scholarly journals Modeling the sustainable performance of residential building envelope: the role of performance indicator

Author(s):  
A. Mwasha ◽  
R. Williams ◽  
J. Iwaro
2020 ◽  
Vol 10 (13) ◽  
pp. 4489
Author(s):  
Zakaria Che Muda ◽  
Payam Shafigh ◽  
Norhayati Binti Mahyuddin ◽  
Samad M.E. Sepasgozar ◽  
Salmia Beddu ◽  
...  

The increasing need for eco-friendly green building and creative passive design technology in response to climatic change and global warming issues will continue. However, the need to preserve and sustain the natural environment is also crucial. A building envelope plays a pivotal role in areas where the greatest heat and energy loss often occur. Investment for the passive design aspect of building envelopes is essential to address CO 2 emission. This research aims to explore the suitability of using integral-monolithic structural insulation fibre-reinforced lightweight aggregate concrete (LWAC) without additional insulation as a building envelope material in a high-rise residential building in the different climatic zones of the world. Polypropylene and steel fibres in different dosages were used in a structural grade expanded clay lightweight aggregate concrete. Physical and thermal properties of fibre reinforced structural LWAC, normal weight concrete (NWC) and bricks were measured in the lab. The Autodesk@Revit-GBS simulation program was implemented to simulate the energy consumption of a 29-storey residential building with shear wall structural system using the proposed fibre-reinforced LWAC materials. Results showed that energy savings between 3.2% and 14.8% were incurred in buildings using the fibre-reinforced LWAC across various climatic regions as compared with traditional NWC and sand-cement brick and clay brick walls. In conclusion, fibre-reinforced LWAC in hot-humid tropical and temperate Mediterranean climates meet the certified Green Building Index (GBI) requirements of less than 150 kW∙h∙m−2. However, in extreme climatic conditions of sub-arctic and hot semi-arid desert climates, a thicker wall or additional insulation is required to meet the certified green building requirements. Hence, the energy-saving measure is influenced largely by the use of fibre-reinforced LWAC as a building envelope material rather than because of building orientation.


2014 ◽  
Vol 986-987 ◽  
pp. 1026-1028
Author(s):  
Hai Qing Guo

Energy-saving hierarchical design model is established for differentiate architecture. From current status of China's construction, exploration research is established on energy-saving hierarchical design model of differentiate architecture to evaluate indicator system of energy-saving building. Availability of evaluation information in index system is low, so it is difficult to play the role of evaluation of building energy-efficiency. EHTV difference method is used to calculate and evaluate energy-saving design of hierarchical building, including: heat transfer indicator of building envelope targets, air conditioning and heating consumption, basis of EHTV indicators.


2013 ◽  
Vol 787 ◽  
pp. 711-716
Author(s):  
Daryanto ◽  
Eko Budihardjo ◽  
Wahyu Setyabudi ◽  
Gagoek Hardiman

There was an indication that high rise buildings in Jakarta was not designed based on energy conservation principles. The most important aspects of the high-rise buildings is energy saving technology located in the building envelope design. Building envelope with a full glass design functions for widening view and enhancing natural lights, even though but it is also increasing energy consumption and thermal discomfort due to the intensity of solar radiation in hot humid climates. During the current decade, the development of double building envelope type (Double Skin Façade: DSF) seemed more just to improve the aesthetics and the use of natural light, while the wind and thermal performance aspects were still lack of serious consideration. Those aspects will be chosen as the subject matter in this research. The research was aimed to investigate and compare the value of heat transfer in the building envelope of high-rise office buildings. Samples were taken from five DSF buildings, with closed and open cavity. CFD software is used for simulation of the five different models of DSF. The research proves that the high-rise office buildings as the research object in Jakarta do not apply energy conservation principle. The utilization of wind in the DSF cavity can reduce temperature and relieve the burden of air conditioning systems that is energy save. An important finding of the research is the need for ventilation in the design of a double skin at high-rise office buildings in the humid tropics.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Shampy Kamboj ◽  
Shruti Rana

PurposeThe main objective of this paper is to study the role of supply chain performance (SCP) as a mediator between big data-driven supply chain (BDDSC) and firm sustainable performance. In addition, the role of firm age as a moderator between BDDSC and SCP as well as between SCP and firm sustainable performance has also been explored.Design/methodology/approachThe 200 managers of medium or senior level positions in micro, small and medium enterprises (MSMEs) located at Delhi-NCR have been contacted. Further, collected data have been confirmed with confirmatory factor analysis (CFA). In this paper, structure equation modeling (SEM) has been employed to empirically check the proposed hypotheses and their relationships.FindingsThe findings confirmed that SCP mediates the link between BDDSC and firm sustainable performance. Additionally, firm age moderates the association between BDDSC and SCP as well as between SCP and firm sustainable performance.Research limitations/implicationsThe role of SCP and firm age between BDDSC and sustainable performance have been examined in the context of MSMEs in Delhi-NCR and thereby limit the generalization of results to other industries and country contexts.Originality/valueThe present study adds to the existing literature via recognizing the blackbox using SCP and firm age to comprehend BDDSC and firm sustainable performance relationship.


2018 ◽  
Vol 14 (1) ◽  
Author(s):  
Yohanis S. Ulimpa ◽  
Jullie J. Sondakh ◽  
Treesje Runtu

In line with regional autonomy that is oriented towards empowerment (emporwerment) and community guidance in the implementation of clean authority and free of corruption, collusion and nepotism, the public sector is often regarded as a nest of wasteful efficiency and institutional fund leakage that always loses money. But the public sector still has wide opportunities to improve the performance of the benefits of resources economically, effectively and efficiently. Knowing the performance measurement of the Sorong Regency government. Knowing the role of indicators in the Sorong Regency government. The method used in this study is descriptive qualitative. The result is the performance measurement of the local government is carried out because of the provisions of the central government to make performance accountability reports for each government agency.Keywords :Performance Measurement, Performance Indicator, LAKIP, Sorong District Government   


Author(s):  
Darija Gajić ◽  
Erdin Salihović ◽  
Nermina Zagora

Yielding from an overall quantitative study of the residential sector of Bosnia and Herzegovina (B&H), this chapter concentrates on the ratio between single-family and collective housing, as well as on the urban-rural ratio of the single-family housing. Based on the data from the existing building stock (buildings built by 2014) and the statistical estimates, 23% of the buildings belong to the urban areas and 77% belong to the rural areas. The main goal was to study the correlation between the characteristics of the building envelope, the shape factor (A/V ratio) and the energy savings potential for the application of conventional measures of refurbishment of the building envelope of the single-family houses (type of buildings, which dominate in rural and urban areas). The chapter wraps up with recommendations for the adequate level of the energy performance indicator (energy need for heating) for the approved energy class for single-family houses located in the climate zone of the northern B&H.


Sign in / Sign up

Export Citation Format

Share Document