The effect of enamel moisture on tensile bond strength of composite resin using Single bond in total etch technique

2014 ◽  
Vol 10 (1) ◽  
pp. 59-68
Author(s):  
H Afshar ◽  
M Ghandehari ◽  
S Amiri ◽  
Z Mirzayi ◽  
M Pourali ◽  
...  
2010 ◽  
Vol 22 (1) ◽  
Author(s):  
Selly Yusalina ◽  
Moch. Richata Fadil ◽  
Milly Armilia

Total etch adhesive system has been widely used in teeth conservation area as an adhesive agent before implicating composite resin restoration agent. The aim of this research is to prove the difference of tensile bond strength between total etch (Single Bond) and self etch adhesive system (Adper prompt L-Pop) on dentin surface in vitro. The extracted and non carries maxillary premolar teeth were used in this research and were divided into 2 groups. The first group comprised 15 specimen teeth etched in phosphoric acid and was applicated with the Single Bond adhesive agent. The second group comprised 15 specimen teeth, applicated with the Adper Prompt-L-Pop. The composite resin (Z 350, 3M) was applied incrementally and each of the layers was rayed for 20 seconds. The specimens were stored in physiologic solution before they were tested. Tensile bond strength was measured by LRX Plus Lloyd Instrument, with 1 N load and 1 mm/minute speed, and the measurement result was in Mpa unit. The result was evaluated statistically by the Student t-test with α = 0.05. Single Bond (the 5th generation) showed a better bond strength compared to the Adper Prompt-L-Pop (the 6th generation).


2007 ◽  
Vol 21 (1) ◽  
pp. 81-86 ◽  
Author(s):  
Alexandre Henrique Susin ◽  
Walison Arthuso Vasconcellos ◽  
José Roberto Cury Saad ◽  
Osmir Batista de Oliveira Junior

The use of acid etchants to produce surface demineralization and collagen network exposure, allowing adhesive monomers interdiffusion and consequently the formation of a hybrid layer, has been considered the most efficient mechanism of dentin bonding. The aim of this study was to compare the tensile bond strength to dentin of three adhesive systems, two self-etching ones (Clearfil SE Bond - CSEB and One Up Bond F - OUBF) and one total-etching one (Single Bond - SB), under three dentinal substrate conditions (wet, dry and re-wet). Ninety human, freshly extracted third molars were sectioned at the occlusal surface to remove enamel and to form a flat dentin wall. The specimens were restored with composite resin (Filtek Z250) and submitted to tensile bond strength testing (TBS) in an MTS 810. The data were submitted to two-way ANOVA and Tukey's test (p = 0.05). Wet dentin presented the highest TBS values for SB and CSEB. Dry dentin and re-wet produced significantly lower TBS values when using SB. OUBF was not affected by the different conditions of the dentin substrate, producing similar TBS values regardless of the surface pretreatments.


2007 ◽  
Vol 18 (2) ◽  
pp. 124-128 ◽  
Author(s):  
Wanessa Christine Souza-Zaroni ◽  
Letícia Caliento Seixas ◽  
Juliane Cristina Ciccone-Nogueira ◽  
Daniela Thomazatti Chimello ◽  
Regina Guenka Palma-Dibb

The aim of this study was to assess the tensile bond strength of four adhesive systems to enamel and dentin: Clearfil Liner Bond 2V - C, Prime&Bond NT/NRC - PB, Single Bond - SB and All Bond 2 -AB. For such purpose, 40 sound human molars were selected. Crowns were bisected in a mesiodistal direction and each half was ground until flat enamel (E) or dentin (D) surfaces were obtained. A total of 80 specimens were randomly assigned to 4 groups (n=20, 10 in enamel and 10 in dentin). After surface treatment, a composite resin (Z250; 3M) cone was prepared using a split Teflon® matrix. Bond strength was tested in an universal testing machine (0.5 mm/min). Bond strength means in MPa were: C - E: 18.66 (±2.67) and D: 21.62 (±5.29); PB - E: 18.13 (±2.96) and D: 3.19 (±1.40); SB - E: 20.06 (±6.11) and D: 16.95 (±2.57); AB - E: 18.20 (±3.94) and D: 15.94 (±4.72). Statistical analysis of data by two-way ANOVA showed that C presented the best results followed by SB. In conclusion, among the tested materials, Clearfil Liner Bond 2V self-etching primer adhesive syetem had the best performance. The substrate type influenced bond strength, being higher to enamel.


2004 ◽  
Vol 12 (1) ◽  
pp. 45-50 ◽  
Author(s):  
Carlos José Soares ◽  
Marcelo Giannini ◽  
Marcelo Tavares de Oliveira ◽  
Luis Alexandre Maffei Sartini Paulillo ◽  
Luis Roberto Marcondes Martins

The purpose of this study was to evaluate the influence of different surface treatments on composite resin on the microtensile bond strength to a luting resin cement. Two laboratory composites for indirect restorations, Solidex and Targis, and a conventional composite, Filtek Z250, were tested. Forty-eight composite resin blocks (5.0 x 5.0 x 5.0mm) were incrementally manufactured, which were randomly divided into six groups, according to the surface treatments: 1- control, 600-grit SiC paper (C); 2- silane priming (SI); 3- sandblasting with 50 mm Al2O3 for 10s (SA); 4- etching with 10% hydrofluoric acid for 60 s (HF); 5- HF + SI; 6 - SA + SI. Composite blocks submitted to similar surface treatments were bonded together with the resin adhesive Single Bond and Rely X luting composite. A 500-g load was applied for 5 minutes and the samples were light-cured for 40s. The bonded blocks were serially sectioned into 3 slabs with 0.9mm of thickness perpendicularly to the bonded interface (n = 12). Slabs were trimmed to a dumbbell shape and tested in tension at 0.5mm/min. For all composites tested, the application of a silane primer after sandblasting provided the highest bond strength means.


