scholarly journals Liver stiffness in chronic hepatitis C virus infection

2019 ◽  
Vol 57 (2) ◽  
pp. 85-98
Author(s):  
Romeo-Gabriel Mihăilă

Abstract Introduction. The severity of liver fibrosis can be assessed noninvasively today by liver stiffness measurements. Vibration-controlled transient elastography, shear wave elastography or magnetic resonance elastography are techniques increasingly used for this purpose. Methods. This article presents the recent advances in the use of new techniques for liver fibrosis assessment in chronic hepatitis C: the correlation between liver stiffness values and liver fibrosis estimated by liver biopsies, the prognosis role of liver stiffness values, their usefulness in monitoring the treatment response, in assessing the severity of portal hypertension and in estimating the presence of esophageal varices. Scientific articles from January 2017 to January 2018 were searched in PubMed and PubMed Central databases, using the terms “liver stiffness” and “hepatitis C”. Results. The median liver stiffness values measured with different techniques are not identical, so that FibroScan thresholds cannot be used on any other elastographic machine. The higher the liver’s stiffness measurement, the higher the liver-related events in patients with chronic hepatitis C. A liver stiffness measurement over 17 kPa could be an independent predictor for the presence of esophageal varices as well as a spleen with a longitudinal span ≥ 15 cm for patients with a value of liver stiffness < 17 kPa. A progressive and persistent decrease in liver stiffness is dependent on sustained virological response achievement. The lack of liver stiffness decrease has been associated with relapsers and a low value of liver stiffness at baseline. Conclusion. Liver stiffness provides clues about the severity and evolution of liver disease.

Diagnostics ◽  
2020 ◽  
Vol 10 (5) ◽  
pp. 313
Author(s):  
Rosanna Villani ◽  
Francesco Cavallone ◽  
Antonino Davide Romano ◽  
Francesco Bellanti ◽  
Gaetano Serviddio

In recent years, several non-invasive methods have been developed for staging liver fibrosis in patients with chronic hepatitis C. A 2D-Shear wave elastography (SWE) technique has been recently introduced on the EPIQ 7 US system (ElastQ), but its accuracy has not been validated in patients with chronic hepatitis C virus (HCV) infection. We enrolled 178 HCV patients to assess their liver fibrosis stage with ElastQ software using transient elastography as a reference standard. The best cut-off values to diagnose ≥ F2, ≥ F3, and F4 were 8.15, 10.31, and 12.65 KPa, respectively. Liver stiffness values had a positive correlation with transient elastography (r = 0.57; p < 0.001). The area under the receiver operating characteristics (AUROC) was 0.899 for ≥ F2 (moderate fibrosis), 0.900 for ≥ F3 (severe fibrosis), and 0.899 for cirrhosis. 2D-SWE has excellent accuracy in assessing liver fibrosis in patients with chronic hepatitis C and an excellent correlation with transient elastography.


2016 ◽  
Vol 25 (3) ◽  
pp. 331-335 ◽  
Author(s):  
Giovanna Ferraioli ◽  
Laura Maiocchi ◽  
Raffaella Lissandrin ◽  
Carmine Tinelli ◽  
Annalisa De Silvestri ◽  
...  

