure is associated with the increased aortic stiffness, partially with the increase in collagen and the decrease in elastic fibrils and the formation of isolated systolic hypertension. Thus, it is proved that in the formation of isolated hypertension the growth of pulse blood pressure for more than 60 mm Hg is unfavorable in a development of cerebrovascular events. Pulse arterial blood pressure was stronger risk factor than systolic blood pressure and diastolic blood pressure or average arterial pressure in the elderly. Recently, taking into account age characteristics, all three indices were recognized as comparable predictors at the age of 50-59 years as the transitional period, and at the age of 60-79 years diastolic blood pressure adversely affecting the cardiovascular risk, increased pulse blood pressure prognostically above the level of systolic arterial pressure.


SLEEP ◽  
2020 ◽  
Vol 43 (Supplement_1) ◽  
pp. A399-A400
Author(s):  
R H Roth ◽  
H Bonner ◽  
J Logan ◽  
M Baruch ◽  
D Calhoun ◽  
...  

Abstract Introduction Abnormal nocturnal blood pressure(BP) such as non-dipping or nocturnal hypertension(reverse-dipping) represents a potent marker for cardiovascular risks. Standard cuff-based ambulatory nocturnal BP measurement yields limited data points potentially resulting in imprecise results, especially compared to continuously recorded BP. We hypothesized nocturnal BP based on periodic measurement would be different from true average beat-to-beat based BP. Methods We prospectively enrolled patients undergoing clinically indicated in-lab polysomnography, both CPAP and non-CPAP studies, for sleep apnea evaluation. Nocturnal BP was continuously monitored beat-to-beat by a noninvasive Caretaker™ device, which uses the Pulse Decomposition Analysis(PDA) algorithm. We compared BP recorded at 30-minute intervals with average BP continuously recorded over 30 minutes, both recorded by Caretaker™. We also looked at the differences between recording spot and continuous BP from an awake or sleeping state and BP variability(SD) based on continuously recorded BP. Using first 30 min as a reference, we determined dipping status (dipping: 10-20% reduction, level: 0-10% reduction, riser: any increase) by the two methods. Results A total of 18 patients were recruited(male:11, mean age:52.2). Among a total of 261 periodic BP measurements, 60 (30.0%) were obtained while awake. Mean nocturnal SBP by periodic BP measurement was higher compared with beat-to-beat-derived average BP(135.6mmHg[24.2] vs. 131.5[20.3], p&lt;0.0001). The difference between the two methods remained similar when continuous BP was derived from sleep vs. awake period(4.5mmHg[3.1] vs. 7.7[9.9], p=0.202). BP variability was more pronounced during awake compared with sleep period(6.7mmHg[8.1] versus 3.95[7.5], p=0.047). 8 patients were dippers by spot check measurement, but 11 were dippers by continuous BP. Conclusion Standard ambulatory periodic nocturnal BP recording may not yield true sleep BP patterns due to its spot-check nature and lack of sleep-awake information, which leads to inaccurate dipping measurements. Incorporation of beat-to-beat continuous BP measurement can provide more accurate and meaningful nocturnal BP information. Support N/A


1991 ◽  
Vol 260 (3) ◽  
pp. E333-E337 ◽  
Author(s):  
C. K. Klingbeil ◽  
V. L. Brooks ◽  
E. W. Quillen ◽  
I. A. Reid

