STANDARD ASSESSMENT FOR ENERGY SAVING STRATEGIES OF INDUSTRIAL AIR-CONDITIONING SYSTEMS

Author(s):  
Jéssica Duarte ◽  
Lara Werncke Vieira ◽  
Rafael Zanardo ◽  
Augusto Delavald Marques ◽  
Paulo Smith Schneider
Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 81
Author(s):  
Rongjiang Ma ◽  
Shen Yang ◽  
Xianlin Wang ◽  
Xi-Cheng Wang ◽  
Ming Shan ◽  
...  

Air-conditioning systems contribute the most to energy consumption among building equipment. Hence, energy saving for air-conditioning systems would be the essence of reducing building energy consumption. The conventional energy-saving diagnosis method through observation, test, and identification (OTI) has several drawbacks such as time consumption and narrow focus. To overcome these problems, this study proposed a systematic method for energy-saving diagnosis in air-conditioning systems based on data mining. The method mainly includes seven steps: (1) data collection, (2) data preprocessing, (3) recognition of variable-speed equipment, (4) recognition of system operation mode, (5) regression analysis of energy consumption data, (6) constraints analysis of system running, and (7) energy-saving potential analysis. A case study with a complicated air-conditioning system coupled with an ice storage system demonstrated the effectiveness of the proposed method. Compared with the traditional OTI method, the data-mining-based method can provide a more comprehensive analysis of energy-saving potential with less time cost, although it strongly relies on data quality in all steps and lacks flexibility for diagnosing specific equipment for energy-saving potential analysis. The results can deepen the understanding of the operating data characteristics of air-conditioning systems.


2020 ◽  
Vol 10 (4) ◽  
pp. 1513 ◽  
Author(s):  
Daniel Sánchez-García ◽  
David Bienvenido-Huertas ◽  
Jesús A. Pulido-Arcas ◽  
Carlos Rubio-Bellido

Reports of Intergovernmental Panel on Climate Change have set various greenhouse gas emissions scenarios, through which the evolution of the temperature of the planet can be estimated throughout the 21st century. The reduction of the emissions from the different activities carried out by mankind is crucial to mitigate greenhouse gas emissions. One of the most significant activities is users’ behaviour within buildings, particularly the use of Heating, Ventilation and Air-Conditioning systems. Modifying users’ behaviour patterns to guarantee acceptable thermal conditions inside buildings could lead to considerable energy saving percentages, and adaptive thermal comfort models could be an opportunity to achieve important savings. For this reason, this study analyzes the potential to apply adaptive thermal comfort models to use artificial air-conditioning systems by modifying setpoint temperatures. The analysis was conducted in five major European cities (Barcelona, Berlin, Bern, Rome, and Vienna) and in five climate change scenarios in the year 2050. The results showed that, in general, the energy saving achieved by adaptive strategies was larger in the cities with a greater cooling demand. Also, in both Representative Concentration Pathways (RCP) of the Fifth Assessment Report (AR5) considered, the energy saving were decreased in the cities of Barcelona and Rome, with values lower than those of the Fourth Assessment Report (AR4) scenarios considered, whereas in the cities of Berlin, Bern, and Vienna, the saving in the RCP scenarios is greater than those in the other scenarios.


2021 ◽  
Author(s):  
Mohamed Elhelw ◽  
Wael M. El-Maghlany ◽  
Mohamed Shawky Ismail ‎

Abstract This paper introduces novel modification for conventional air conditioning systems through utilizing a thermal ice storage system integrated with solar panels. Alexandria and Aswan, cities in Egypt, are chosen to represent two climates for hot-humid and hot-dry climates respectively. The governing equations for both heat and mass transfer are theoretically solved. Exergy analysis is performed for the proposed solar-ice thermal storage system via determining exergy destruction on ice and solar components as well as the total destruction based on transient analysis. This study was carried out on two common types of air conditioning systems, an air handling unit and fan coil unit. Results showed that, solar-ice storage system is more effective approach in hot-humid climate than hot-dry climate and more efficient with all-water air conditioning system than with all-air conditioning system. The maximum energy saving is 205.16 GJ having a percent of 27.5% in August for all water system in case of Alexandria city and 224.67 GJ with a percent of 25.38% in August for all-water system in case of Aswan city. All air system simulation showed maximum energy saving of 175.05 GJ with a percent of 18.13 % in case of August for Alexandria and 175.45 GJ having a percentage of 17.43% in case of Aswan in August. Moreover, the all-water system achieved a reduction in CO2 emissions by 467 tons/year in Aswan city and 390 tons/year in case of Alexandria city. While these reductions decrease to be 435 and 353 tons/year when the all-air system used for the same two cities.


2015 ◽  
Vol 121 ◽  
pp. 438-445 ◽  
Author(s):  
Peng Yang ◽  
Li Li ◽  
Jianqin Wang ◽  
Guilin Huang ◽  
Jingli Peng

2014 ◽  
Vol 494-495 ◽  
pp. 1674-1677
Author(s):  
Bing Xu ◽  
Fang Hong Yuan ◽  
Bao Guo Zheng ◽  
Zhong Jin Shi ◽  
Yi Huan Hu

This article discusses energy conservation for air conditioning systems in rail transit stations. At first, the paper analyzes the energy consumption condition in the air conditioning systems in rail transit stations. Then, it discusses application of appropriate control strategy for reducing energy consumption. In the end, the paper calculates effiency and amount of the energy saving based on the control strategy.


2013 ◽  
Vol 278-280 ◽  
pp. 111-116
Author(s):  
Zheng Zhang ◽  
Jin Feng Wang ◽  
Jing Xie ◽  
Yi Tang

In this article, the application of Computational Fluid Dynamics (CFD) technology in the field of Heating Ventilation & Air Condition was introduced, and the research progress in optimizing the simulation of air-conditioned room was summarized. Some domestic and foreign studies on air conditioning operation and energy saving were illustrated about the effects of different installation locations, blow angles and air supply modes, which would provide a theoretical basis and scientific guidance for air-conditioning systems to optimize the design. Based on previous results, the development of further research on CFD in the simulation of air-conditioning in future was analyzed.