scholarly journals Analytical QbD Approach for Development and Validation of RP-High Performance Liquid Chromatography Method for Determination of Tofisopam in Pure Form and Tablets

Author(s):  
Megha Kokane ◽  
Jeeja Pananchery ◽  
Monika Jadhav ◽  
Ashish Jain

A novel, simple, optimized reversed-phase chromatography method for assay of Tofisopam in pure and tablet form is developed. The experimental trial was by Box Behnken design using the Design Expert® software 10 version. The attributes selected were peak symmetry, number of theoretical, and peak purity. The predicted data satisfied with actual experimental data. The optimized chromatographic conditions required a quaternary pump with a mobile phase of Water: Acetonitrile 25:75 v/v at 1 mL/min, oven temperature at 25oC at 310 nm using C18(250 × 4.6 mm Id, 5μm) column and PDA detector with a run time of 5 min. The method was validated for linearity, precision, accuracy, and specificity. The method produced a linear response over a concentration range of 4–24 ppm with an overall average accuracy of 99.98%. The method was robust, reproducible, and specific with respect to the retention time of tofisopam.

2014 ◽  
Vol 6 (16) ◽  
pp. 6560-6564 ◽  
Author(s):  
Wuxiang Zhang ◽  
Yicong Su ◽  
Jiangu Shi ◽  
Maosheng Zhang ◽  
Bide Wu ◽  
...  

In this paper, a high performance liquid chromatography technique is established for quantification of paraquat in blood.


INDIAN DRUGS ◽  
2021 ◽  
Vol 57 (10) ◽  
pp. 47-57

An isocratic Reversed-Phase High Performance Liquid Chromatography method has been developed for rapid and simultaneous separation and estimation of two antibiotics, namely, nitazoxanide and ofloxacin, in human plasma. Separation was carried out on Altima C8 (150 x 4.6 mm, 5µ) column using a mobile phase of 0.1% ortho phosphoric acid: acetonitrile (50:50, V/V) at 260 nm. The retention time of nitazoxanide and ofloxacin was noted to be 4.850 and 7.949 min, respectively. The average % recovery for nitazoxanide and ofloxacin were 98.012 % and 94.176 %, respectively and reproducibility was found to be satisfactory. The linearity was investigated in the concentration range of 0.02-2 µg/ml (r2=0.9996) for nitazoxanide and 0.008-0.8 µg/ml (r2=0.9998) for ofloxacin. The lower limits of quantification were 0.0196 µg/ml and 0.0079 µg/ml for nitazoxanide and ofloxacin, respectively, which reach the level of both drugs possibly found in human plasma. The proposed method can be applied for etermination of nitazoxanide and ofloxacin from dosage forms during pharmacokinetic study.


2013 ◽  
Vol 9 (2) ◽  
pp. 26-29 ◽  
Author(s):  
AK Hemanth Kumar ◽  
V Sudha ◽  
Geetha Ramachandran

A high performance liquid chromatographic method for determination of rifabutin in human plasma was  developed. The method involved deproteinisation of the sample with acetonitrile and analysis of the  supernatant using a reversed-phase C18 column (250mm) and UV detection at a wavelength of 265nm.  The assay was specific for rifabutin and linear from 0.025 to 10.0μg/ml. The relative standard deviation  of intra- and inter-day assays was lower than 10%. The method was able to remove interfering materials  in plasma, yielding an average recovery of rifabutin from plasma of 101%. Due to its simplicity, the assay  can be used for pharmacokinetic studies of rifabutin. SAARC Journal of Tuberculosis, Lung Diseases & HIV/AIDS; 2012; IX(2) 26-29 DOI: http://dx.doi.org/10.3126/saarctb.v9i2.7975