Angiotensin II causes marked stimulation of drinking when it is injected centrally but is a relatively weak dipsogen when administered intravenously. However, it has been proposed that the dipsogenic action of systemically administered angiotensin II may be counteracted by the pressor action of the peptide. To test this hypothesis, the dipsogenic action of angiotensin II was investigated in dogs, in which low and high baroreceptor influences had been eliminated by denervation of the carotid sinus, aortic arch, and heart. In five sham-operated dogs, infusion of angiotensin II at 10 and 20 ng.kg-1.min-1 increased plasma angiotensin II concentration to 109.2 +/- 6.9 and 219.2 +/- 38.5 pg/ml and mean arterial pressure by 20 and 29 mmHg, respectively, but did not induce drinking. In four baroreceptor-denervated dogs, the angiotensin II infusions produced similar increases in plasma angiotensin II concentration and mean arterial pressure but, in contrast to the results in the sham-operated dogs, produced a dose-related stimulation of drinking. Water intake with the low and high doses of angiotensin II was 111 +/- 44 and 255 +/- 36 ml, respectively. The drinking responses to an increase in plasma osmolality produced by infusion of hypertonic sodium chloride were not different in the sham-operated and baroreceptor-denervated dogs. These results demonstrate that baroreceptor denervation increases the dipsogenic potency of intravenous angiotensin II and provides further support for the hypothesis that the dipsogenic action of intravenous angiotensin II is counteracted by the rise in blood pressure.


Author(s):  
Ian Mark Greenlund ◽  
Carl A. Smoot ◽  
Jason R. Carter

K-complexes are a key marker of non-rapid eye movement sleep (NREM), specifically during stages II sleep. Recent evidence suggests the heart rate responses to a K-complexes may differ between men and women. The purpose of this study was to compare beat-to-beat blood pressure responses to K-complexes in men and women. We hypothesized that the pressor response following a spontaneous K-complex would be augmented in men compared to women. Ten men (Age: 23 ± 2 years, BMI: 28 ± 4 kg/m2) and ten women (Age: 23 ± 5 years, BMI: 25 ± 4 kg/m2) were equipped with overnight finger plethysmography and standard 10-lead polysomnography. Hemodynamic responses to a spontaneous K-complex during stable stage II sleep were quantified for 10 consecutive cardiac cycles, and measurements included systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate. K-complex elicited greater pressor responses in men when blood pressures were expressed as SAP (cardiac cycle × sex: p = 0.007) and DAP (cardiac cycle × sex: p = 0.004). Heart rate trended to be different between men and women (cardiac cycle × sex: p = 0.078). These findings suggest a divergent pressor response between men and women following a spontaneous K-complex during normal stage II sleep. These findings could contribute to sex-specific differences in cardiovascular risk that exist between men and women.


2018 ◽  
Vol 41 (10) ◽  
pp. 635-643 ◽  
Author(s):  
Yoshitsugu Nakamura ◽  
Sam Emmanuel ◽  
Fumiaki Shikata ◽  
Chihiro Shirai ◽  
Yujiro Ito ◽  
...  

Objective: To investigate whether radial artery pressure is a reliable surrogate measure of central arterial pressure as approximated by femoral artery pressure in minimally invasive cardiac surgery with retrograde perfusion via femoral cannulation. Method: Fifty-two consecutive patients undergoing minimally invasive cardiac surgery were prospectively included in this study. Cardiopulmonary bypass was established via a femoral artery cannulation and femoral vein. Radial and femoral arterial pressures were recorded continuously, and the pressure differential between them was calculated for both systolic and mean arterial pressures. The agreement between measurements from the two arteries was compared using Bland–Altman plots. An interval of 95% limits of agreement of less than 20 mm Hg was set as satisfactory agreement. Results: Average age was 65 ± 14 years. With respect to systolic arterial pressure, 28 patients (54%) had a peak pressure differential between radial and femoral arteries ⩾20 mm Hg. With respect to mean arterial pressure, only five patients (9%) had a peak pressure differential ⩾20 mm Hg. The pressure differential changed with time. Pressure differential in systolic arterial pressure was 5 ± 8 mm Hg until aortic declamping, then increased to a peak of 23 ± 16 mm Hg when cardiopulmonary bypass was turned off. The femoral systolic arterial pressures were significantly greater than radial systolic arterial pressures from time of aortic declamping to 20 min after cardiopulmonary bypass. The Bland–Altman plots revealed large biases and poor agreement in this period. Conclusion: Radial and femoral systolic artery pressure readings can differ significantly in minimally invasive cardiac surgery with retrograde perfusion. Intraoperative arterial pressure management based solely on radial systolic arterial pressure readings should be avoided.


