Sensitive absorbance measurement in droplet microfluidics via multipass flow cells

Author(s):  
Bingyuan Lu ◽  
Adrian Nightingale ◽  
Xize Niu
RSC Advances ◽  
2020 ◽  
Vol 10 (51) ◽  
pp. 30975-30981
Author(s):  
Adrian M. Nightingale ◽  
Sammer-ul Hassan ◽  
Kyriacos Makris ◽  
Wahida T. Bhuiyan ◽  
Terry J. Harvey ◽  
...  

We present a widely accessible method for fabricating monolithic fluoropolymer microfluidic chips, which allows droplet absorbance measurement over multi-month periods.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kanako Saito ◽  
Yuri Ota ◽  
Dieter M. Tourlousse ◽  
Satoko Matsukura ◽  
Hirotsugu Fujitani ◽  
...  

AbstractDroplet microfluidics has emerged as a powerful technology for improving the culturing efficiency of environmental microorganisms. However, its widespread adoption has been limited due to considerable technical challenges, especially related to identification and manipulation of individual growth-positive droplets. Here, we combined microfluidic droplet technology with on-chip “fluorescent nucleic acid probe in droplets for bacterial sorting” (FNAP-sort) for recovery of growth-positive droplets and droplet microdispensing to establish an end-to-end workflow for isolation and culturing of environmental microbes. As a proof-of-concept, we demonstrate the ability of our technique to yield high-purity cultures of rare microorganisms from a representative complex environmental microbiome. As our system employs off-the-shelf commercially available equipment, we believe that it can be readily adopted by others and may thus find widespread use toward culturing the high proportion of as-of-yet uncultured microorganisms in different biomes.


Author(s):  
Kevin Krause ◽  
ChungHyuk Lee ◽  
Jason K. Lee ◽  
Kieran F. Fahy ◽  
Hisan W. Shafaque ◽  
...  

Micromachines ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 272
Author(s):  
Doojin Lee ◽  
Amy Q. Shen

Droplet microfluidics provides a versatile tool for measuring interfacial tensions between two immiscible fluids owing to its abilities of fast response, enhanced throughput, portability and easy manipulations of fluid compositions, comparing to conventional techniques. Purely homogeneous extension in the microfluidic device is desirable to measure the interfacial tension because the flow field enables symmetric droplet deformation along the outflow direction. To do so, we designed a microfluidic device consisting of a droplet production region to first generate emulsion droplets at a flow-focusing area. The droplets are then trapped at a stagnation point in the cross junction area, subsequently being stretched along the outflow direction under the extensional flow. These droplets in the device are either confined or unconfined in the channel walls depending on the channel height, which yields different droplet deformations. To calculate the interfacial tension for confined and unconfined droplet cases, quasi-static 2D Darcy approximation model and quasi-static 3D small deformation model are used. For the confined droplet case under the extensional flow, an effective viscosity of the two immiscible fluids, accounting for the viscosity ratio of continuous and dispersed phases, captures the droplet deformation well. However, the 2D model is limited to the case where the droplet is confined in the channel walls and deforms two-dimensionally. For the unconfined droplet case, the 3D model provides more robust estimates than the 2D model. We demonstrate that both 2D and 3D models provide good interfacial tension measurements under quasi-static extensional flows in comparison with the conventional pendant drop method.


2021 ◽  
pp. 2000123
Author(s):  
Pantelitsa Dimitriou ◽  
Jin Li ◽  
Giusy Tornillo ◽  
Thomas McCloy ◽  
David Barrow

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Johannes G. Keller ◽  
Uschi M. Graham ◽  
Johanna Koltermann-Jülly ◽  
Robert Gelein ◽  
Lan Ma-Hock ◽  
...  

An amendment to this paper has been published and can be accessed via a link at the top of the paper.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Chen Peng ◽  
Gan Luo ◽  
Junbo Zhang ◽  
Menghuan Chen ◽  
Zhiqiang Wang ◽  
...  

AbstractElectrochemical CO2 reduction can produce valuable products with high energy densities but the process is plagued by poor selectivities and low yields. Propanol represents a challenging product to obtain due to the complicated C3 forming mechanism that requires both stabilization of *C2 intermediates and subsequent C1–C2 coupling. Herein, density function theory calculations revealed that double sulfur vacancies formed on hexagonal copper sulfide can feature as efficient electrocatalytic centers for stabilizing both CO* and OCCO* dimer, and further CO–OCCO coupling to form C3 species, which cannot be realized on CuS with single or no sulfur vacancies. The double sulfur vacancies were then experimentally synthesized by an electrochemical lithium tuning strategy, during which the density of sulfur vacancies was well-tuned by the charge/discharge cycle number. The double sulfur vacancy-rich CuS catalyst exhibited a Faradaic efficiency toward n-propanol of 15.4 ± 1% at −1.05 V versus reversible hydrogen electrode in H-cells, and a high partial current density of 9.9 mA cm−2 at −0.85 V in flow-cells, comparable to the best reported electrochemical CO2 reduction toward n-propanol. Our work suggests an attractive approach to create anion vacancy pairs as catalytic centers for multi-carbon-products.


Author(s):  
Jianhua Yang ◽  
Ran Tu ◽  
Huiling Yuan ◽  
Qinhong Wang ◽  
Leilei Zhu

Sign in / Sign up

Export Citation Format

Share Document