scholarly journals Solidified structure of a 5052 aluminum alloy obtained by semisolid casting

2005 ◽  
Vol 55 (2) ◽  
pp. 86-90 ◽  
Author(s):  
LongYun PIAO ◽  
Tetsuichi MOTEGI
2004 ◽  
Vol 449-452 ◽  
pp. 145-148 ◽  
Author(s):  
Ryoji Nakamura ◽  
Kenta Takahashi ◽  
Masahiko Ikawa

An unequal diameter twin roll caster was devised in order to increase productivity of the strip. This caster could cast the strip thicker than 6mm at the speed of 5m/min. The feature of this caster is that the lower roll was four times larger than the upper roll. The solidification length of the strip could be set longer easily than the conventional twin roll caster for aluminum alloy. Lowsolidification rate semisolid casting and low superheat casting were adopted. These were effective to increase the casting speed without decreasing the thickness of the strip. In the present study, the unequal diameter twin roll caster was designed and assembled. The test castings were operated and the characteristics of this caster were shown.


Author(s):  
G. G. Shaw

The morphology and composition of the fiber-matrix interface can best be studied by transmission electron microscopy and electron diffraction. For some composites satisfactory samples can be prepared by electropolishing. For others such as aluminum alloy-boron composites ion erosion is necessary.When one wishes to examine a specimen with the electron beam perpendicular to the fiber, preparation is as follows: A 1/8 in. disk is cut from the sample with a cylindrical tool by spark machining. Thin slices, 5 mils thick, containing one row of fibers, are then, spark-machined from the disk. After spark machining, the slice is carefully polished with diamond paste until the row of fibers is exposed on each side, as shown in Figure 1.In the case where examination is desired with the electron beam parallel to the fiber, preparation is as follows: Experimental composites are usually 50 mils or less in thickness so an auxiliary holder is necessary during ion milling and for easy transfer to the electron microscope. This holder is pure aluminum sheet, 3 mils thick.


2015 ◽  
Vol 30 (6) ◽  
pp. 627
Author(s):  
YE Zuo-Yan ◽  
LIU Dao-Xin ◽  
LI Chong-Yang ◽  
ZHANG Xiao-Hua ◽  
ZANG Xiao-Ming ◽  
...  

Equipment ◽  
2006 ◽  
Author(s):  
S. R. Carvalho ◽  
S. M. M. Lima e Silva ◽  
G. Guimaraes

1999 ◽  
Author(s):  
P. H. Chong ◽  
H. C. Man ◽  
S. F. Chan
Keyword(s):  

2008 ◽  
Author(s):  
Naoyuki Matsumoto ◽  
Yousuke Kawahito ◽  
Masami Mizutani ◽  
Seiji Katayama

Sign in / Sign up

Export Citation Format

Share Document