1999 ◽  
Vol 277 (3) ◽  
pp. R675-R681 ◽  
Author(s):  
Virginia L. Brooks ◽  
Colleen M. Kane ◽  
Lisa S. Welch

Late pregnant (P) conscious rabbits are less able to maintain arterial pressure during hemorrhage than nonpregnant (NP) animals. This study tested the hypothesis that the difference is due in part to less reflex vasoconstriction when the rabbits are P. Rabbits ( n = 14) were instrumented with arterial and venous catheters as well as ultrasonic flow probes around the superior mesenteric, renal, and/or terminal aortic arteries. Pregnancy increased ( P < 0.05) blood volume [235 ± 5 (P) vs. 171 ± 3 (NP) ml], terminal aortic conductance [1.88 ± 0.11 (P) vs. 0.98 ± 0.06 (NP) ml ⋅ min−1 ⋅ mmHg−1], mesenteric conductance [1.20 ± 0.19 (P) vs. 0.80 ± 0.05 (NP) ml ⋅ min−1 ⋅ mmHg−1], and heart rate [191 ± 4 (P) vs. 162 ± 3 (NP) beats/min] and decreased arterial pressure [59 ± 1 (P) vs. 67 ± 2 (NP) mmHg; P < 0.05]. Renal conductance was unaltered. The rabbits were bled in both the NP and P states at 2% of the initial blood volume per minute until arterial pressure fell below 45 mmHg. Arterial pressure fell with less blood loss in P rabbits [28 ± 2% (P) vs. 39 ± 2% (NP) of initial blood volume; P < 0.001]. Terminal aortic conductance decreased ( P < 0.001) before the pressure fall in both groups, but the response was reduced in P rabbits. Mesenteric and renal conductances did not change in either group before the blood pressure fall. During the pressure fall, terminal aortic conductance increased ( P < 0.05) only in NP rabbits. Mesenteric conductance increased in both groups. In summary, rabbits in late gestation are less able to maintain arterial pressure during hemorrhage, at least in part because of reduced vasoconstriction in tissues perfused by the terminal aorta.


1998 ◽  
Vol 26 (5) ◽  
pp. 497-502 ◽  
Author(s):  
J. C. M. Yap ◽  
L. A. H. Critchley ◽  
S. C. Yu ◽  
R. M. Calcroft ◽  
J. L. Derrick

We aimed to compare the efficacy of fluid preloading with two recently recommended fluid-vasopressor regimens for maintaining blood pressure during subarachnoid anaesthesia in the elderly. Sixty elderly patients requiring surgery for traumatic hip fractures received subarachnoid anaesthesia using 0.05 ml/kg of 0.5% heavy bupivacaine. Hypotension, i.e. systolic arterial pressure <75% of baseline, was prevented or treated by: A—normal saline 16 ml/kg plus intravenous ephedrine boluses (0.1 mg/kg); B—normal saline 8 ml/kg plus intramuscular depot ephedrine (0.5 mg/kg); or C—Haemaccel 8 ml/kg plus metaraminol infusion. Systolic arterial pressure and heart rate were recorded using custom-written computer software (Monitor, version 1.0). Systolic arterial pressure decreased in all groups after five minutes (P<0.001). Decreases were greatest in group A (P<0.05). Heart rate increased by 7% group A and decreased by 9% in group C (P<0.05). During the first hour, hypotension was present for 47%, 25% and 20% of the time in groups A, B and C respectively and overcorrection of systolic arterial pressure occurred in 19% of the time in group C. We conclude that treatment A was inadequate in preventing hypotension. Treatments B and C were more effective but were associated with an increased heart rate and overcorrection of systolic arterial pressure respectively.


Sign in / Sign up

Export Citation Format

Share Document