scholarly journals Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms

2021 ◽  
pp. jnumed.120.256719
Author(s):  
Lukas M Carter ◽  
Chansoo Choi ◽  
Simone Krebs ◽  
Bradley Jay Beattie ◽  
Chan Hyeong Kim ◽  
...  
Keyword(s):  
2011 ◽  
Vol 38 (6Part34) ◽  
pp. 3843-3843
Author(s):  
R Fisher ◽  
D Hintenlang ◽  
M Arreola

2007 ◽  
Vol 48 (12) ◽  
pp. 1951-1960 ◽  
Author(s):  
G. El Fakhri ◽  
P. A. Santos ◽  
R. D. Badawi ◽  
C. H. Holdsworth ◽  
A. D. Van Den Abbeele ◽  
...  

2009 ◽  
Vol 36 (3) ◽  
pp. 993-1007 ◽  
Author(s):  
Willi A. Kalender ◽  
Paul Deak ◽  
Markus Kellermeier ◽  
Marcel van Straten ◽  
Sabrina V. Vollmar
Keyword(s):  
X Ray ◽  

Author(s):  
M. A. Listvan ◽  
R. P. Andres

Knowledge of the function and structure of small metal clusters is one goal of research in catalysis. One important experimental parameter is cluster size. Ideally, one would like to produce metal clusters of regulated size in order to characterize size-dependent cluster properties.A source has been developed which is capable of producing microscopic metal clusters of controllable size (in the range 5-500 atoms) This source, the Multiple Expansion Cluster Source, with a Free Jet Deceleration Filter (MECS/FJDF) operates as follows. The bulk metal is heated in an oven to give controlled concentrations of monomer and dimer which were expanded sonically. These metal species were quenched and condensed in He and filtered to produce areosol particles of a controlled size as verified by mass spectrometer measurements. The clusters were caught on pre-mounted, clean carbon films. The grids were then transferred in air for microscopic examination. MECS/FJDF was used to produce two different sizes of silver clusters for this study: nominally Ag6 and Ag50.


Author(s):  
Lawrence W. Ortiz ◽  
Bonnie L. Isom

A procedure is described for the quantitative transfer of fibers and particulates collected on membrane filters to electron microscope (EM) grids. Various Millipore MF filters (Millipore AA, HA, GS, and VM; 0.8, 0.45, 0.22 and 0.05 μm mean pore size) have been used with success. Observed particle losses have not been size dependent and have not exceeded 10%. With fibers (glass or asbestos) as the collected media this observed loss is approximately 3%.


2020 ◽  
Vol 64 (2) ◽  
pp. 383-396
Author(s):  
Lara K. Krüger ◽  
Phong T. Tran

Abstract The mitotic spindle robustly scales with cell size in a plethora of different organisms. During development and throughout evolution, the spindle adjusts to cell size in metazoans and yeast in order to ensure faithful chromosome separation. Spindle adjustment to cell size occurs by the scaling of spindle length, spindle shape and the velocity of spindle assembly and elongation. Different mechanisms, depending on spindle structure and organism, account for these scaling relationships. The limited availability of critical spindle components, protein gradients, sequestration of spindle components, or post-translational modification and differential expression levels have been implicated in the regulation of spindle length and the spindle assembly/elongation velocity in a cell size-dependent manner. In this review, we will discuss the phenomenon and mechanisms of spindle length, spindle shape and spindle elongation velocity scaling with cell size.


1977 ◽  
Vol 38 (C1) ◽  
pp. C1-267-C1-269 ◽  
Author(s):  
C. M. SRIVASTAVA ◽  
M. J. PATNI ◽  
N. G. NANADIKAR
Keyword(s):  

2019 ◽  
Vol 58 (05) ◽  
pp. 371-378
Author(s):  
Alfred O. Ankrah ◽  
Ismaheel O. Lawal ◽  
Tebatso M.G. Boshomane ◽  
Hans C. Klein ◽  
Thomas Ebenhan ◽  
...  

Abstract 18F-FDG and 68Ga-citrate PET/CT have both been shown to be useful in the management of tuberculosis (TB). We compared the abnormal PET findings of 18F-FDG- and 68Ga-citrate-PET/CT in patients with TB. Methods Patients with TB on anti-TB therapy were included. Patients had a set of PET scans consisting of both 18F-FDG and 68Ga-citrate. Abnormal lesions were identified, and the two sets of scans were compared. The scan findings were correlated to the clinical data as provided by the attending physician. Results 46 PET/CT scans were performed in 18 patients, 11 (61 %) were female, and the mean age was 35.7 ± 13.5 years. Five patients also had both studies for follow-up reasons during the use of anti-TB therapy. Thirteen patients were co-infected with HIV. 18F-FDG detected more lesions than 68Ga-citrate (261 vs. 166, p < 0.0001). 68Ga-citrate showed a better definition of intracerebral lesions due to the absence of tracer uptake in the brain. The mean SUVmax was higher for 18F-FDG compared to 68Ga-citrate (5.73 vs. 3.01, p < 0.0001). We found a significant correlation between the SUVmax of lesions that were determined by both tracers (r = 0.4968, p < 0.0001). Conclusion Preliminary data shows 18F-FDG-PET detects more abnormal lesions in TB compared to 68Ga-citrate. However, 68Ga-citrate has better lesion definition in the brain and is therefore especially useful when intracranial TB is suspected.


Sign in / Sign up

Export Citation Format

Share Document