Noise Shielding Effects for Engine-Over-Wing Installations

1975 ◽  
Author(s):  
V. CONTICELLI ◽  
A. DI BLASI ◽  
J. OKEEFE

2021 ◽  
Vol 13 (9) ◽  
pp. 5284
Author(s):  
Timothy Van Renterghem ◽  
Francesco Aletta ◽  
Dick Botteldooren

The deployment of measures to mitigate sound during propagation outdoors is most often a compromise between the acoustic design, practical limitations, and visual preferences regarding the landscape. The current study of a raised berm next to a highway shows a number of common issues like the impact of the limited length of the noise shielding device, initially non-dominant sounds becoming noticeable, local drops in efficiency when the barrier is not fully continuous, and overall limited abatement efficiencies. Detailed assessments of both the objective and subjective effect of the intervention, both before and after the intervention was deployed, using the same methodology, showed that especially the more noise sensitive persons benefit from the noise abatement. Reducing the highest exposure levels did not result anymore in a different perception compared to more noise insensitive persons. People do react to spatial variation in exposure and abatement efficiency. Although level reductions might not be excessive in many real-life complex multi-source situations, they do improve the perception of the acoustic environment in the public space.


Author(s):  
Mark-Robert Kalus ◽  
Riskyanti Lanyumba ◽  
Stephan Barcikowski ◽  
Bilal Gökce

AbstractOver the past decade, laser ablation in liquids (LAL) was established as an innovative nanoparticle synthesis method obeying the principles of green chemistry. While one of the main advantages of this method is the absence of stabilizers leading to nanoparticles with “clean” ligand-free surfaces, its main disadvantage is the comparably low nanoparticle production efficiency dampening the sustainability of the method and preventing the use of laser-synthesized nanoparticles in applications that require high amounts of material. In this study, the effects of productivity-dampening entities that become particularly relevant for LAL with high repetition rate lasers, i.e., persistent bubbles or colloidal nanoparticles (NPs), on the synthesis of colloidal gold nanoparticles in different solvents are studied. Especially under batch ablation conditions in highly viscous liquids with prolonged ablation times both shielding entities are closely interconnected and need to be disentangled. By performing liquid flow-assisted nanosecond laser ablation of gold in liquids with different viscosity and nanoparticle or bubble diffusivity, it is shown that a steady-state is reached after a few seconds with fixed individual contributions of bubble- and colloid-induced shielding effects. By analyzing dimensionless numbers (i.e., Axial Peclet, Reynolds, and Schmidt) it is demonstrated how these shielding effects strongly depend on the liquid’s transport properties and the flow-induced formation of an interface layer along the target surface. In highly viscous liquids, the transport of NPs and persistent bubbles within this interface layer is strongly diffusion-controlled. This diffusion-limitation not only affects the agglomeration of the NPs but also leads to high local densities of NPs and bubbles near the target surface, shielding up to 80% of the laser power. Hence, the ablation rate does not only depend on the total amount of shielding matter in the flow channel, but also on the location of the persistent bubbles and NPs. By comparing LAL in different liquids, it is demonstrated that 30 times more gas is produced per ablated amount of substance in acetone and ethylene glycol compared to ablation in water. This finding confirms that chemical effects contribute to the liquid’s decomposition and the ablation yield as well. Furthermore, it is shown that the highest ablation efficiencies and monodisperse qualities are achieved in liquids with the lowest viscosities and gas formation rates at the highest volumetric flow rates.


1994 ◽  
Vol 23 (6) ◽  
pp. 406-408 ◽  
Author(s):  
M. Herzog ◽  
J. Moser ◽  
B. Wagner ◽  
J. Broecker

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Hong Zhang ◽  
Sheng Zou ◽  
Xi-Yuan Chen ◽  
Wei Quan

The ultrahigh sensitivity atomic spin magnetometer as the magnetic measurement sensor has received much concern. The performance of the magnetic shielding cylinder is one of the key factors constraining the atomic spin magnetometer’s sensitivity. In order to effectively improve the performances of the magnetic shielding, the parameter optimization models of the magnetic shielding cylinder were established in this paper. Under the condition of changing only one parameter while the others keeping constant, the effects of various parameters influencing the axial shielding coefficient were comprehensively analyzed, and the results showed that the smaller the innermost length, the innermost radius, and the radial spacing were, and the greater the axial spacing was, the better the shielding performance could be obtained. According to these results and the actual needs, the magnetic shielding cylinder was optimally designed, and then the shielding effects were simulated via the software Ansoft. The simulation results showed that the optimized magnetic shielding cylinder had the advantages of small size, high shielding performance, and lager uniformity than that of the nonoptimized one. The actual measurement results showed that the residual magnetism in the optimized magnetic shielding cylinder was below 0.1 nT, which was 2~4 times lower than the nonoptimized one.