Comparison of steel strength retention models for fire exposed concrete slabs

Author(s):  
Thomas Thienpont ◽  
Ruben Van Coile ◽  
Robby Caspeele ◽  
Wouter De Corte

<p>In structural fire engineering, there is a growing trend towards the use of performance based approaches to evaluate structural behaviour during or after a fire. Consequently, there is a need for an increased level of confidence in properties of construction materials used in these performance based approaches. Both steel and concrete have been experimentally observed to show a dispersal in the value of their respective structural strengths, at room temperature, but more significantly at high temperatures. In this paper the influence of three temperature dependent strength retention models for reinforcement steel on the bending moment capacity of simply supported reinforced concrete slabs exposed to a standardized fire is analysed. The results show that the structural response of reinforced concrete slabs strongly depends on the chosen probabilistic model, thus highlighting the importance of appropriate model selection.</p>

2016 ◽  
Vol 711 ◽  
pp. 588-595
Author(s):  
Emran Baharudin ◽  
Luke Bisby ◽  
Tim Stratford

The historically good performance of concrete structures in real fires, and the lack of urgent drivers for the concrete industry to support research on the fire performance of concrete structures, means that research on the full frame response of concrete buildings to fires has received much less attention than for steel-framed structures. However, a credible understanding of, and ability to model, the response of concrete structures under fire exposure is crucial to make further progress in the field of structural fire engineering, and to make best use of the flexibility enabled by performance-based fire codes. This paper presents a computational study on the structural behaviour of reinforced concrete slabs during fire tests undertaken by Zhang et al.[16]. The distribution of stresses in the slabs is discussed, as is the need for further research to better understand structural response during fire. Amongst other factors, the assumed tensile strength of the concrete is crucial to accurately predict response. The results corroborate the existing consensus that concrete slabs in real buildings can, in some cases, withstand fires for longer than expected; this is due to mobilisation of membrane actions, amongst other factors.


2020 ◽  
Vol 221 ◽  
pp. 111058 ◽  
Author(s):  
Antonio Bilotta ◽  
Alberto Compagnone ◽  
Laura Esposito ◽  
Emidio Nigro

2021 ◽  
Vol 50 (1) ◽  
pp. 227-238
Author(s):  
Yanuar Haryanto ◽  
Nanang Gunawan Wariyatno ◽  
Hsuan-Teh Hu ◽  
Ay Lie Han ◽  
Banu Ardi Hidayat

Reinforced concrete is perhaps the most widely used building material in the world. However, the materials used for reinforcement of concrete i.e. steel is quite expensive and scarcely available in the developing world. As a result, bamboo is considered to be a cheaper replacement with high tensile strength. This research investigated the structural behaviour of bamboo-reinforced concrete slabs used for footplate foundation subjected to concentrated load. For this purpose, four different reinforced concrete slab panels were developed and analyzed. The influence of replacing steel with bamboo for the reinforcement of concrete slabs on their structural behaviour was assessed by determining the load-deflection characteristics, the ultimate load, the stiffness, the ductility, the cracking pattern, and the energy absorption capacity. The results showed that in comparison to steel reinforced concrete slabs, the strength of 82% can be acquired by the bamboo reinforced slabs. Furthermore, ductility demonstrated by the two types of specimens was almost equivalent i.e. up to 93%. Those indicated that the structural behaviour demonstrated by bamboo reinforced slabs is quite comparable to that of steel reinforced concrete slabs. Therefore, bamboo can prove to be a promising substitute for steel in concrete reinforcement. Future studies may further examine this opportunity.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4622
Author(s):  
Kevin Paolo V. Robles ◽  
Jurng-Jae Yee ◽  
Seong-Hoon Kee

The main objectives of this study are to evaluate the effect of geometrical constraints of plain concrete and reinforced concrete slabs on the Wenner four-point concrete electrical resistivity (ER) test through numerical and experimental investigation and to propose measurement recommendations for laboratory and field specimens. First, a series of numerical simulations was performed using a 3D finite element model to investigate the effects of geometrical constraints (the dimension of concrete slabs, the electrode spacing and configuration, and the distance of the electrode to the edges of concrete slabs) on ER measurements of concrete. Next, a reinforced concrete slab specimen (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) was used for experimental investigation and validation of the numerical simulation results. Based on the analytical and experimental results, it is concluded that measured ER values of regularly shaped concrete elements are strongly dependent on the distance-to-spacing ratio of ER probes (i.e., distance of the electrode in ER probes to the edges and/or the bottom of the concrete slabs normalized by the electrode spacing). For the plain concrete, it is inferred that the thickness of the concrete member should be at least three times the electrode spacing. In addition, the distance should be more than twice the electrode spacing to make the edge effect almost negligible. It is observed that the findings from the plain concrete are also valid for the reinforced concrete. However, for the reinforced concrete, the ER values are also affected by the presence of reinforcing steel and saturation of concrete, which could cause disruptions in ER measurements


Sign in / Sign up

Export Citation Format

Share Document