Rate of Force Application During Knee Arthrometer Testing Affects Stiffness but Not Displacement Measurements

Author(s):  
Steven M. Gross
2004 ◽  
Vol 34 (3) ◽  
pp. 132-139 ◽  
Author(s):  
Steven M. Gross ◽  
Christopher R. Carcia ◽  
Bruce M. Gansneder ◽  
Sandra J. Shultz

2017 ◽  
Vol 37 (1) ◽  
pp. 1-12 ◽  
Author(s):  
Haluk Ay ◽  
Anthony Luscher ◽  
Carolyn Sommerich

Purpose The purpose of this study is to design and develop a testing device to simulate interaction between human hand–arm dynamics, right-angle (RA) computer-controlled power torque tools and joint-tightening task-related variables. Design/methodology/approach The testing rig can simulate a variety of tools, tasks and operator conditions. The device includes custom data-acquisition electronics and graphical user interface-based software. The simulation of the human hand–arm dynamics is based on the rig’s four-bar mechanism-based design and mechanical components that provide adjustable stiffness (via pneumatic cylinder) and mass (via plates) and non-adjustable damping. The stiffness and mass values used are based on an experimentally validated hand–arm model that includes a database of model parameters. This database is with respect to gender and working posture, corresponding to experienced tool operators from a prior study. Findings The rig measures tool handle force and displacement responses simultaneously. Peak force and displacement coefficients of determination (R2) between rig estimations and human testing measurements were 0.98 and 0.85, respectively, for the same set of tools, tasks and operator conditions. The rig also provides predicted tool operator acceptability ratings, using a data set from a prior study of discomfort in experienced operators during torque tool use. Research limitations/implications Deviations from linearity may influence handle force and displacement measurements. Stiction (Coulomb friction) in the overall rig, as well as in the air cylinder piston, is neglected. The rig’s mechanical damping is not adjustable, despite the fact that human hand–arm damping varies with respect to gender and working posture. Deviations from these assumptions may affect the correlation of the handle force and displacement measurements with those of human testing for the same tool, task and operator conditions. Practical implications This test rig will allow the rapid assessment of the ergonomic performance of DC torque tools, saving considerable time in lineside applications and reducing the risk of worker injury. DC torque tools are an extremely effective way of increasing production rate and improving torque accuracy. Being a complex dynamic system, however, the performance of DC torque tools varies in each application. Changes in worker mass, damping and stiffness, as well as joint stiffness and tool program, make each application unique. This test rig models all of these factors and allows quick assessment. Social implications The use of this tool test rig will help to identify and understand risk factors that contribute to musculoskeletal disorders (MSDs) associated with the use of torque tools. Tool operators are subjected to large impulsive handle reaction forces, as joint torque builds up while tightening a fastener. Repeated exposure to such forces is associated with muscle soreness, fatigue and physical stress which are also risk factors for upper extremity injuries (MSDs; e.g. tendinosis, myofascial pain). Eccentric exercise exertions are known to cause damage to muscle tissue in untrained individuals and affect subsequent performance. Originality/value The rig provides a novel means for quantitative, repeatable dynamic evaluation of RA powered torque tools and objective selection of tightening programs. Compared to current static tool assessment methods, dynamic testing provides a more realistic tool assessment relative to the tool operator’s experience. This may lead to improvements in tool or controller design and reduction in associated musculoskeletal discomfort in operators.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3554
Author(s):  
Melissa M. Suckey ◽  
Donald W. Benza ◽  
John D. DesJardins ◽  
Jeffrey N. Anker

We describe a method to measure micron to millimeter displacement through tissue using an upconversion spectral ruler. Measuring stiffness (displacement under load) in muscles, bones, ligaments, and tendons is important for studying and monitoring healing of injuries. Optical displacement measurements are useful because they are sensitive and noninvasive. Optical measurements through tissue must use spectral rather than imaging approaches because optical scattering in the tissue blurs the image with a point spread function typically around the depth of the tissue. Additionally, the optical measurement should have low background and minimal intensity dependence. Previously, we demonstrated a spectral encoder using either X-ray luminescence or fluorescence, but the X-ray luminescence required an expensive X-ray source and used ionizing radiation, while the fluorescence sensor suffered from interference from autofluorescence. Here, we used upconversion, which can be provided with a simple fiber-coupled spectrometer with essentially autofluorescence-free signals. The upconversion phosphors provide a low background signal, and the use of closely spaced spectral peaks minimizes spectral distortion from the tissue. The small displacement noise level (precision) through tissue was 2 µm when using a microscope-coupled spectrometer to collect light. We also showed proof of principle for measuring strain on a tendon mimic. The approach provides a simple method to study biomechanics using implantable sensors.


1985 ◽  
Vol 40 (9) ◽  
pp. 913-919
Author(s):  
Juan Carlos López ◽  
José L. Alonso

Abstract The rotational transitions of 3,4-dihydro-1,2-pyran in the ground state and six vibrationally excited states have been assigned. The rotational constants for the ground state (A = 5198.1847(24), B = 4747.8716(24) and C = 2710.9161(24) have been derived by fitting μa, μb and μc-type transitions. The dipole moment was determined from Stark displacement measurements to be 1.400(8) D with its principal axis components |μa| =1.240(2), |μb| = 0.588(10) and |μc| = 0.278(8) D. A model calculation to reproduce the ground state rotational constants indicates that the data are consistent with a twisted ring conformation. The average intensity ratio gives vibrational separations between the ground and excited states of the ring-bending and ring-twisting modes of ~ 178 and ~ 277 cm-1 respectively.