Background & Aims: Noninvasive assessment of liver stiffness has been increasingly used to evaluate fibrosis instead of liver biopsy, especially in patients with chronic viral hepatitis. The aim of this study was to assess the performance in staging liver fibrosis of the updated ElastPQ® technique (EPIQ7 ultrasound system, Philips Healthcare, Bothell, WA, USA) in the “real life” setting by using the FibroScan as the reference standard and to understand whether the use of the quality criteria improves the performance of the technique. Methods: This was a cross-sectional study: 278 patients affected by chronic hepatitis C referred for liver stiffness measurement with the FibroScan® 502 Touch device (Echosens, Paris, France) underwent measurements also with the ElastPQ® technique. For the assessment of significant fibrosis (F≥2), advanced fibrosis (F≥3) and cirrhosis (F=4), respectively, we used the cutoffs of 7.0, 9.5 and 12.0 kPa. The diagnostic performance of ElastPQ® was assessed using the area under the ROC (AUROC) curve analysis and was evaluated overall and for cases with (a) 10 measurements and IQR/M≤30%, (b) 5 measurements and IQR/M ≤30%, (c) 10 measurements and IQR/M>30%, (d) 5 measurements and IQR/M>30%. Results: The optimal cutoffs of ElastPQ® for significant fibrosis, advanced fibrosis and cirrhosis were 6.43, 9.54 and 11.34 kPa, respectively. For measurements with an IQR/M≤30%, there was no statistically significant decrease in sensitivity between 10 and 5 measurements (p=0.26, p=0.09, p=0.71, for F≥2, F≥3, and F=4, respectively). Conclusion: The ElastPQ® technique is reliable and accurate for staging liver fibrosis. The number of measurements does not affect the performance. Abbreviations: ALP: alkaline phosphatase; ALT: alanine aminotransferase; AST: aspartate aminotransferase; AUROC: area under the ROC curve; BMI: body mass index; GGT: gamma-glutamyl transferase; LR: likelihood ratio; LSM: liver stiffness measurement; pSWE: point shear wave elastography; ROC: receiver operating characteristic; VCTE: vibration controlled transient elastography; VTQ®: virtual touch quantification.


2006 ◽  
Vol 44 ◽  
pp. S214 ◽  
Author(s):  
V. Grando-Lemaire ◽  
V. De Lédinghen ◽  
V. Bourcier ◽  
N. Ganne-Carrie ◽  
J.C. Trinchet ◽  
...  

Medicine ◽  
2017 ◽  
Vol 96 (46) ◽  
pp. e8621 ◽  
Author(s):  
Mohammed Tag-Adeen ◽  
Mohamed Alsenbesy ◽  
Ali Abdelrahman Ghweil ◽  
M. Ali Hussein Abd Elrazek ◽  
Elsayed A. Elgohary ◽  
...  

PLoS ONE ◽  
2018 ◽  
Vol 13 (11) ◽  
pp. e0206947 ◽  
Author(s):  
Pin-Nan Cheng ◽  
Hung-Chih Chiu ◽  
Yen-Cheng Chiu ◽  
Shu-Chuan Chen ◽  
Yi Chen

2020 ◽  
Vol 92 (2) ◽  
pp. 24-28
Author(s):  
I. V. Maev ◽  
E. I. Kuznetsova ◽  
D. N. Andreev ◽  
D. T. Dicheva

Aim.Assessment of the diagnostic accuracy of predictive indexes of liver fibrosis for the identification of severe fibrosis and cirrhosis (F3F4) in patients with chronic hepatitis C (CHC). Materials and methods.The retrospective design study included 127 patients with chronic hepatitis C (mean age 44.511.1 years). To assess the degree of liver fibrosis, all patients underwent transient elastography using a Fibroscan (EchoSens, France) and predictive indexes of liver fibrosis were calculated (APRI, FIB-4, discriminant Bonacini score). Transient elastography was considered as a reference method for assessing the degree of liver fibrosis for subsequent comparison of results with predictive fibrosis indixes. Results.The sensitivity of the APRI index for the identification of severe fibrosis and cirrhosis of the liver (F3F4) was 79%, and specificity was 69%. The FIB-4 index showed greater specificity (86%), but less sensitivity (68%). The sensitivity of the discriminant Bonacini scale was 81%, and the specificity was 77%. The positive predictive value of the APRI index, FIB-4 and the Bonacini scale for the identification of severe fibrosis and cirrhosis of the liver (F3F4) in patients with chronic hepatitis C was 66; 78 and 72% respectively, and negative predictive value 82; 78 and 84% respectively. Conclusion.The results of this study indicate the relatively high diagnostic accuracy of a number of predictive indexes for evaluating liver fibrosis (APRI, FIB-4, discriminant Bonachini scale) in identifying severe fibrosis and cirrhosis of the liver (F3F4) in patients with chronic hepatitis C.


Sign in / Sign up

Export Citation Format

Share Document