2003 ◽  
Vol 27 (1) ◽  
pp. 35-39 ◽  
Author(s):  
Silvia Pithan ◽  
Ricardo de Sousa Vieira ◽  
Marcelo Carvalho Chain

The aim of this study was to measure in vitro; the tensile bond strength of three intracanal posts used in anterior primary teeth. A total of 45 single rooted primary anterior teeth were selected for the study and the crowns sectioned leaving 1mm above the cement-enamel junction. The roots were then assigned to three groups according the type of retention used. All roots were endodonticaly treated, a 4-mm of the canal was cleansed and a base of glass ionomer cement was put at the bottom of the prepared canal. The roots were then prepared to receive intracanal posts using a # 4137 diamond bur (KG Sorensen) used in a depth of 3-mm of the length of the canal. All the prepared roots were acid etched with a 37% phosphoric acid gel for 15 seconds, rinsed, dried and the dentin adhesive Single Bond (3M) was applied. Group I received intracanal posts and cores made of composite resin (Filtek Z 250, 3M). Group II intracanal posts were made from a 0.6mm orthodontic wire bent as a Greek letter type (gamma), fixed with the Z 250 composite resin and cores were built with the same composite. Finally Group III received intracanal retention made of a fiber glass post (Fibrekor Post, Generic/Pentron) with 1.25mm diameter, fixed with Z 250 and cores were made like the other groups. The samples were submitted to tension in a universal- testing machine (Instron, model 4444). Statistical analysis (ANOVA) reveled that there were no statistically significant differences between the groups. On the basis of the results of this in vitro study it was concluded that the type of intracanal post did not interfere with the tensile strength and the most frequent type of failure was of adhesive type, corresponding to 74% of the sample.


2020 ◽  
Vol 10 (6) ◽  
pp. 6688-6694

The present study aimed to compare the micro-tensile bond strength of new and conventional glass-ionomers and Z350 flowable composite resin to sound and caries-affected dentin. Eighty extracted third molars were selected. Standard Cl I cavities were prepared on occlusal surfaces. Forty teeth were assigned to the sound tooth group, and in the remaining 40 teeth, carious lesions were produced using a laboratory technique. Then each group (n=40) was subdivided into 5 groups (n=8) in terms of the restorative material used (EQUIA® Forte, Ketac Molar, encapsulated and hand-mixed GC Fuji II LC glass-ionomers and Z350 flowable composite resin). The cavities were restored. The highest micro-tensile bond strength was recorded with Z350 flowable composite resin in sound dentin (29.65), and the lowest was recorded with GC Fuji II LC (powder, liquid) in affected dentin (7.88). Significant differences were detected in the micro-tensile bond strength between the 5 restorative material groups. The composite resin bond strength was the maximum and was significantly different from all the other groups. The micro-tensile bond strength was affected by the type of dentin; in this context, in all the restorative groups, the bond strength in sound dentin was significantly higher than that in affected dentin. The most frequent failure mode was adhesive in the sound and affected dentin.


2021 ◽  
Vol 10 (40) ◽  
pp. 33-37
Author(s):  
Joyce de Figueiredo Meira Barbosa ◽  
Lara Pepita de Souza Oliveira ◽  
Marcelo Nascimento Bruce ◽  
Jonas Alves Oliveira ◽  
Ligia Regina Mota Vasconcelos ◽  
...  

Acrylic denture teeth may suffer fracture or wear requiring the need for repair. This study aimed to evaluate the shear bond strength between acrylic resin artificial teeth restored with composite resin (with two different surface treatments) and acrylic resin (AR), simulating repair with these materials. Thirty artificial incisors were included by the palatal side in a circular microwave-polymerized AR base and polished on their buccal side with 120 and 320 grit sandpaper in a metallographic polisher and, then, divided into three groups: (I) restoration with self-cured AR; (II) conventional restoration with Z-100 composite resin with application of acid etching and Single Bond-3M adhesive; and (III) restoration with Z-100 composite resin with submersion for 30 seconds in acetone and application of Single Bond-3M adhesive. Shear bond strength tests were performed in a Universal Testing Machine (Instron). The results were submitted to ANOVA and Tukey (p<0.05) tests, in which Group I (33.26MPa ±10.76) and Group III (22.24MPa ±13.13) showed no statistically significant difference, but both were superior to Group II (10.31MPa ±5.62), which showed a lower value of shear bond strength. It can be concluded that composite resin restoration with acetone pretreatment can be a viable alternative for repair.


2021 ◽  
Vol 31 (2) ◽  
pp. 58-67
Author(s):  
Xiangyu WANG ◽  
Naohiro IWATA ◽  
Kenzo YASUO ◽  
Kazushi YOSHIKAWA ◽  
Kazuyo YAMAMOTO

Sign in / Sign up

Export Citation Format

Share Document