scholarly journals A Camera Distortion Model Calibration Method Based on Fixed Points

Author(s):  
Q.M. Liu ◽  
L. Zhang ◽  
X. Wu ◽  
X. Li
Author(s):  
J. Sebastian Hernandez-Suarez ◽  
A. Pouyan Nejadhashemi ◽  
Kalyanmoy Deb

Author(s):  
Junwoo Jason Son ◽  
Youngbin Son ◽  
Byeongho Song ◽  
Soohee Han

2015 ◽  
Vol 35 (6) ◽  
pp. 0615001 ◽  
Author(s):  
张敏 Zhang Min ◽  
金龙旭 Jin Longxu ◽  
李国宁 Li Guoning ◽  
武奕楠 Wu Yinan ◽  
韩双丽 Han Shuangli

Sensors ◽  
2020 ◽  
Vol 20 (20) ◽  
pp. 5934
Author(s):  
Xiao Li ◽  
Wei Li ◽  
Xin’an Yuan ◽  
Xiaokang Yin ◽  
Xin Ma

Lens distortion is closely related to the spatial position of depth of field (DoF), especially in close-range photography. The accurate characterization and precise calibration of DoF-dependent distortion are very important to improve the accuracy of close-range vision measurements. In this paper, to meet the need of short-distance and small-focal-length photography, a DoF-dependent and equal-partition based lens distortion modeling and calibration method is proposed. Firstly, considering the direction along the optical axis, a DoF-dependent yet focusing-state-independent distortion model is proposed. By this method, manual adjustment of the focus and zoom rings is avoided, thus eliminating human errors. Secondly, considering the direction perpendicular to the optical axis, to solve the problem of insufficient distortion representations caused by using only one set of coefficients, a 2D-to-3D equal-increment partitioning method for lens distortion is proposed. Accurate characterization of DoF-dependent distortion is thus realized by fusing the distortion partitioning method and the DoF distortion model. Lastly, a calibration control field is designed. After extracting line segments within a partition, the de-coupling calibration of distortion parameters and other camera model parameters is realized. Experiment results shows that the maximum/average projection and angular reconstruction errors of equal-increment partition based DoF distortion model are 0.11 pixels/0.05 pixels and 0.013°/0.011°, respectively. This demonstrates the validity of the lens distortion model and calibration method proposed in this paper.


2011 ◽  
Vol 230-232 ◽  
pp. 723-727 ◽  
Author(s):  
Bao Feng Zhang ◽  
Xiu Zhen Tian ◽  
Xiao Ling Zhang

In order to simplify previous camera calibration method, this paper put forward an easy camera calibration method based on plane grid points on the foundation of Heikkila plane model calibration method. Intrinsic and extrinsic parameters of the camera are calibrated with MATLAB, then the rotation matrix and the translation vector are calculated. The experiment results show this method is not only simple in practice, but also can meet the needs of computer vision systems.


2017 ◽  
Vol 12 (4) ◽  
Author(s):  
Yousheng Chen ◽  
Andreas Linderholt ◽  
Thomas J. S. Abrahamsson

Correlation and calibration using test data are natural ingredients in the process of validating computational models. Model calibration for the important subclass of nonlinear systems which consists of structures dominated by linear behavior with the presence of local nonlinear effects is studied in this work. The experimental validation of a nonlinear model calibration method is conducted using a replica of the École Centrale de Lyon (ECL) nonlinear benchmark test setup. The calibration method is based on the selection of uncertain model parameters and the data that form the calibration metric together with an efficient optimization routine. The parameterization is chosen so that the expected covariances of the parameter estimates are made small. To obtain informative data, the excitation force is designed to be multisinusoidal and the resulting steady-state multiharmonic frequency response data are measured. To shorten the optimization time, plausible starting seed candidates are selected using the Latin hypercube sampling method. The candidate parameter set giving the smallest deviation to the test data is used as a starting point for an iterative search for a calibration solution. The model calibration is conducted by minimizing the deviations between the measured steady-state multiharmonic frequency response data and the analytical counterparts that are calculated using the multiharmonic balance method. The resulting calibrated model's output corresponds well with the measured responses.


2018 ◽  
Vol 1087 ◽  
pp. 052021
Author(s):  
Bo Qu ◽  
Xiaofei Sun ◽  
Ruonan Sun ◽  
Xinhe Zhang ◽  
Wei Huang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document